The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A Vision-Based Sensor for Noncontact Structural Displacement Measurement
Open accessAbstract
Conventional displacement sensors have limitations in practical applications. This paper develops a vision sensor system for remote measurement of structural displacements. An advanced template matching algorithm, referred to as the upsampled cross correlation, is adopted and further developed into a software package for real-time displacement extraction from video images. By simply adjusting the upsampling factor, better subpixel resolution can be easily achieved to improve the measurement accuracy. The performance of the vision sensor is first evaluated through a laboratory shaking table test of a frame structure, in which the displacements at all the floors are measured by using one camera to track either high-contrast artificial targets or low-contrast natural targets on the structural surface such as bolts and nuts. Satisfactory agreements are observed between the displacements measured by the single camera and those measured by high-performance laser displacement sensors. Then field tests are carried out on a railway bridge and a pedestrian bridge, through which the accuracy of the vision sensor in both time and frequency domains is further confirmed in realistic field environments. Significant advantages of the noncontact vision sensor include its low cost, ease of operation, and flexibility to extract structural displacement at any point from a single measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Efficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905
Digital image correlation using Newton-Raphson method of partial differential correction
Bruck, H. A., McNeill, S. R., Sutton, M. A., & Peters, W. H. (1989) · Experimental Mechanics · doi:10.1007/bf02321405 · Cited by 1,456
Extension of phase correlation to subpixel registration
Foroosh, H., Zerubia, J. B., & Berthod, M. (2002) · IEEE Transactions on Image Processing · doi:10.1109/83.988953 · Cited by 978
Algorithms for subpixel registration
Tian, Q., & Huhns, M. N. (1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(86)90028-9 · Cited by 375
Debella-Gilo, M., & Kääb, A. (2010) · Remote Sensing of Environment · doi:10.1016/j.rse.2010.08.012 · Cited by 363
Ribeiro, D., Calçada, R., Ferreira, J., & Martins, T. (2014) · Engineering Structures · doi:10.1016/j.engstruct.2014.04.051 · Cited by 272
Vibration Monitoring of Multiple Bridge Points by Means of a Unique Vision-Based Measuring System
Busca, G., Cigada, A., Mazzoleni, P., & Zappa, E. (2013) · Experimental Mechanics · doi:10.1007/s11340-013-9784-8 · Cited by 218
Fukuda, Y., Feng, M. Q., Narita, Y., Kaneko, S., & Tanaka, T. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2273309 · Cited by 202
Self-citationVision-based monitoring system for evaluating cable tensile forces on a cable-stayed bridge
Kim, S., Jeon, B.-G., Kim, N.-S., & Park, J.-C. (2013) · Structural Health Monitoring · doi:10.1177/1475921713500513 · Cited by 173
Cost-effective vision-based system for monitoring dynamic response of civil engineering structures
Fukuda, Y., Feng, M. Q., & Shinozuka, M. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.360 · Cited by 172
Self-citationStatistics of subpixel registration algorithms based on spatiotemporal gradients or block matching
Davis, C. Q., & Freeman, D. M. (1998) · Optical Engineering · doi:10.1117/1.601966 · Cited by 153
Monitoring of a civil structure’s state based on noncontact measurements
Kohut, P., Holak, K., Uhl, T., Ortyl, Ł., Owerko, T., Kuraś, P., & Kocierz, R. (2013) · Structural Health Monitoring · doi:10.1177/1475921713487397 · Cited by 99
Vision-based algorithms for damage detection and localization in structural health monitoring
Dworakowski, Z., Kohut, P., Gallina, A., Holak, K., & Uhl, T. (2015) · Structural Control and Health Monitoring · doi:10.1002/stc.1755 · Cited by 97
Development of a vision based deflection measurement system and its accuracy assessment
Sładek, J. A., Ostrowska, K., Kohut, P., Holak, K., Gąska, A., & Uhl, T. (2012) · Measurement · doi:10.1016/j.measurement.2012.10.021 · Cited by 78
Virtual visual sensors and their application in structural health monitoring
Song, Y.-Z., Bowen, C., Kim, H. A., Nassehi, A., Padget, J. A., & Gathercole, N. (2014) · Structural Health Monitoring · doi:10.1177/1475921714522841 · Cited by 74
Schumacher, T., & Shariati, A. (2013) · Sensors · doi:10.3390/s131216551 · Cited by 68
Local positioning accuracy of laser sensors for structural health monitoring
Casciati, F., & Wu, L. (2012) · Structural Control and Health Monitoring · doi:10.1002/stc.1488 · Cited by 32
Cited by
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
A review of computer vision–based structural health monitoring at local and global levels
Dong, C.-Z., & Catbas, F. N. (2021) · Structural Health Monitoring · doi:10.1177/1475921720935585 · Cited by 795
Feng, D., & Feng, M. Q. (2018) · Engineering Structures · doi:10.1016/j.engstruct.2017.11.018 · Cited by 782
Self-citationA literature review of next-generation smart sensing technology in structural health monitoring
Sony, S., Laventure, S., & Sadhu, A. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2321 · Cited by 606
Deep learning-based structural health monitoring
Cha, Y.-J., Ali, R., Lewis, J., & Büyükӧztürk, O. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105328 · Cited by 418
Metadata
- Authors
- Feng, D., Feng, M., Ozer, E., & Fukuda, Y.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-07-09
- Volume
- 15
- Issue
- 7
- Pages
- 16557-16575
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1637731468
- Cited by
- 452
- References
- 18
- FWCI
- 37.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.