A Review of Design and Evaluation Practices in Mobile Text Entry for Visually Impaired and Blind Persons
Open accessThe DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index; 17 of the 65 sources its claims cite were checked for support.
Abstract
Millions of people with vision impairment or vision loss face considerable barriers in using mobile technology and services due to the difficulty of text entry. In this paper, we review related studies involving the design and evaluation of novel prototypes for mobile text entry for persons with vision loss or impairment. We identify the practices and standards of the research community and compare them against the practices in research for non-impaired persons. We find that there are significant shortcomings in the methodological and result-reporting practices in both population types. In highlighting these issues, we hope to inspire more and better quality research in the domain of mobile text entry for persons with and without vision impairment.
Overview
CoChat Summary
TL;DR
This scoping review analyzes 24 papers reporting 26 studies on mobile text entry for visually impaired and blind persons (VIBPs) and compares them with a matched sample of 26 studies on non-impaired users. It finds that VIBP research is mostly designer-led, lab-based, and sparsely reported, with similar methodological weaknesses also present in the comparison sample.
Key findings
- The VIBP literature set comprised 24 publications / 26 studies; the comparison set also contained 26 studies on non-impaired users.
- Design was predominantly designer-led: 19 studies, versus 2 user-led and 3 combination studies; the paper says only 3 VIBP studies used computational optimization, and only 5 discussed prototypes derived with input from VIBP participants.
- Evaluation studies with VIBPs involved 1 to 14 participants per study, with an average of 8.65; the comparison sample averaged 15.46 participants per study.
- For VIBP studies, the average number of reported metrics was 1.667; for non-impaired studies it was 3.038. For VIBP speed metrics, WPM was used in 61.5% of studies; for non-impaired studies, 84.6% used WPM.
Methods
- The paper is a scoping review guided by PRISMA concepts, using a three-stage process: planning, conducting, and analyzing.
- Search and screening: Google Scholar searches with nine query combinations (e.g., “mobile keyboard,” “mobile text entry,” “virtual keyboard” crossed with “low vision,” “blind,” “visually impaired”), limited to 2013 or later, with manual screening followed by an AI-assisted search tool (Research Rabbit).
- Data extraction covered prototype characteristics, design approach, participant counts, study design, tasks, metrics, and post-experiment methods; the VIBP set was contrasted with a randomly selected 26-study sample of recent non-impaired text-entry papers.
Limitations
- The authors state that the VIBP literature is scarce, and that two papers were excluded because paywalls prevented access.
- They included only peer-reviewed conference proceedings and journal articles, so dissertations were not considered; they also did not expand the search to older-adult text entry research.
- For the non-impaired comparison set, they used a small random sample of 26 studies from a larger body of work, so another sample might yield slightly different results. This is stated in the paper.
- Evident from the text: the review relies heavily on Google Scholar and first-page results plus AI-assisted discovery, so coverage may still miss some relevant studies despite the two-stage search process.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
16 Valid · 3 Not valid · 25 Not checked · 102 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Furthermore, we present findings from a wider body of research than previously examined (24 papers reporting a total of 26 studies, compared with 11 in [15], 16 in [16] and 19 in [17], which is the most recent work).”
What the sources say
- Not checked — no full text of the sourcecites [15] Siqueira, J., Soares, F., Ferreira, D.J., Silva, C.R.G., Silva, C.R.G., Berretta, L.d.O., Ferreira, C.B.R., Felix, I.M., Soares, A.d.S., and da Costa, R.M. (2016, January 10–14). Braille Text Entry on Smartphones: A Systematic Review of the Literature. Proceedings of the 2016 IEEE 40th Annual Computer Software and Applications Conference (COMPSAC), Atlanta, GA, USA. source
- Not checked — no full text of the sourcecites [16] Shahid, H., Ali Shah, M., Dar, B.K., and Fizzah, F. (2018, January 6–7). A Review of Smartphone’s Text Entry for Visually Impaired. Proceedings of the 2018 24th International Conference on Automation and Computing (ICAC), Newcastle upon Tyne, UK. source
- Partly supportedcites [17] Shokat, 2020, Analysis and Evaluation of Braille to Text Conversion Methods, Mob. Inf. Syst. sourceExperimental — accuracy not yet measured
Table 3 (section 5, page unavailable) numbers 19 touch-screen Braille input methods, ending with '19 Braille Ecran.' The Methodology describes selecting research papers, but our copy does not establish that those 19 methods represent 19 distinct papers or studies. The citation therefore supports the figure of 19 methods, not the precise comparison of study counts. (LLM, conf=0.83)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Participant numbers ranged from as low as 2 [44] to up to 13 participants [38].”
