Electrical Capacitance Volume Tomography: Design and Applications
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This article reports recent advances and progress in the field of electrical capacitance volume tomography (ECVT). ECVT, developed from the two-dimensional electrical capacitance tomography (ECT), is a promising non-intrusive imaging technology that can provide real-time three-dimensional images of the sensing domain. Images are reconstructed from capacitance measurements acquired by electrodes placed on the outside boundary of the testing vessel. In this article, a review of progress on capacitance sensor design and applications to multi-phase flows is presented. The sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of three-dimensional capacitance sensors are illustrated. The article also highlights applications of ECVT sensors on vessels of various sizes from 1 to 60 inches with complex geometries. Case studies are used to show the capability and validity of ECVT. The studies provide qualitative and quantitative real-time three-dimensional information of the measuring domain under study. Advantages of ECVT render it a favorable tool to be utilized for industrial applications and fundamental multi-phase flow research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development and validation of the State Hope Scale.
Snyder, C. R. R., Sympson, S. C., Ybasco, F. C., Borders, T. F., Babyak, M. A., & Higgins, R. L. (1996) · Journal of Personality and Social Psychology · doi:10.1037//0022-3514.70.2.321 · Cited by 3,520
Image reconstruction algorithms for electrical capacitance tomography
Yang, W., & Peng, L. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/14/1/201 · Cited by 1,150 · cited 3×
“Examples include Magnetic Resonance Imaging (MRI), Positron Emission Tomography (PET), X-ray tomography, γ-ray Tomography (GRT), Electrical Magnetic Tomography (EMT), and Electrical Capacitance Tomography (ECT) [19-40].”
BackgroundMethodFan, L., & Zhu, C. (1998) · Cambridge University Press eBooks · doi:10.1017/cbo9780511530142 · Cited by 656 · cited 1×
“Phases in such processes include gas-solid, gas-liquid, and gas-liquid-solid [1-6].”
BackgroundSelf-citationFluidization engineering, 2nd edition
Daizo, K., & Levenspiel, O. (1991) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 532
Gas–Liquid–Solid Fluidization Engineering
(1989) · Elsevier eBooks · doi:10.1016/c2009-0-24082-7 · Cited by 484 · cited 2×
“Straight vessels, such as fluidized bed reactors, solids pneumatic conveying systems, oil transport pipes, and liquid or gas storage tanks, are widely used in industry [6].”
BackgroundElectrical Capacitance Volume Tomography
Warsito, W., Marashdeh, Q., & Fan, L.-S. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.891952 · Cited by 245
Self-citationGranulation: A Review on Pharmaceutical Wet-Granulation
Kristensen, H. G., & Schaefer, T. (1987) · Drug Development and Industrial Pharmacy · doi:10.3109/03639048709105217 · Cited by 226
Taruno, W. P., & Fan, L.-S. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/12/323 · Cited by 142 · cited 3×
“In fluidized bed reactors, the gas/solid, gas/liquid/solid holdup, and bubble size distributions are obtained by ECT for basic multi-phase flow science, reactor design, and operation control [16,34,35,38-40,53-58].”
BackgroundMethodSelf-citationA nonlinear image reconstruction technique for ECT using a combined neural network approach
Marashdeh, Q. M., Taruno, W. P., Fan, L.-S., & Teixeira, F. L. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/8/007 · Cited by 133 · cited 1×
“In fluidized bed reactors, the gas/solid, gas/liquid/solid holdup, and bubble size distributions are obtained by ECT for basic multi-phase flow science, reactor design, and operation control [16,34,35,38-40,53-58].”
MethodSelf-citationTaruno, W. P., & Fan, L. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2005.01.033 · Cited by 112 · cited 4×
“The numerical method Sensors 2010, 10 1909 has been implemented based on the CFDLIB code, which was originally developed by Los Alamos National Laboratory, but has been extensively modified by Fan [74] to model various multi-phase problems.”
BackgroundMethodInfluentialSelf-citation
Cited by
Lower Limb Wearable Capacitive Sensing and Its Applications to Recognizing Human Gaits
Zheng, E., Chen, B., Wei, K., & Wang, Q. (2013) · Sensors · doi:10.3390/s131013334 · Cited by 26
Metadata
- Authors
- Wang, F., Marashdeh, Q., Fan, L.-S., & Warsito, W.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-03-09
- Volume
- 10
- Issue
- 3
- Pages
- 1890-1917
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2164413137
- Cited by
- 192
- References
- 16
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical Capacitance Volume Tomography: Design and Applications. https://app.cochat.ai/papers/10.3390/s100301890
- The paper
- Wang, F., Marashdeh, Q., Fan, L.-S., & Warsito, W. (2010). Electrical Capacitance Volume Tomography: Design and Applications. Sensors. https://doi.org/10.3390/s100301890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.