The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Wear Characteristics of Metallic Biomaterials: A Review
Open accessAbstract
Metals are extensively used in a variety of applications in the medical field for internal support and biological tissue replacements, such as joint replacements, dental roots, orthopedic fixation, and stents. The metals and alloys that are primarily used in biomedical applications are stainless steels, Co alloys, and Ti alloys. The service period of a metallic biomaterial is determined by its abrasion and wear resistance. A reduction in the wear resistance of the implant results in the release of incompatible metal ions into the body that loosen the implant. In addition, several reactions may occur because of the deposition of wear debris in tissue. Therefore, developing biomaterials with high wear resistance is critical to ensuring a long life for the biomaterial. The aim of this work is to review the current state of knowledge of the wear of metallic biomaterials and how wear is affected by the material properties and conditions in terms of the type of alloys developed and fabrication processes. We also present a brief evaluation of various experimental test techniques and wear characterization techniques that are used to determine the tribological performance of metallic biomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Osseointegration and its experimental background
Branemark, P.-I. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(83)80101-2 · Cited by 2,084
Recent metallic materials for biomedical applications
Niinomi, M. (2002) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-002-0109-2 · Cited by 1,508
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Comparison of metal release from various metallic biomaterials in vitro
Okazaki, Y., & Gotoh, E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.005 · Cited by 862
Handbook of Biomaterial Properties
(1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9 · Cited by 639
Fatigue of biomaterials: a review
Teoh, S. (2000) · International Journal of Fatigue · doi:10.1016/s0142-1123(00)00052-9 · Cited by 446
Ratner, B. D., Hoffman, A. S., Schoen, F. J., & Lemons, J. E. (1996) · Biomaterials Science · doi:10.1016/b978-012582460-6/50002-5 · Cited by 385
Niinomi, M. (2008) · Journal of Artificial Organs · doi:10.1007/s10047-008-0422-7 · Cited by 295
Cited by
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Human cells with osteogenic potential in bone tissue research
Dvorakova, J., Wiesnerova, L., Chocholata, P., Kulda, V., Landsmann, L., Cedikova, M., Kripnerova, M., Eberlova, L., & Babuska, V. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01096-w · Cited by 58
Metadata
- Authors
- Hussein, M., Mohammed, A., & Al-Aqeeli, N.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2015-05-21
- Volume
- 8
- Issue
- 5
- Pages
- 2749-2768
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2099525796
- Cited by
- 286
- References
- 18
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wear Characteristics of Metallic Biomaterials: A Review. https://app.cochat.ai/papers/10.3390/ma8052749
- The paper
- Hussein, M., Mohammed, A., & Al-Aqeeli, N. (2015). Wear Characteristics of Metallic Biomaterials: A Review. Materials. https://doi.org/10.3390/ma8052749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.