What the sources say
- Supportedcites [44] Buzzi, M.C., Buzzi, M., Leporini, B., and Trujillo, A. (2014, January 20–22). Designing a Text Entry Multimodal Keypad for Blind Users of Touchscreen Mobile Phones. Proceedings of the 16th International ACM SIGACCESS Conference on Computers & Accessibility—ASSETS ’14, Rochester, NY, USA. source
The citation is attached to the lower endpoint, two participants, not the upper endpoint of 13. Section 6.1 (Preliminary Assessment) states that two blind participants evaluated the prototype in an early usability test. The paper separately reports 14 recruits for its later pilot test in Section 6.2.1. (LLM, conf=0.94)
- Not checked — no full text of the sourcecites [38] Lottridge, 2022, Ally: Understanding Text Messaging to Build a Better Onscreen Keyboard for Blind People, ACM Trans. Access. Comput. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“These characteristics make it the most comprehensive academic search engine [28], removing the need to perform the search in each distinct reputable academic repository.”
What the sources say
- Supportedcites [28] Gusenbauer, 2019, Google Scholar to Overshadow Them All? Comparing the Sizes of 12 Academic Search Engines and Bibliographic Databases, Scientometrics source
The Abstract explicitly calls Google Scholar the most comprehensive academic search engine, estimating 389 million records. The Size section likewise says it provides by far the greatest volume of scholarly information among the systems examined. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“This dissonance makes the results in the reviewed literature difficult to contextualize and compare against related work in the field (e.g., as discussed in [103]).”
What the sources say
- Supportedcites [103] Meyer, 2021, An Analysis of Usability Evaluation Practices and Contexts of Use in Wearable Robotics, J. Neuroeng. Rehabil. source
The Usability evaluation practice section reports that more than half of surveyed wearable-robotics developers disagreed that they could compare their evaluation data with state-of-the-art benchmarks. The Usability measures and methods section explains that non-standardized metrics hinder the development of evaluation standards and benchmarks. These passages support the cited point that results are difficult to compare and contextualize; page numbers were not available in our copy. (LLM, conf=0.91)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Naturally, trying to fully comprehend the experience of a person with vision problems is hard, even with the use of advanced simulation techniques [95].”
What the sources say
- Supportedcites [95] Jones, 2020, Seeing Other Perspectives: Evaluating the Use of Virtual and Augmented Reality to Simulate Visual Impairments (OpenVisSim), npj Digit. Med. source
The Introduction explicitly says that even the most sophisticated simulator cannot recreate exactly what it is like to see through somebody else’s eyes. It also describes visual impairments as complex and variable, supporting the claim that fully comprehending another person’s experience remains difficult despite advanced simulation. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
67 more claims
Create a free account to see all 146 claims and every source verdict.
- It may state two separate claims as one. 49
- Probably not a substantial claim. 37
- The quote only partly states this claim. 4
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ 3.3.2. Participants
“We note that the average number of participants per study was almost twice as large in studies involving non-impaired persons ( ¯ c = 15.46, s = 5.04) compared with studies involving VIBPs ( ¯ c = 8.65, s = 3.4).”
§ 4.2. Evaluation Practice
“Starting with the participants, we found that studies with VIBPs involved, on average, a much lower count of participants ( ¯ c = 8.65) compared with the studies with non-impaired persons ( ¯ c = 16.15).”
