Microfluidic-Based 3D Engineered Microvascular Networks and Their Applications in Vascularized Microtumor Models
Open accessAbstract
The microvasculature plays a critical role in human physiology and is closely associated to various human diseases. By combining advanced microfluidic-based techniques, the engineered 3D microvascular network model provides a precise and reproducible platform to study the microvasculature in vitro, which is an essential and primary component to engineer organ-on-chips and achieve greater biological relevance. In this review, we discuss current strategies to engineer microvessels in vitro, which can be broadly classified into endothelial cell lining-based methods, vasculogenesis and angiogenesis-based methods, and hybrid methods. By closely simulating relevant factors found in vivo such as biomechanical, biochemical, and biological microenvironment, it is possible to create more accurate organ-specific models, including both healthy and pathological vascularized microtissue with their respective vascular barrier properties. We further discuss the integration of tumor cells/spheroids into the engineered microvascular to model the vascularized microtumor tissue, and their potential application in the study of cancer metastasis and anti-cancer drug screening. Finally, we conclude with our commentaries on current progress and future perspective of on-chip vascularization techniques for fundamental and clinical/translational research.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Organ-on-a-chip technology has been used to construct a microvascular system with selective barrier function similar to that in the body to simulate the microstructure and microphysiological functions of human organs.
“Researchers have used organ-on-a-chip technology to construct a microvascular system with selective barrier function similar to that in the body to simulate the microstructure and microphysiological functions of human organs to better describe organ functions and characteristics179.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [179]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 143 · Cited by 106
- Authors
- Wang, X., Sun, Q., & Pei, J.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Wang, Xiaolin
- ORCID
- Wang, Xiaolin
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2018-09-27
- Volume
- 9
- Issue
- 10
- Pages
- 493
- ISSN
- 2072-666X (ISSN-L)
- PMC
- PMC6215090
- OpenAlex
- W2894433240
- Cited by
- 106
- References
- 143
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 17 · 2023: 6 · 2022: 14 · 2021: 25 · 2020: 20 · 2019: 11
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Micromachines (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (31600781)
- Science and Technology Commission of Shanghai Municipality (17JC1400200)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- organ-on-a-chip, vasculogenesis, angiogenesis, tumor spheroids, metastasis, anticancer drug screening, microcirculation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review