The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Metal Oxide Sensors for Electronic Noses and Their Application to Food Analysis
Open accessAbstract
Electronic noses (E-noses) use various types of electronic gas sensors that have partial specificity. This review focuses on commercial and experimental E-noses that use metal oxide semi-conductors. The review covers quality control applications to food and beverages, including determination of freshness and identification of contaminants or adulteration. Applications of E-noses to a wide range of foods and beverages are considered, including: meat, fish, grains, alcoholic drinks, non-alcoholic drinks, fruits, milk and dairy products, olive oils, nuts, fresh vegetables and eggs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Advanced Dairy Chemistry: Volume 3: Lactose, Water, Salts and Minor Constituents
(2009) · Springer eBooks · doi:10.1007/978-0-387-84865-5 · Cited by 1,094
The electronic nose applied to dairy products: a review
Ampuero, S., & Bosset, J. O. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00321-6 · Cited by 485
Semiconducting Metal Oxide Based Sensors for Selective Gas Pollutant Detection
Kanan, S. M., El-Kadri, O. M., Abu-Yousef, I. A., & Kanan, M. C. (2009) · Sensors · doi:10.3390/s91008158 · Cited by 447
‘Electronic Noses’ and Their Application to Food
Schaller, E., Bosset, J. O., & Escher, F. (1998) · LWT - Food Science and Technology · doi:10.1006/fstl.1998.0376 · Cited by 446
Olsson, J., Börjesson, T., Lundstedt, T., et al. (2002) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(01)00685-7 · Cited by 252
Electronic nose for monitoring the flavour of beers
Pearce, T. C., Gardner, J. W., Friel, S., Bartlett, P. N., & Blair, N. (1993) · The Analyst · doi:10.1039/an9931800371 · Cited by 220
Buratti, S., Benedetti, S., Scampicchio, M., & Pangerod, E. C. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.07.062 · Cited by 219
Application of an electronic nose to the discrimination of coffees
Gardner, J. W., Shurmer, H. V., & Tan, T. T. (1992) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(92)80033-t · Cited by 200
Tea quality prediction using a tin oxide-based electronic nose: an artificial intelligence approach
Dutta, R., Hines, E. L., Gardner, J. W., Kashwan, K. R., & Bhuyan, M. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00367-8 · Cited by 198
Cited by
Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, S.-W., & Tang, K.-T. (2013) · Sensors · doi:10.3390/s131014214 · Cited by 242
Ngoepe, M., Choonara, Y., Tyagi, C., Tomar, L., Du Toit, L., Kumar, P., Ndesendo, V., & Pillay, V. (2013) · Sensors · doi:10.3390/s130607680 · Cited by 92
Identification of Mint Scents Using a QCM Based E-Nose
Okur, S., Sarheed, M., Huber, R., Zhang, Z., Heinke, L., Kanbar, A., Wöll, C., Nick, P., & Lemmer, U. (2021) · Chemosensors · doi:10.3390/chemosensors9020031 · Cited by 44
Metadata
- Authors
- Berna, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-04-15
- Volume
- 10
- Issue
- 4
- Pages
- 3882-3910
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2100381264
- Cited by
- 339
- References
- 33
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal Oxide Sensors for Electronic Noses and Their Application to Food Analysis. https://app.cochat.ai/papers/10.3390/s100403882
- The paper
- Berna, A. (2010). Metal Oxide Sensors for Electronic Noses and Their Application to Food Analysis. Sensors. https://doi.org/10.3390/s100403882
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.