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Tranfield, D., Denyer, D., & Smart, P. (2003) · British Journal of Management · doi:10.1111/1467-8551.00375 · Cited by 15,386
Literature review as a research methodology: An overview and guidelines
Snyder, H. (2019) · Journal of Business Research · doi:10.1016/j.jbusres.2019.07.039 · Cited by 11,524
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349
Flaxman, S. R., Bourne, R. R. A., Resnikoff, S., Ackland, P., Braithwaite, T., Cicinelli, M. V., Das, A., Jonas, J. B., Keeffe, J., Kempen, J. H., et al. (2017) · The Lancet Global Health · doi:10.1016/s2214-109x(17)30393-5 · Cited by 3,477
Guidance on Conducting a Systematic Literature Review
Xiao, Y., & Watson, M. (2019) · Journal of Planning Education and Research · doi:10.1177/0739456x17723971 · Cited by 3,467
Steinmetz, J. D., Bourne, R. R. A., Briant, P. S., Flaxman, S. R., Taylor, H. R. B., Jonas, J. B., Abdoli, A. A., Abrha, W. A., Abualhasan, A., Abu-Gharbieh, E. G., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30489-7 · Cited by 3,189
A Guide to Conducting a Standalone Systematic Literature Review
Okoli, C. (2015) · Communications of the Association for Information Systems · doi:10.17705/1cais.03743 · Cited by 1,413
Mengist, W., Soromessa, T., & Legese, G. (2020) · MethodsX · doi:10.1016/j.mex.2019.100777 · Cited by 1,110
Phrase sets for evaluating text entry techniques
MacKenzie, I. S., & Soukoreff, R. W. (2003) · CHI '03 extended abstracts on Human factors in computing systems - CHI '03 · doi:10.1145/765891.765971 · Cited by 825
Gusenbauer, M. (2019) · Scientometrics · doi:10.1007/s11192-018-2958-5 · Cited by 687
Local Standards for Sample Size at CHI
Caine, K. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858498 · Cited by 657
International Classification of Diseases 10th Revision (ICD-10)
DiSantostefano, J. (2009) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2008.09.020 · Cited by 651
Text Entry for Mobile Computing: Models and Methods, Theory and Practice
MacKenzie, I. S., & Soukoreff, R. W. (2002) · Human-Computer Interaction · doi:10.1207/s15327051hci172&3_2 · Cited by 571
Text Entry for Mobile Computing: Models and Methods,Theory and Practice
MacKenzie, I., & Soukoreff, R. W. (2002) · Hum. Comput. Interact. · doi:10.1080/07370024.2002.9667313 · Cited by 483
Systematic Literature Reviews: An Introduction
Lame, G. (2019) · Proceedings of the Design Society: International Conference on Engineering Design · doi:10.1017/dsi.2019.169 · Cited by 414
A guide to systematic literature reviews
Nightingale, A. (2009) · Surgery (Oxford) · doi:10.1016/j.mpsur.2009.07.005 · Cited by 413
Digital Literacy: A Review of Literature
Reddy, P., Sharma, B., & Chaudhary, K. (2020) · International Journal of Technoethics · doi:10.4018/ijt.20200701.oa1 · Cited by 398
Goldberg, D., & Richardson, C. (1993) · Proceedings of the SIGCHI conference on Human factors in computing systems - CHI '93 · doi:10.1145/169059.169093 · Cited by 322
Impact of unilateral and bilateral vision loss on quality of life
Vu, H. T. V. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.047498 · Cited by 302
Visual Impairment and Mental Health: Unmet Needs and Treatment Options
Demmin, D. L., & Silverstein, S. M. (2020) · Clinical Ophthalmology · doi:10.2147/opth.s258783 · Cited by 290
Methodology for systematic literature review applied to engineering and education
Torres-Carrion, P. V., Gonzalez-Gonzalez, C. S., Aciar, S., & Rodriguez-Morales, G. (2018) · 2018 IEEE Global Engineering Education Conference (EDUCON) · doi:10.1109/educon.2018.8363388 · Cited by 275
Brown, R. L., & Barrett, A. E. (2011) · The Journals of Gerontology Series B: Psychological Sciences and Social Sciences · doi:10.1093/geronb/gbr015 · Cited by 242
Phrase sets for evaluating text entry techniques
MacKenzie, I. S., & Soukoreff, R. W. (2003) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/765968.765971 · Cited by 211
Analysis of text entry performance metrics
Arif, A. S., & Stuerzlinger, W. (2009) · 2009 IEEE Toronto International Conference Science and Technology for Humanity (TIC-STH) · doi:10.1109/tic-sth.2009.5444533 · Cited by 206
