Solvent Bar Micro-Extraction of Heavy Metals from Natural Water Samples Using 3-Hydroxy-2-Naphthoate-Based Ionic Liquids
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Developments in the liquid micro-extraction of trace metals from aqueous phases have proven to be limited when extended from pure water to more complex and demanding matrices such as sea water or wastewater treatment effluents. To establish a system that works under such matrices, we successfully tested three task-specific ionic liquids, namely trihexyltetradecyl- phosphonium-, methyltrioctylphosphonium- and methyltrioctylammonium 3-hydroxy-2-naphthoate in two-phase solvent bar micro-extraction (SBME) experiments. We describe the influence of pH, organic additives, time, stirring rate and volume of ionic liquid for multi-elemental micro-extraction of Cu, Ag, Cd and Pb from various synthetic and natural aqueous feed solutions. Highest extraction for all metals was achieved at pH 8.0. Minimal leaching of the ionic liquids into the aqueous phase was demonstrated, with values < 30 mg L−1 DOC in all cases. Sample salinities of up to 60 g L−1 NaCl had a positive effect on the extraction of Cd, possibly due to an efficient extraction mechanism of the present chlorido complexes. In metal-spiked natural feed solutions, the selected SBME setups showed unchanged stability under all conditions tested. We could efficiently (≥85%) extract Cu and Ag from drinking water and achieved high efficacies for Ag and Cd from natural sea water and hypersaline water, respectively. The method presented here proves to be a useful tool for an efficient SBME of heavy metals from natural waters without the need to pretreat or modify the sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Effects of (a) adding dodecan-1-ol at pH 8.0 and (b) the pH using pure [P66614][HNA] on extraction efficacy and leaching for an extraction time of 2 h (n = 3, error bars = ± SD).](https://figures.cochat.ai/paper-figures/9f2363eba04647ffbc99a243778aea2e/solvent-bar-micro-extraction-of-heavy-metals-from-natural-water-samples-using-3-figure-1.jpg)
![Figure 2 Time dependence of extraction and leaching using 50 wt % dodecan-1-ol (DdOH) mixtures of [P1888][HNA] and [N1888][HNA], respectively, pH = 8.0 (n = 3, error bars = ± SD).](https://figures.cochat.ai/paper-figures/71d5b27fe17343a08a09de4041c4a18f/solvent-bar-micro-extraction-of-heavy-metals-from-natural-water-samples-using-3-figure-2.jpg)
![Figure 3 Effect of NaCl on extraction efficacy of solvent bars containing pure [P66614][HNA] at pH 8.0 for an extraction time of 2 h (n = 3, error bars = ± SD).](https://figures.cochat.ai/paper-figures/01d2b89f4e4844b1b472e1940cb98a6c/solvent-bar-micro-extraction-of-heavy-metals-from-natural-water-samples-using-3-figure-3.jpg)
![Figure 4 Extraction efficacies of the SBME setups using pure [P66614][HNA] and the two respective 50 wt % dodecan-1-ol mixtures of [P1888][HNA] and [N1888][HNA] in natural water feed solutions for an extraction time of 2 h (n = 3, error bars = ± SD).](https://figures.cochat.ai/paper-figures/5e4755ef7cf747158679b3138889e1ad/solvent-bar-micro-extraction-of-heavy-metals-from-natural-water-samples-using-3-figure-4.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, Pirkwieser et al. evaluated the potential of three ILs containing 3-hydroxy-2-naphtoate ([HNA]) anion and three cations: trihexyltetradecylphosphonium ([P 66614 ]), methyltrioc tylphosphonium ([P 1888 ]), and methyltrioctylammonium ([N 1888 ]), observing that extraction with [P 66614 ] was less sensitive to sample matrix of sea and salt-works water than with [P 1888 ] and [N 1888 ], in”
From Advances in ionic liquids and deep eutectic solvents-based liquid phase microextraction of metals for sample preparation in Environmental Analytical Chemistry (2021) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In this case, ILs containing methyltrioctylphosphonium and methyltrioctylammonium cations showed to be sensitive to the saline matrix, offering poor results in seawater, while trihexyltetradecylphosphonium based IL kept the same efficiency as in non-saline samples [27].”
From Advances in ionic liquids and deep eutectic solvents-based liquid phase microextraction of metals for sample preparation in Environmental Analytical Chemistry (2021) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Pb, Cu, Cd, and Ag were selectively extracted with ILs based on 3hydroxy-2-naphtoate anion.”
From Advances in ionic liquids and deep eutectic solvents-based liquid phase microextraction of metals for sample preparation in Environmental Analytical Chemistry (2021) · cites this paper as [27]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silver nanoparticle applications and human health
Ahamed, M., AlSalhi, M. S., & Siddiqui, M. K. J. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.08.016 · Cited by 1,298
Task-specific ionic liquids for the extraction of metal ions from aqueous solutions
Visser, A. E., Swatloski, R. P., Reichert, W. M., Davis Jr., J. H., Rogers, R. D., Mayton, R., Sheff, S., & Wierzbicki, A. (2001) · Chemical Communications · doi:10.1039/b008041l · Cited by 920
Use of ionic liquids as ‘green’ solvents for extractions
Zhao, H., Xia, S., & Ma, P. (2005) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1333 · Cited by 873
Are Ionic Liquids Chemically Stable?
