The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index; 14 of the 35 sources its claims cite were checked for support.
Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links
Open accessAbstract
The International Association of Geodesy (IAG) aims to establish the International Height Reference System (IHRS) as one of its primary scientific objectives. Central to the realization of the IHRS is global vertical datum unification, which requires the connection of existing local vertical height reference systems (VHS) robustly and consistently. However, conventional methods are not suitable for estimating the offsets between two distant local height systems. In this paper, we propose a framework for connecting two local VHSs using ultraprecise clock frequency signal links between satellites and ground stations, referred to as the satellite frequency signal transmission (SFST) approach. The SFST approach allows for the direct determination of the geopotential and height differences between two ground datum stations without any location restrictions between the two VHSs. The simulation results show that the VHSs of China and the US can be unified with an accuracy of several centimeters, provided that the stability of atomic clocks used on-board the satellite and at on-ground datum locations reaches 4.8×10−17τ−1/2 for an averaging time τ (in seconds). We conclude that the SFST approach shows promise for achieving centimeter-level accuracy in unifying the global vertical height datum and represents a new paradigm for the realization of the IHRS.
Overview
CoChat Summary
TL;DR
The paper proposes a satellite frequency signal transmission (SFST) framework to connect distant local vertical height systems using ultraprecise clock frequency links, and tests it in simulation by unifying China’s and the US’ VHSs. It reports centimeter-level mean offsets but decimeter-level scatter over 1.5 h under assumed optical atomic clock stability of 4.8 × 10⁻¹⁷ at 1 s.
Key findings
- In the first simulation experiment connecting Qingdao Datum Station (QDDS, OH 72.260 m) and San Francisco Datum Station (SFDS, OH 109.126 m) via GPS satellite SVN-56 over 1.5 h (1080 observations at 5 s intervals), the mean offset was −3.6 cm and the STD was 12.1 cm.
- Across 10 simulation experiments, mean offsets were limited to the centimeter level, with the largest mean offset −7.5 cm in experiment 8; the average offset was 0.001 m and average STD 0.123 m, against an assumed true height difference of 1.000 m.
- The authors conclude that China’s and the US’ VHSs can be unified with several-centimeter accuracy if on-board and ground atomic clock stability reaches 4.8 × 10⁻¹⁷ τ⁻¹/², and that increasing the experiment period can improve accuracy.
Methods
- Simulation experiment comparing true values to simulated observations: two ground datum stations, QDDS and SFDS, were connected simultaneously to GPS satellite SVN-56, assumed equipped with two frequency signal transponders, from 6:00 a.m. to 7:30 a.m. on 1 March 2023 with 5 s sampling.
- True gravitational potentials were computed from EGM2008; satellite orbit came from IGS precise ephemeris interpolated to 5 s; ionosphere, troposphere, and tide corrections used the International Reference Ionosphere, Global Pressure and Temperature, and Tidal Potential models. Error sources included clock, ionosphere, troposphere, position/velocity, tide, and asynchronism, with clock error magnitude set to 4.8 × 10⁻¹⁷.
- Main analysis used SFST equations to determine the geopotential difference between QDDS and SFDS, converted it to a height difference, and compared the observed VHS difference to the assumed true 1.000 m; 10 simulations were run with randomly chosen error coefficients.
Limitations
- Stated: SFST requires frequency synchronization before measurement; initial synchronization error affects precision, and precisely synchronizing distant clocks is challenging, which the authors defer to a separate paper. It also requires ultrahigh-precision clocks and appropriate equipment, is slightly less precise than optical fiber link methods, and is best used as a supplement to conventional methods.
- Stated: only two stations were connected as a preliminary study; global unification would require a globally covered SFST network. Other time-varying gravity field changes such as atmospheric loading and ice loading were not considered because their residuals are at least one magnitude smaller than tidal residuals. Unknown δW_i means the height difference cannot be strictly determined, but this is neglected at the centimeter level because δW_i is usually less than 10 m²/s².