Reyal, S., Zhai, S., & Kristensson, P. O. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702597 · Cited by 135
An evaluation of BrailleTouch: mobile touchscreen text entry for the visually impaired
Southern, C., Clawson, J., Frey, B., Abowd, G., & Romero, M. (2012) · Proceedings of the 14th international conference on Human-computer interaction with mobile devices and services · doi:10.1145/2371574.2371623 · Cited by 125
Elsman, E. B. M., Baaj, M. A., van Rens, G. H. M. B., Sijbrandi, W., van den Broek, E. G. C., van der Aa, H. P. A., Schakel, W., Heymans, M. W., de Vries, R., Vervloed, M. P. J., et al. (2019) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2019.01.010 · Cited by 121
Lee, H., Park, N., & Hwang, Y. (2015) · Telematics and Informatics · doi:10.1016/j.tele.2014.02.001 · Cited by 102
TipText: Eyes-Free Text Entry on a Fingertip Keyboard
Xu, Z.-E., Wong, P.-C., Gong, J., Wu, T.-Y., Nittala, A., Bi, X.-J., Steimle, J., Fu, H., Zhu, K.-N., & Yang, X.-D. (2019) · ACM Symposium on User Interface Software and Technology · doi:10.1145/3332165.3347865 · Cited by 100
Dunlop, M., & Levine, J. (2012) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2208659 · Cited by 99
Allmann, K., & Blank, G. (2021) · Information, Communication & Society · doi:10.1080/1369118x.2021.1874475 · Cited by 92
WrisText: One-handed Text Entry on Smartwatch using Wrist Gestures
Gong, J., Xu, Z., Guo, Q., Seyed, T., Chen, X. '., Bi, X., & Yang, X.-D. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173755 · Cited by 91
Zhang, M. R., Wen, H., & Wobbrock, J. O. (2019) · Proceedings of the 32nd Annual ACM Symposium on User Interface Software and Technology · doi:10.1145/3332165.3347924 · Cited by 86
Jones, P. R., Somoskeöy, T., Chow-Wing-Bom, H., & Crabb, D. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0242-6 · Cited by 79
Design patterns for mixed-method research in HCI
van Turnhout, K., Bennis, A., Craenmehr, S., Holwerda, R., Jacobs, M., Niels, R., Zaad, L., Hoppenbrouwers, S. J. B. A., Lenior, D., & Bakker, R. (2014) · Nordic Conference on Human-Computer Interaction · doi:10.1145/2639189.2639220 · Cited by 65
Recent developments in text-entry error rate measurement
Soukoreff, R. W., & MacKenzie, I. S. (2004) · CHI '04 Extended Abstracts on Human Factors in Computing Systems · doi:10.1145/985921.986081 · Cited by 65
FingerT9: Leveraging Thumb-to-finger Interaction for Same-side-hand Text Entry on Smartwatches
Wong, P. C., Zhu, K., & Fu, H. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173752 · Cited by 64
Complementing Text Entry Evaluations with a Composition Task
Vertanen, K., & Kristensson, P. O. (2014) · ACM Transactions on Computer-Human Interaction · doi:10.1145/2555691 · Cited by 62
TapType: Ten-finger text entry on everyday surfaces via Bayesian inference
Streli, P., Jiang, J., Fender, A. R., Meier, M., Romat, H., & Holz, C. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3501878 · Cited by 59
An Analysis of Usability Evaluation Practices and Contexts of Use in Wearable Robotics
Meyer, J. T., Gassert, R., & Lambercy, O. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00963-8 · Cited by 58
Artificial Intelligence for Human Computer Interaction: A Modern Approach
Huang, F., Schoop, E., Ha, D., Nichols, J. W., & Canny, J. (2021) · Human-computer interaction series · doi:10.1007/978-3-030-82681-9 · Cited by 44
The Impact of Word, Multiple Word, and Sentence Input on Virtual Keyboard Decoding Performance
Vertanen, K. D., Fletcher, C., Gaines, D. C., Gould, J., & Kristensson, P. O. (2018) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174200 · Cited by 43
Kumar, D., Hemmige, V., Kallen, M. A., Giordano, T. P., & Arya, M. (2019) · Cureus · doi:10.7759/cureus.4104 · Cited by 43
VelociWatch: Designing and Evaluating a Virtual Keyboard for the Input of Challenging Text
Vertanen, K., Gaines, D., Fletcher, C., Stanage, A. M., Watling, R., & Kristensson, P. O. (2019) · Proceedings of the 2019 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3290605.3300821 · Cited by 42