Wang, B., Qin, L., Mu, T., Xue, Z., & Gao, G. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00594 · Cited by 665
Sorption of metals on humic acid
Kerndorff, H., & Schnitzer, M. (1980) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(80)90221-5 · Cited by 493
The influence of temperature and pH on trace metal speciation in seawater
Byrne, R. H., Kump, L. R., & Cantrell, K. J. (1988) · Marine Chemistry · doi:10.1016/0304-4203(88)90062-x · Cited by 364
Mutual Solubilities of Water and the [Cnmim][Tf2N] Hydrophobic Ionic Liquids
Freire, M. G., Carvalho, P. J., Gardas, R. L., Marrucho, I. M., Santos, L. M. N. B. F., & Coutinho, J. A. P. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp7097203 · Cited by 358
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305 · cited 1×
“Several studies have incorporated micro-extraction approaches, highlighting liquid- or solid-phase micro-extraction setups for trace metals [7,8].”
BackgroundDietz, M. L., Dzielawa, J. A., Laszak, I., Young, B. A., & Jensen, M. P. (2003) · Green Chem. · doi:10.1039/b310507p · Cited by 276
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Effects of Humic and Fulvic Acids on Silver Nanoparticle Stability, Dissolution, and Toxicity
Gunsolus, I. L., Mousavi, M. P. S., Hussein, K., Bühlmann, P., & Haynes, C. L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01496 · Cited by 249
Advances in solvent-microextraction techniques
Kokosa, J. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.09.020 · Cited by 225
State-of-the-art review on hollow fibre contactor technology and membrane-based extraction processes
Pabby, A. K., & Sastre, A. M. (2013) · Journal of Membrane Science · doi:10.1016/j.memsci.2012.11.060 · Cited by 219
Jiang, X., & Lee, H. K. (2004) · Analytical Chemistry · doi:10.1021/ac040069f · Cited by 217
Komjarova, I., & Blust, R. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.06.002 · Cited by 199
Salgado, A. (2003) · Journal of Power Sources · doi:10.1016/s0378-7753(03)00025-9 · Cited by 182
Egorov, V. M., Djigailo, D. I., Momotenko, D. S., Chernyshov, D. V., Torocheshnikova, I. I., Smirnova, S. V., & Pletnev, I. V. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.003 · Cited by 182
Ionic Liquids as Extracting Agents for Heavy Metals
Stojanovic, A., & Keppler, B. K. (2012) · Separation Science and Technology · doi:10.1080/01496395.2011.620587 · Cited by 173
Self-citationFischer, L., Falta, T., Koellensperger, G., Stojanovic, A., Kogelnig, D., Galanski, M. S., Krachler, R., Keppler, B. K., & Hann, S. (2011) · Water Research · doi:10.1016/j.watres.2011.06.011 · Cited by 172
Self-citationAbulhassani, J., Manzoori, J. L., & Amjadi, M. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.11.054 · Cited by 160
Modeling Adsorption of Copper(II), Cadmium(II) and Lead(II) on Purified Humic Acid
Liu, A., & Gonzalez, R. D. (2000) · Langmuir · doi:10.1021/la990607x · Cited by 132
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Metal extraction to ionic liquids: the relationship between structure, mechanism and application
Janssen, C. H. C., Macías-Ruvalcaba, N. A., Aguilar-Martínez, M., & Kobrak, M. N. (2015) · International Reviews in Physical Chemistry · doi:10.1080/0144235x.2015.1088217 · Cited by 114
Devi, N., Nathsarma, K. C., & Chakravortty, V. (2000) · Hydrometallurgy · doi:10.1016/s0304-386x(99)00054-7 · Cited by 113
Novel thiosalicylate-based ionic liquids for heavy metal extractions
Leyma, R., Platzer, S., Jirsa, F., Kandioller, W., Krachler, R., & Keppler, B. K. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.04.038 · Cited by 104
Self-citationPlatzer, S., Kar, M., Leyma, R., Chib, S., Roller, A., Jirsa, F., Krachler, R., MacFarlane, D. R., Kandioller, W., & Keppler, B. K. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.10.054 · Cited by 96
Self-citationMessadi, A., Mohamadou, A., Boudesocque, S., Dupont, L., & Guillon, E. (2013) · Separation and Purification Technology · doi:10.1016/j.seppur.2013.01.015 · Cited by 92
Recent Advances in Applications of Ionic Liquids in Miniaturized Microextraction Techniques
Kissoudi, M., & Samanidou, V. (2018) · Molecules · doi:10.3390/molecules23061437 · Cited by 86 · cited 1×
“Simultaneously, the unique physico-chemical properties of ILs drew interest for application in micro-extraction methods [20,21].”