- Evident from the text: the results are from simulation, not real measurements; the GPS satellite was assumed to carry transponders not applicable to current GPS satellites; SFDS height was deduced from EGM2008 because the US has no corresponding height datum origin; and the true height difference was assumed to be 1.000 m.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
12 Valid · 5 Not valid · 15 Not checked · 39 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“However, with the fast development of high-precision clock manufacturing technology in recent years, optical atomic clocks (OACs), which have uncertainty and accuracy level of around 1 × 10 -18 and even higher have been developed in various laboratories [17][18][19][20].”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > 1. Introduction
What the sources say
- Supportedcites [17] McGrew, 2018, Atomic clock performance enabling geodesy below the centimetre level, Nature source
The paper reports two ytterbium optical lattice clocks with systematic uncertainty of 1.4 × 10⁻¹⁸ (p. 4). Its opening discussion also describes the performance of the current generation of optical clocks (p. 2), supporting the cited sentence’s broader background point. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [18] Huang, 2019, 40Ca+ ion optical clock with micromotion-induced shifts below 10−18, Phys. Rev. A source
- Supportedcites [19] Oelker, 2019, Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks, Nat. Photonics source
The introduction (p. 1) says optical clocks have surpassed microwave clocks in accuracy and precision. The references listed in the paper (Methods, p. 18) identify optical clocks with systematic uncertainties of 2 × 10⁻¹⁸ and 3 × 10⁻¹⁸, supporting the broad claim that clocks at around the 10⁻¹⁸ level have been developed. The paper's own sub-10⁻¹⁸ result is a precision measurement, not an accuracy measurement. (LLM, conf=0.85)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“though the residual influences of the ionosphere and troposphere for the SFST method are at the centimeter level (corresponding to a frequency shift at the 10 -18 level)”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > 4. Data Processing
What the sources say
- Supportedcites [34] Shen, 2017, Determination of Gravitational Potential at Ground Using Optical-Atomic Clocks on Board Satellites and on Ground Stations and Relevant Simulation Experiments, Surv. Geophys. source
Table 2 lists residual frequency errors of approximately 5.5 × 10^-19 for the ionosphere and 1.9 × 10^-19 for the troposphere after correction. Together they are of order 10^-18, consistent with a centimeter-level gravitational-potential measurement. The indexed copy does not provide a page number for the table. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Currently, precise OACs have achieved a stability of 4.8 × 10 -17 at 1 s and 6.6 × 10 -19 in 1 h for a two clock comparison [19]”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > 4. Data Processing
What the sources say
- Partly supportedcites [19] Oelker, 2019, Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks, Nat. Photonics sourceExperimental — accuracy not yet measured
The optical-clock intercomparison section (p. 7) derives a 4.8 × 10⁻¹⁷/√τ instability for each clock operating independently, which gives the cited value at 1 s. For the two-clock synchronous comparison, the paper reports a precision of 5.8(3) × 10⁻¹⁹ after one hour (p. 1), not 6.6 × 10⁻¹⁹; it also calls that one-hour result precision rather than stability. (LLM, conf=0.89)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Given the assumption that the stability of the OACs is 1 × 10 -18 within an hour, simulation experiments show that the precision of the geopotential difference between two stations on the ground can reach several centimeters in height [34].”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > 1. Introduction
What the sources say
- Supportedcites [34] Shen, 2017, Determination of Gravitational Potential at Ground Using Optical-Atomic Clocks on Board Satellites and on Ground Stations and Relevant Simulation Experiments, Surv. Geophys. source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Simulation experiments show that the precision of the geopotential difference between two ground sites determined by the SFST method is about 2∼5 cm in height [34], under the assumption that the accuracy of the OACs is about 1 × 10 -18 , which is achievable currently [17][18][19].”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > 2.2. SFST Method
What the sources say
- Supportedcites [34] Shen, 2017, Determination of Gravitational Potential at Ground Using Optical-Atomic Clocks on Board Satellites and on Ground Stations and Relevant Simulation Experiments, Surv. Geophys. source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
- Supportedcites [17] McGrew, 2018, Atomic clock performance enabling geodesy below the centimetre level, Nature source
This source is cited for the claim that optical atomic clocks can achieve accuracy of about 1 × 10⁻¹⁸, not for the SFST simulation’s 2–5 cm estimate, which the sentence cites separately. On p. 2, the paper reports a systematic uncertainty of 1.4 × 10⁻¹⁸ in its optical clocks and states that clock comparisons at the 1 × 10⁻¹⁸ level provide 1 cm resolution. (LLM, conf=0.91)
- Not checked — no full text of the sourcecites [18] Huang, 2019, 40Ca+ ion optical clock with micromotion-induced shifts below 10−18, Phys. Rev. A source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
28 more claims · 5 with their cited sources checked
Create a free account to see all 71 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 24
- Probably not a substantial claim. 19
- The quote only partly states this claim. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > Influential
“If δW China is unknown, the derived height of the SFDS ĤSF (t) cannot be calculated based on the height of the QDDS H QD , even though their geopotential difference is known.Therefore, the height difference between the two VHSs cannot be strictly determined.”
§ Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links > Influential
“H QD = W 0 + δW China -W QD ḡQD , H SF = W 0 + δW US -W SF ḡSF , ĤSF = W 0 + δW China -W QD -∆W QD-SF ḡSF , (20”
Citations
Cites
Gravitation and Cosmology: Principles and Applications of the General Theory of Relativity
Weinberg, S., & Dicke, R. H. (1973) · American Journal of Physics · doi:10.1119/1.1987308 · Cited by 3,103
The development and evaluation of the Earth Gravitational Model 2008 (EGM2008)
Pavlis, N. K., Holmes, S. A., Kenyon, S. C., & Factor, J. K. (2012) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2011jb008916 · Cited by 2,641
International Reference Ionosphere 2016: From ionospheric climate to real‐time weather predictions
Bilitza, D., Altadill, D., Truhlik, V., Shubin, V., Galkin, I., Reinisch, B., & Huang, X. (2017) · Space Weather · doi:10.1002/2016sw001593 · Cited by 1,046
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Short Note: A global model of pressure and temperature for geodetic applications
Boehm, J., Heinkelmann, R., & Schuh, H. (2007) · Journal of Geodesy · doi:10.1007/s00190-007-0135-3 · Cited by 717
Test of Relativistic Gravitation with a Space-Borne Hydrogen Maser
Vessot, R. F. C., Levine, M. W., Mattison, E. M., Blomberg, E. L., Hoffman, T. E., Nystrom, G. U., Farrel, B. F., Decher, R., Eby, P. B., Baugher, C. R., et al. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.2081 · Cited by 649
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Die Feldgleichungen der Gravitation
Einstein, A. (2005) · Albert Einstein: Akademie‐Vorträge · doi:10.1002/3527608958.ch5 · Cited by 370
Goals and status of the International Reference Ionosphere
Rawer, K., Bilitza, D., & Ramakrishnan, S. (1978) · Reviews of Geophysics · doi:10.1029/rg016i002p00177 · Cited by 275
Research works printed but not linked: 3
- Petit, 2010, IERS Conventions (2010), IERS Tech. Note, 36, 1
- Shen, 1993, On relativistic geoid, Boll. Geod. Sci. Affin., 52, 207
- Major, F.G. (2013). The Quantum Beat: The Physical Principles of Atomic Clocks, Springer Science & Business Media.
Cited by
Hoang, A. T., Shen, Z., & Shen, W. (2023) · IEEE Access · doi:10.1109/access.2023.3308519 · Cited by 7
Self-citationAdvances in time-frequency based geopotential determination
Sun, H., Shen, W., Gao, K., Gao, Y., Hou, M., Bao, L., Zhang, P., & Shen, Z. (2025) · Geodesy and Geodynamics · doi:10.1016/j.geog.2025.04.002 · Cited by 5
Self-citationUnifying the Nepal height system and China height system based on gravity frequency shift approach
Shanker, K. C., Shen, Z., & Shen, W. (2024) · Geodesy and Geodynamics · doi:10.1016/j.geog.2024.04.005 · Cited by 2
Self-citationAssessment of Measuring Orthometric Height With Multi-GNSS Undifferenced Time–Frequency Signals
Xu, W. S., Song, J., Zhang, P., & Zhao, L. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565063 · Cited by 1
“…navigation satellite system (GNSS), and determined the uncertainty of the height difference between the two stations to be about 4 cm. Shen et al. [31] carried out single geostationary orbit satellite microwave frequency signal transmission simulation experiments with a clock of 4.8 × 10 17 τ 1 2…”
InfluentialWu, K., Shen, W.-B., Fok, H. S., Lian, Z., Zhang, P., Li, L., Wang, L., Ning, A., Xu, R. L., & Shen, Z. (2025) · Advances in Space Research · doi:10.1016/j.asr.2025.10.010 · Cited by 4
Self-citation
Metadata
- Authors
- Shen, Z., Shen, W., Zhang, S., Shum, C. K., Zhang, T., He, L., Cai, Z., Xiong, S., & Wang, L.
- Affiliations
- Hubei University of Science and Technology (CN)
- Wuhan University (CN)
- The Ohio State University (US)
- Corresponding author
- Shen, Wenbin
- ORCID
- Venue
- Remote Sensing
- Publisher
- MDPI AG
- Published
- 2023-06-09
- Volume
- 15
- Issue
- 12
- Pages
- 3020
- ISSN
- 2072-4292 (ISSN-L)
- OpenAlex
- W4380080231
- Semantic Scholar
- 2c057581229a290761244b42d6587e772154ccf3
- Cited by
- 9
- References
- 55
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 1 · 2023: 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Remote Sensing (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (NSFC) (41721003, 42030105, 41631072, 41874023, 42274011, 41974034, 42204006, 2020-228)
- Space Station Project (41721003, 42030105, 41631072, 41874023, 42274011, 41974034, 42204006, 2020-228)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › GNSS positioning and interference
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Keywords
- International Height Reference System, vertical datum unification, geopotential difference, centimeter-level accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links. https://app.cochat.ai/papers/10.3390/rs15123020
- The paper
- Shen, Z., Shen, W., Zhang, S., Shum, C. K., Zhang, T., He, L., Cai, Z., Xiong, S., & Wang, L. (2023). Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links. Remote Sensing. https://doi.org/10.3390/rs15123020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.