ForceBoard: Subtle Text Entry Leveraging Pressure
Zhong, M., Yu, C., Wang, Q., Xu, X., & Shi, Y. (2018) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174102 · Cited by 40
Human-Computer Interaction - INTERACT 2017
Bernhaupt, R., Dalvi, G., Joshi, A., Balkrishan, D. K., O’Neill, J., & Winckler, M. A. A. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67744-6 · Cited by 38
SingleTapBraille: Developing a Text Entry Method Based on Braille Patterns Using a Single Tap
Alnfiai, M. M., & Sampalli, S. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.08.038 · Cited by 36
BrailleSketch: A Gesture-based Text Input Method for People with Visual Impairments
Li, M., Fan, M., & Truong, K. N. (2017) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/3132525.3132528 · Cited by 35
The Limits of Expert Text Entry Speed on Mobile Keyboards with Autocorrect
Banovic, N., Sethapakdi, T., Hari, Y., Dey, A. K., & Mankoff, J. (2019) · Proceedings of the 21st International Conference on Human-Computer Interaction with Mobile Devices and Services · doi:10.1145/3338286.3340126 · Cited by 34
Analysis and Evaluation of Braille to Text Conversion Methods
Shokat, S., Riaz, R., Rizvi, S. S., Khan, K., Riaz, F., & Kwon, S. J. (2020) · Mobile Information Systems · doi:10.1155/2020/3461651 · Cited by 34
FingerText: Exploring and Optimizing Performance for Wearable, Mobile and One-Handed Typing
Lee, D., Kim, J., & Oakley, I. (2021) · Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445106 · Cited by 34
Alnfiai, M., & Sampalli, S. (2016) · Proceedings of the 18th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/2982142.2982161 · Cited by 33
Designing a text entry multimodal keypad for blind users of touchscreen mobile phones
Buzzi, M. C., Buzzi, M., Leporini, B., & Trujillo, A. (2014) · Proceedings of the 16th international ACM SIGACCESS conference on Computers & accessibility - ASSETS '14 · doi:10.1145/2661334.2661354 · Cited by 28
EdgeBraille: Braille-based text input for touch devices
Mattheiss, E. E., Regal, G., Schrammel, J., Garschall, M., & Tscheligi, M. (2015) · Journal of Assistive Technologies · doi:10.1108/jat-10-2014-0028 · Cited by 27
Word Clarity as a Metric in Sampling Keyboard Test Sets
Yi, X., Yu, C., Shi, W., Bi, X., & Shi, Y. (2017) · Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025701 · Cited by 26
JustCorrect: Intelligent Post Hoc Text Correction Techniques on Smartphones
Cui, W., Zhu, S., Zhang, M. R., Schwartz, H. A., Wobbrock, J. O., & Bi, X. (2020) · Proceedings of the 33rd Annual ACM Symposium on User Interface Software and Technology · doi:10.1145/3379337.3415857 · Cited by 24
Wyrich, M., Preikschat, A., Graziotin, D., & Wagner, S. (2021) · 2021 IEEE/ACM 43rd International Conference on Software Engineering (ICSE) · doi:10.1109/icse43902.2021.00055 · Cited by 24
BrailleEasy: One-handed Braille Keyboard for Smartphones
Barbara, Š., Ghanem, A., & Vogel, S. (2015) · Studies in health technology and informatics · doi:10.3233/978-1-61499-566-1-1030 · Cited by 21
Accessible Gesture Typing for Non-Visual Text Entry on Smartphones
Billah, S. M., Ko, Y.-J., Ashok, V., Bi, X., & Ramakrishnan, IV (2019) · Proceedings of the 2019 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3290605.3300606 · Cited by 21
Braille Text Entry on Smartphones: A Systematic Review of the Literature
Siqueira, J., Alves de Melo Soares, F. A., Ferreira, D. J., Silva, C. R. G., de Oliveira Berretta, L., Ferreira, C. B. R., Felix, I. M., da Silva Soares, A., Martins da Costa, R., & Luna, M. M. (2016) · 2016 IEEE 40th Annual Computer Software and Applications Conference (COMPSAC) · doi:10.1109/compsac.2016.74 · Cited by 20
Alnfiai, M., & Sampali, S. (2017) · 2017 International Conference on Computer and Applications (ICCA) · doi:10.1109/comapp.2017.8079740 · Cited by 20
BackSwipe: Back-of-device Word-Gesture Interaction on Smartphones
Cui, W., Zhu, S., Li, Z., Xu, Z., Yang, X.-D., Ramakrishnan, I. V., & Bi, X. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445081 · Cited by 20
Touchscreen Mobile Phones Virtual Keyboarding for People with Visual Disabilities