BackgroundSastry, N. V., & Valand, M. K. (1996) · Journal of Chemical & Engineering Data · doi:10.1021/je9601725 · Cited by 80
Supported liquid membrane-based simultaneous separation of cadmium and lead from wastewater
Bhatluri, K. K., Manna, M. S., Saha, P., & Ghoshal, A. K. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.02.019 · Cited by 77
Rutkowska, M., Dubalska, K., Konieczka, P., & Namieśnik, J. (2014) · Molecules · doi:10.3390/molecules19067581 · Cited by 55
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50
Pirkwieser, P., López-López, J. A., Kandioller, W., Keppler, B. K., Moreno, C., & Jirsa, F. (2018) · Frontiers in Chemistry · doi:10.3389/fchem.2018.00172 · Cited by 50
Self-citationThioglycolate-based task-specific ionic liquids: Metal extraction abilities vs acute algal toxicity
Platzer, S., Leyma, R., Wolske, S., Kandioller, W., Heid, E., Schröder, C., Schagerl, M., Krachler, R., Jirsa, F., & Keppler, B. K. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.06.053 · Cited by 40
Self-citationChen, L., Chen, J., Li, H., Yang, M., Zou, D., Deng, Y., & Liu, Y. (2018) · Separation and Purification Technology · doi:10.1016/j.seppur.2018.06.042 · Cited by 40
Heavy metals in the mallard Anas platyrhynchos from eastern Austria
Plessl, C., Jandrisits, P., Krachler, R., et al. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.12.013 · Cited by 37
Novel Task Specific Ionic Liquids to Remove Heavy Metals from Aqueous Effluents
Diabate, P. D., Dupont, L., Boudesocque, S., et al. (2018) · Metals · doi:10.3390/met8060412 · Cited by 36
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.11.004 · Cited by 26
Self-citationIonic liquid based solvent micro-extraction of Ag and Cd from saline and hyper-saline waters
Herce-Sesa, B., López-López, J. A., Pinto, J. J., & Moreno, C. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.09.095 · Cited by 25
Self-citationPlatzer, S., Sap, O., Leyma, R., et al. (2014) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-014-3782-x · Cited by 23
López-López, J. A., Herce-Sesa, B., & Moreno, C. (2016) · Talanta · doi:10.1016/j.talanta.2016.06.018 · Cited by 23
Self-citationPinto, J. J., Martín, M., Herce-Sesa, B., López-López, J. A., & Moreno, C. (2015) · Talanta · doi:10.1016/j.talanta.2015.04.029 · Cited by 22
Self-citationLópez-López, J. A., Herce-Sesa, B., & Moreno, C. (2015) · Talanta · doi:10.1016/j.talanta.2014.09.030 · Cited by 18
Self-citationLópez-López, J. A., Pirkwieser, P., Leyma, R., Kandioller, W., Krachler, R., Keppler, B. K., Jirsa, F., & Moreno, C. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.08.008 · Cited by 18
Self-citationPoole, C. F. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.007 · Cited by 3
Herrmann, R. (1990) · CATENA · doi:10.1016/0341-8162(90)90032-9 · Cited by 2
Research works printed but not linked: 2
- Förstner, U., and Wittmann, G.T.W. (2012). Metal Pollution in the Aquatic Environment, Springer Science & Business Media. [2nd ed.].
- Barton, A.F. (2013). Alcohols with Water: Solubility Data Series, Elsevier.
Cited by
Abidli, A., Huang, Y., Ben Rejeb, Z., Zaoui, A., & Park, C. B. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.133102 · Cited by 194
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116398 · Cited by 86
Self-citationHerce-Sesa, B., Pirkwieser, P., López-López, J. A., Jirsa, F., & Moreno, C. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.121415 · Cited by 17
Self-citationPirkwieser, P., López-López, J. A., Schagerl, M., Kandioller, W., Keppler, B. K., Moreno, C., & Jirsa, F. (2020) · Applied Sciences · doi:10.3390/app10093157 · Cited by 13
“High extraction efficacies have been described at mg L−1 levels in liquid–liquid as well as in a solvent bar micro-extraction setup [28,34].”
BackgroundResultInfluentialSelf-citation
Metadata
- Authors
- Pirkwieser, P., López-López, J. A., Kandioller, W., Keppler, B. K., Moreno, C., & Jirsa, F.
- Affiliations
- University of Vienna (AT)
- Universidad de Cádiz (ES)
- Corresponding author
- Jirsa, Franz
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2018-11-17
- Volume
- 23
- Issue
- 11
- Pages
- 3011
- ISSN
- 1420-3049 (ISSN-L)
- PMC
- PMC6278406
- OpenAlex
- W2901348652
- Semantic Scholar
- cc81511207054a8bfdd4150a8a3c7287aebd521c
- Cited by
- 17
- References
- 47
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 3
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Molecules (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Phaidra (Universität Wien) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministerio de Economía, Industria y Competitividad, Gobierno de España (CTM-2013-47549-P)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
- Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
- Keywords
- heavy metals, task-specific ionic liquids, copper, silver, cadmium, lead, seawater, hypersaline water, drinking water, ionic liquid leaching, pH effect, organic additives
- MeSH terms
- Carboxylic Acids, Copper, Ions, Naphthalenes, Solvents, Water, Metals, Heavy, Ionic Liquids, Chemical Phenomena, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.