The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
How can We Tackle Energy Efficiency in IoT BasedSmart Buildings?
Open accessAbstract
Nowadays, buildings are increasingly expected to meet higher and more complex performance requirements. Among these requirements, energy efficiency is recognized as an international goal to promote energy sustainability of the planet. Different approaches have been adopted to address this goal, the most recent relating consumption patterns with human occupancy. In this work, we analyze what are the main parameters that should be considered to be included in any building energy management. The goal of this analysis is to help designers to select the most relevant parameters to control the energy consumption of buildings according to their context, selecting them as input data of the management system. Following this approach, we select three reference smart buildings with different contexts, and where our automation platform for energy monitoring is deployed. We carry out some experiments in these buildings to demonstrate the influence of the parameters identified as relevant in the energy consumption of the buildings. Then, in two of these buildings are applied different control strategies to save electrical energy. We describe the experiments performed and analyze the results. The first stages of this evaluation have already resulted in energy savings of about 23% in a real scenario.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“As a starting point, we focus on the management of lights and HVAC subsystems since they have the highest energy consumption at building level [36].”
Background
Cited by
Jia, M., Komeily, A., Wang, Y., & Srinivasan, R. S. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.01.023 · Cited by 597
Green IoT: An Investigation on Energy Saving Practices for 2020 and Beyond
Arshad, R., Zahoor, S., Shah, M. A., Wahid, A., & Yu, H. (2017) · IEEE Access · doi:10.1109/access.2017.2686092 · Cited by 372
“City Explorer [52], a home automation solution, used in [53] to make strategies consists of 3 layers having data collection, data processing and services such as energy efficiency as their respective duties.”
MethodHaddud, A., DeSouza, A., Khare, A., & Lee, H. (2017) · Journal of Manufacturing Technology Management · doi:10.1108/jmtm-05-2017-0094 · Cited by 373
Metadata
- Authors
- Moreno, M., Úbeda, B., Skarmeta, A., & Zamora, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-05-30
- Volume
- 14
- Issue
- 6
- Pages
- 9582-9614
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2063151210
- Cited by
- 161
- References
- 1
- FWCI
- 16.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How can We Tackle Energy Efficiency in IoT BasedSmart Buildings? https://app.cochat.ai/papers/10.3390/s140609582
- The paper
- Moreno, M., Úbeda, B., Skarmeta, A., & Zamora, M. (2014). How can We Tackle Energy Efficiency in IoT BasedSmart Buildings? Sensors. https://doi.org/10.3390/s140609582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.