Façanha, A. R., Viana, W., Pequeno, M. C., Campos, M. D. B., & Sánchez, J. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07227-2_14 · Cited by 20
de Araújo, M. H., & Reinhard, N. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-27397-2_12 · Cited by 19
LightWrite: Teach Handwriting to The Visually Impaired with A Smartphone
Wu, Z., Yu, C., Xu, X., Wei, T., Zou, T., Wang, R., & Shi, Y. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445322 · Cited by 17
Mattheiss, E. E., Regal, G., Schrammel, J., Garschall, M., & Tscheligi, M. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-08596-8_100 · Cited by 17
Shi, W., Yu, C., Fan, S., Wang, F., Wang, T., Yi, X., Bi, X., & Shi, Y. (2019) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3290605.3300747 · Cited by 16
T18: an ambiguous keyboard layout for smartwatches
Rosa, M. D., Fuccella, V., Costagliola, G., Adinolfi, G., Ciampi, G., Corsuto, A., & Sapia, D. D. (2020) · IEEE International Conference on Human-Machine Systems (ICHMS) · doi:10.1109/ichms49158.2020.9209483 · Cited by 16
Leiva, L. A., & Sanchis-Trilles, G. (2014) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2556288.2557024 · Cited by 16
A Participatory Design and Formal Study Investigation into Mobile Text Entry for Older Adults
Nicol, E., Komninos, A., & Dunlop, M. D. (2016) · International Journal of Mobile Human Computer Interaction · doi:10.4018/ijmhci.2016040102.oa · Cited by 15
Self-citationMultilingual phrase sampling for text entry evaluations
Franco-Salvador, M., & Leiva, L. A. (2018) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2018.01.006 · Cited by 15
Senorita: A Chorded Keyboard for Sighted, Low Vision, and Blind Mobile Users
Rakhmetulla, G., & Arif, A. S. (2020) · Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376576 · Cited by 14
OneHandBraille: An Alternative Virtual Keyboard for Blind People
Dobosz, K., & Szuścik, M. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-67792-7_7 · Cited by 13
QB-Gest: Qwerty Bimanual Gestural Input for Eyes-Free Smartphone Text Input
Ye, L., Sandnes, F. E., & MacKenzie, I. S. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49282-3_16 · Cited by 13
Gaines, D., Kristensson, P. O., & Vertanen, K. (2021) · Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445199 · Cited by 13
(2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-72038-8 · Cited by 11
Lai (2019) · doi:10.1145/3343858 · Cited by 10
Computers Helping People with Special Needs
Miesenberger, K., Manduchi, R., RODRIGUEZ, M. C., et al. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-58805-2 · Cited by 9
Multi-touch gesture recognition of Braille input based on Petri Net and RBF Net
Zhang, J., & Zeng, X. (2021) · Multimedia Tools and Applications · doi:10.1007/s11042-021-11156-9 · Cited by 9
C-PAK: Correcting and Completing Variable-Length Prefix-Based Abbreviated Keystrokes
Li, T., Quinn, P., & Zhai, S. (2022) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3544101 · Cited by 9
Force9: Force-assisted Miniature Keyboard on Smart Wearables
Lee, L., Yeung, N. Y., Braud, T., Li, T., Su, X. J., & Hui, P. (2020) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/3382507.3418827 · Cited by 8
Performance of Accessible Gesture-Based Indic Keyboard
Bharath, P. A., Jadhav, C., Ahire, S., Joshi, M., Ahirwar, R., & Joshi, A. N. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67744-6_14 · Cited by 8
Text entry for the Blind on Smartwatches: A study of Braille code input methods for a novel device
Luna, M. M., Nascimento, H. A. D., Quigley, A., & Soares, F. (2023) · Universal Access in the Information Society · doi:10.1007/s10209-022-00870-2 · Cited by 7
Exploring an Ambiguous Technique for Eyes-Free Mobile Text Entry
Gaines, D. (2018) · Proceedings of the 20th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/3234695.3240991 · Cited by 6
Challenges in Mobile Text Entry using Virtual Keyboards for Low-Vision Users
Stefanis, V., Komninos, A., & Garofalakis, J. (2020) · 19th International Conference on Mobile and Ubiquitous Multimedia · doi:10.1145/3428361.3428391 · Cited by 6
