The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
An SVM-Based Solution for Fault Detection in Wind Turbines
Open accessAbstract
Research into fault diagnosis in machines with a wide range of variable loads and speeds, such as wind turbines, is of great industrial interest. Analysis of the power signals emitted by wind turbines for the diagnosis of mechanical faults in their mechanical transmission chain is insufficient. A successful diagnosis requires the inclusion of accelerometers to evaluate vibrations. This work presents a multi-sensory system for fault diagnosis in wind turbines, combined with a data-mining solution for the classification of the operational state of the turbine. The selected sensors are accelerometers, in which vibration signals are processed using angular resampling techniques and electrical, torque and speed measurements. Support vector machines (SVMs) are selected for the classification task, including two traditional and two promising new kernels. This multi-sensory system has been validated on a test-bed that simulates the real conditions of wind turbines with two fault typologies: misalignment and imbalance. Comparison of SVM performance with the results of artificial neural networks (ANNs) shows that linear kernel SVM outperforms other kernels and ANNs in terms of accuracy, training and tuning times. The suitability and superior performance of linear SVM is also experimentally analyzed, to conclude that this data acquisition technique generates linearly separable datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750
Cited by
Zhang, W., Peng, G., Li, C., Chen, Y., & Zhang, Z. (2017) · Sensors · doi:10.3390/s17020425 · Cited by 1,925
Machine learning methods for wind turbine condition monitoring: A review
Stetco, A., Dinmohammadi, F., Zhao, X., Robu, V., Flynn, D., Barnes, M., Keane, J., & Nenadic, G. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.047 · Cited by 831
Fault diagnosis of wind turbine based on Long Short-term memory networks
Lei, J., Liu, C., & Jiang, D. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.031 · Cited by 507
Damage detection techniques for wind turbine blades: A review
Du, Y., Zhou, S., Jing, X., Peng, Y., Wu, H., & Kwok, N. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106445 · Cited by 463
From Corrective to Predictive Maintenance—A Review of Maintenance Approaches for the Power Industry
Molęda, M., Małysiak-Mrozek, B., Ding, W., Sunderam, V., & Mrozek, D. (2023) · Sensors · doi:10.3390/s23135970 · Cited by 288
Metadata
- Authors
- Santos, P., Villa, L., Reñones, A., Bustillo, A., & Maudes, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-03-09
- Volume
- 15
- Issue
- 3
- Pages
- 5627-5648
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2030049536
- Cited by
- 223
- References
- 2
- FWCI
- 17.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An SVM-Based Solution for Fault Detection in Wind Turbines. https://app.cochat.ai/papers/10.3390/s150305627
- The paper
- Santos, P., Villa, L., Reñones, A., Bustillo, A., & Maudes, J. (2015). An SVM-Based Solution for Fault Detection in Wind Turbines. Sensors. https://doi.org/10.3390/s150305627
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.