The DOI matches its Crossref record.
Motion Mode Recognition and Step Detection Algorithms for Mobile Phone Users
Open accessAbstract
Microelectromechanical Systems (MEMS) technology is playing a key role in the design of the new generation of smartphones. Thanks to their reduced size, reduced power consumption, MEMS sensors can be embedded in above mobile devices for increasing their functionalities. However, MEMS cannot allow accurate autonomous location without external updates, e.g., from GPS signals, since their signals are degraded by various errors. When these sensors are fixed on the user’s foot, the stance phases of the foot can easily be determined and periodic Zero velocity UPdaTes (ZUPTs) are performed to bound the position error. When the sensor is in the hand, the situation becomes much more complex. First of all, the hand motion can be decoupled from the general motion of the user. Second, the characteristics of the inertial signals can differ depending on the carrying modes. Therefore, algorithms for characterizing the gait cycle of a pedestrian using a handheld device have been developed. A classifier able to detect motion modes typical for mobile phone users has been designed and implemented. According to the detected motion mode, adaptive step detection algorithms are applied. Success of the step detection process is found to be higher than 97% in all motion modes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wi-Fi Fingerprint-Based Indoor Positioning: Recent Advances and Comparisons
He, S., & Chan, S.-H. G. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2464084 · Cited by 1,355
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Fusion of Smartphone Motion Sensors for Physical Activity Recognition
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2014) · Sensors · doi:10.3390/s140610146 · Cited by 552
A Survey of Selected Indoor Positioning Methods for Smartphones
Davidson, P., & Piche, R. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2637663 · Cited by 515
Jahangiri, A., & Rakha, H. A. (2015) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2015.2405759 · Cited by 292
Lower Limb Wearable Capacitive Sensing and Its Applications to Recognizing Human Gaits
Zheng, E., Chen, B., Wei, K., & Wang, Q. (2013) · Sensors · doi:10.3390/s131013334 · Cited by 26
“Lower limb locomotion mode analysis is important in human gait monitoring [22,23], injury prevention and evaluation [24,25], as well as control of powered lower limb prostheses and exoskeletons [26–28].”
Background
Metadata
- Authors
- Susi, M., Renaudin, V., & Lachapelle, G.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-01-24
- Volume
- 13
- Issue
- 2
- Pages
- 1539-1562
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2025797281
- Cited by
- 231
- References
- 0
- FWCI
- 15.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.