Self-citationAlly: Understanding Text Messaging to Build a Better Onscreen Keyboard for Blind People
Lottridge, D., Yoon, C., Burton, D., Wang, C., & Kaye, J. (2022) · ACM Transactions on Accessible Computing · doi:10.1145/3533707 · Cited by 6
Optimizing User Interfaces for Human Performance
Oulasvirta, A. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-72038-8_1 · Cited by 6
Alhussaini, H., Ludi, S., & Leone, J. (2015) · Communications in Computer and Information Science · doi:10.1007/978-3-319-21383-5_62 · Cited by 5
Effects of Keyboard Background on Mobile Text Entry
Yadav, A., & Arif, A. S. (2018) · International Conference on Mobile and Ubiquitous Multimedia (MUM) · doi:10.1145/3282894.3282905 · Cited by 5
Braille text entry on smartwatches: an evaluation of methods for composing the Braille cell
Luna, M. M., de M. N. Soares, F. A. A., Nascimento, H. A. D., & Quigley, A. (2019) · Proceedings of the ACM SIGCHI Symposium on Engineering Interactive Computing Systems · doi:10.1145/3319499.3328233 · Cited by 5
A Review of Smartphone's Text Entry for Visually Impaired
Shahid, H., Ali Shah, M., Dar, B. K., & Fizzah, F. (2018) · 2018 24th International Conference on Automation and Computing (ICAC) · doi:10.23919/iconac.2018.8749128 · Cited by 5
Eyes-Free Text Entry with EdgeWrite Alphabets for Round-Face Smartwatches
Go, K., Kikawa, M., Kinoshita, Y., & Mao, X. (2019) · 2019 International Conference on Cyberworlds (CW) · doi:10.1109/cw.2019.00037 · Cited by 5
A One-Page Text Entry Method Optimized for Rectangle Smartwatches
Jang, R., Jung, C., Mohaisen, D., Lee, K., & Nyang, D. (2022) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2021.3057226 · Cited by 5
Phrase-Gesture Typing on Smartphones
Xu, Z., Meng, Y., Bi, X., & Yang, X.-D. (2022) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3526113.3545683 · Cited by 5
SwipeRing: Gesture Typing on Smartwatches Using a Segmented QWERTY Around the Bezel
Rakhmetulla, G., & Arif, A. (2021) · Junction Publishing · doi:10.20380/gi2021.19 · Cited by 5
An Empirical Evaluation of MoonTouch: A Soft Keyboard for Visually Impaired People
Heni, S., Abdallah, W., Archambault, D., Uzan, G., & Bouhlel, M. S. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41267-2_66 · Cited by 4
AI-Driven Intelligent Text Correction Techniques for Mobile Text Entry
Zhang, M. R., Wen, H., Cui, W., Zhu, S., Schwartz, H. A., Bi, X., & Wobbrock, J. O. (2021) · Human-computer interaction series · doi:10.1007/978-3-030-82681-9_5 · Cited by 4
(2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-27397-2 · Cited by 3
Samanta, D., & Chakraborty, T. S. (2020) · ACM Transactions on Accessible Computing · doi:10.1145/3406537 · Cited by 2
Efficient Typing on Ultrasmall Touch Screens With In Situ Decoder and Visual Feedback
Min, K.-B., & Seo, J. (2021) · IEEE Access · doi:10.1109/access.2021.3081173 · Cited by 2
Computational Design of Input Methods
Feit, A. M. (2017) · Proceedings of the 2017 CHI Conference Extended Abstracts on Human Factors in Computing Systems · doi:10.1145/3027063.3027134 · Cited by 1
Wyrich, M., Preikschat, A., Graziotin, D., & Wagner, S. (2020) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.4001763 · Cited by 1
DUCK: A DeDUCtive Soft Keyboard for Visually Impaired Users
Raynal, M., & Roussille, P. (2017) · Studies in health technology and informatics · doi:10.3233/978-1-61499-798-6-902 · Cited by 1
Systematic Literature Reviews: An Introduction
Lamé, G. (2019) · Apollo (University of Cambridge) · doi:10.17863/cam.38788
Increasing the Efficiency of Text Input in the 8pen Method
Dobosz, K., & Pindel, M. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-58805-2_42
An Analysis of Usability Evaluation Practices And Contexts of Use In Wearable Robotics
Meyer, J. T., Gassert, R., & Lambercy, O. (2021) · doi:10.21203/rs.3.rs-764275/v1
Research works printed but not linked: 6
- Komninos, A., and Simou, I. (2022, January 1). Text Entry Research-the Last 5 Years (2018–2022). Proceedings of the TEXT2030 Workshop Held at MobileHCI’22, Vancouver, BC, Canada.
