Cited by 187Carbon Nanotubes in CompositesAdvanced Sensor and Energy Harvesting MaterialsElectrical and Thermal Properties of Materials

Flexible Temperature Sensors on Fibers

Open access
Sibinski, Maciej, Jakubowska, Malgorzata, Sloma, Marcin·2010·Sensors

Abstract

The aim of this paper is to present research dedicated to the elaboration of novel, miniaturized flexible temperature sensors for textronic applications. Examined sensors were manufactured on a single yarn, which ensures their high flexibility and good compatibility with textiles. Stable and linear characteristics were obtained by special technological process and applied temperature profiles. As a thermo-sensitive materials the innovative polymer compositions filled with multiwalled carbon nanotubes were used. Elaborated material was adapted to printing and dip-coating techniques to produce NTC composites. Nanotube sensors were free from tensometric effect typical for other carbon-polymer sensor, and demonstrated TCR of 0.13%/K. Obtained temperature sensors, compatible with textile structure, can be applied in rapidly developing smart textiles and be used for health and protections purposes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s100907934

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Piezoresistive pressure sensors were knitted in a sock to wirelessly measure gate and plantar pressure up to 500 kPa.

    “In one such study, piezoresistive pressure sensors were knitted in a sock to wirelessly measure gate and plantar pressure up to 500 kPa.43”

    From Wearables in Medicine (2018) · cites this paper as [43]

    The Abstract and Conclusions identify this study as developing temperature sensors on single yarns to monitor skin temperature. They describe a different device from the claimed piezoresistive pressure-sensing sock; the paper does not report wireless gait or plantar-pressure measurements up to 500 kPa. (LLM, conf=0.85)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Electronic socks have also been developed to monitor vital functions in the body.

    “Electronic socks have also been developed to monitor vital functions in the body.”

    From Wearables in Medicine (2018) · cites this paper as [43]

    The “Flexible Sensors in Textile Applications” section says smart textiles use electronic sensors for bio-parameter monitoring, and the Conclusions report yarn-based temperature sensors that could be integrated into garments. Neither section says electronic socks have been developed, so the specific garment in the claim is unsupported. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • The data allowed evaluating running and walking modes of asymptomatic and flat foot.

    “The data allowed evaluating running and walking modes of asymptomatic and flat foot.”

    From Wearables in Medicine (2018) · cites this paper as [43]

    The paper’s Conclusions describe yarn-based sensors for measuring human skin temperature, not data evaluating running or walking in people with asymptomatic or flat feet. Searches for the claim’s wording and for flat-foot gait and plantar pressure found no passage addressing that comparison. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 10

  1. [1]Billinghurst M Starner T Wearable Devices: New Ways to Manage Information IEEE Comput 1999 32 57 64
  2. [2]Service RF Electronic Textiles Charge Ahead Science 2003 301 909 911 12920278
  3. [3]Park S Jayaraman S Enhancing the Quality of Life through Wearable Technology IEEE Eng. Med. Biol. Mag 2003 22 41 48 12845818
  4. [4]Paradiso R Gemignani A Scilingo EP De Rossi D Knitted Bioclothes for Cardiopulmonary Monitoring Proceeding of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Cancun, Mexico 17–21 September 2003
  5. [5]De Rossi D Lorussi F Mazzoldi A Orsini P Scilingo EP Active Dressware: Wearable Kinesthetic Systems in Sensors & Sensing Biology & Engineering Secomb J Springer Verlag New York, NJ, USA 2003 381 394
  6. [6]Shih WP Tsao LC Lee CW Cheng MY Chang CL Yang YJ Fan KC Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite Sensors 2010 10 3597 3610 PMC3274235 22319314
  7. [8]Lukasik A Nowak S Relaxation of Stress in Polymer-Carbon Microcomposite Resistive Layers Proceeding of Conference IMAPS-Poland Krakow, Poland 24–27 September 2006
  8. [13]Sirringhaus H Kawase T Friend RH Shimoda T Inbasekaran M Wu W Woo EP High-Resolution Inkjet Printing of All-Polymer Transistor Circuits Science 2000 290 2123 2126 11118142
  9. [14]Axisa F Dittmar A Delhomme G Smart Clothes for the Monitoring in Real Time and Conditions of Physiological, Emotional and Sensorial Reactions of Human Proceedings of the 25th Annual International Conference of the IEEE Cancun, Mexico 05 April 2004 3744 3747 17272152
  10. [19]Bielska S Ciupa E Raj E Sibinski M Comparison of Flexible Temperature Sensors Parameters, Based on Polymeric and Carbon Nanotubes Paste Proceeding of Microtherm 2009 Conference Lodz, Poland 28 June–1 July 2009 177 181

Cited by

Sorted by citations

Authors
Sibinski, M., Jakubowska, M., & Sloma, M.
Affiliations
  • Department of Semiconductor and Optoelectronics Devices, Technical University of Lodz/211/215 Wolczanska Street, 90-924 Lodz, Poland
  • Faculty of Mechatronicsm, Warsaw University of Technology/Sw. Andrzeja Boboli str. 8, 02-525 Warsaw, Poland
Venue
Sensors
Publisher
MDPI AG
Published
2010-08-26
Volume
10
Issue
9
Pages
7934-7946
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2029289155
Cited by
187
References
0
Citations by year
2026: 8 · 2025: 5 · 2024: 16 · 2023: 9 · 2022: 18 · 2021: 14 · 2020: 15 · 2019: 19 · 2018: 13 · 2017: 20 · 2016: 17 · 2015: 10 · 2014: 10 · 2013: 6 · 2012: 3
FWCI
2.04
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Carbon Nanotubes in Composites
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Thermal Properties of Materials
Keywords
flexible temperature sensors, smart textiles, multi-walled carbon nanotubes, NTC thermistor, carbon-polymer composites, dip coating, printing, temperature coefficient of resistance, health monitoring, protective clothing
MeSH terms
Temperature, Textile Industry, Thermometers, Nanotechnology, Nanotubes, Carbon, Electrical Equipment and Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review