- Mattheiss, E., Regal, G., Schrammel, J., Garschall, M., and Tscheligi, M. (2014). Computers Helping People with Special Needs: 14th International Conference, ICCHP 2014, Paris, France, July 9–11, 2014, Proceedings, Part I 14, Springer.
- Heni, S., Abdallah, W., Archambault, D., Archambault, D., Archambault, D., Uzan, G., and Bouhlel, M.S. (2016). Computers Helping People with Special Needs: 15th International Conference, ICCHP 2016, Linz, Austria, July 13–15, 2016, Proceedings, Part II 15, Springer.
- Raynal, M., and Roussille, P. (2017). Harnessing the Power of Technology to Improve Lives, IOS Press.
- Façanha, A.R., Viana, W., Pequeno, M.C., Campos, M.d.B., and Sánchez, J. (2014). Human-Computer Interaction. Applications and Services: 16th International Conference, HCI International 2014, Heraklion, Crete, Greece, June 22–27, 2014, Proceedings, Part III 16, Springer.
- MacKenzie, I.S., and Tanaka-Ishii, K. (2007). Text Entry Systems: Mobility, Accessibility, Universality, Morgan Kaufmann Publishers Inc.
Cited by
(2024) · doi:10.1145/3613904.3642939 · Cited by 31
A Haptic Braille Keyboard Layout for Smartphone Applications
Voutsakelis, G., Tzimos, N., Kokkonis, G., & Kontogiannis, S. I. (2024) · Electronics · doi:10.3390/electronics13122408 · Cited by 6
“Blind and visually impaired people can enter text via commercial or research-based applications [19].”
BackgroundAccessible Gesture Typing on Smartphones for People with Low Vision
Zhang, D., Li, Z., Ashok, V. G., Seiple, W., Ramakrishnan, I. V., & Bi, X. (2024) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3654777.3676447 · Cited by 8
RoboType: Realistic Mobile Text Entry Evaluations with Synthetic Users
Komninos, A. (2023) · International Conference on Human-Computer Interaction with Mobile Devices and Services (MobileHCI) · doi:10.1145/3565066.3608693 · Cited by 4
“This fact limits the number of participants in most mobile text entry experiments to an average of approximately 15 [14], with very few notable exceptions (e.g. [18]).”
BackgroundSelf-citationA Virtual Braille Keyboard Prototype for Accessible Text Input on Smartphones
Carvalho, L. B. D., Fonseca, A. U., Nascimento, T. H., Amorim, E., Felix, J., & Soares, F. A. A. D. M. N. (2026) · IEEE SoutheastCon · doi:10.1109/southeastcon63549.2026.11476388 · Cited by 2
“In [4], a systematic review analyzes and compares the methodologies adopted in these studies with those used in non-accessibility contexts, contributing to the establishment of best practices for the design and evaluation of text entry solutions for visually impaired users.”
Metadata
- Authors
- Komninos, A., Stefanis, V., & Garofalakis, J.
- Affiliations
- University of Patras (GR)
- Corresponding author
- Komninos, Andreas
- Venue
- Multimodal Technologies and Interaction
- Publisher
- MDPI AG
- Published
- 2023-02-17
- Volume
- 7
- Issue
- 2
- Pages
- 22
- ISSN
- 2414-4088 (ISSN-L)
- OpenAlex
- W4321374447
- Cited by
- 16
- References
- 94
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 7 · 2023: 1
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Multimodal Technologies and Interaction (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Greece and the European Union (European Social Fund (ESF)) (5047127)
- Topics
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Social Sciences › Human Factors and Ergonomics › Digital Accessibility for Disabilities
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Keywords
- mobile text entry, visually impaired users, blind users, visual impairment, accessibility, assistive technology, user interface design, usability evaluation, research methodology, reporting practices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.