Designing a Microfluidic Device with Integrated Ratiometric Oxygen Sensors for the Long-Term Control and Monitoring of Chronic and Cyclic Hypoxia
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Control of oxygen over cell cultures in vitro is a topic of considerable interest, as chronic and cyclic hypoxia can alter cell behaviour. Both static and transient hypoxic levels have been found to affect tumour cell behaviour; it is potentially valuable to include these effects in early, in vitro stages of drug screening. A barrier to their inclusion is that rates of transient hypoxia can be a few cycles/hour, which is difficult to reproduce in traditional in vitro cell culture environments due to long diffusion distances from control gases to the cells. We use a gas-permeable three-layer microfluidic device to achieve spatial and temporal oxygen control with biologically-relevant switching times. We measure the oxygen profiles with integrated, ratiometric optical oxygen sensors, demonstrate sensor and system stability over multi-day experiments, and characterize a pre-bleaching process to improve sensor stability. We show, with both finite-element modelling and experimental data, excellent control over the oxygen levels by the device, independent of fluid flow rate and oxygenation for the operating flow regime. We measure equilibration times of approximately 10 min, generate complex, time-varying oxygen profiles, and study the effects of oxygenated media flow rates on the measured oxygen levels. This device could form a useful tool for future long-term studies of cell behaviour under hypoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bellot, G., Garcia-Medina, R., Gounon, P., Chiche, J., Roux, D., Pouysségur, J., & Mazure, N. M. (2009) · Molecular and Cellular Biology · doi:10.1128/mcb.00166-09 · Cited by 1,501
The hypoxic tumour microenvironment and metastatic progression
Subarsky, P., & Hill, R. P. (2003) · Clinical & Experimental Metastasis · doi:10.1023/a:1022939318102 · Cited by 327 · cited 1×
“While chronic or prolonged hypoxia has been found to act as a selective pressure for cells that are resistant to apoptosis [17,18], intermittent or cyclic hypoxia can also select for genotypes leading to tumour progression and resistance to therapy [19].”
BackgroundOxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188 · cited 1×
“summarizes the various methods that have been employed [32].”
Method
Cited by
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Koens, R., Tabata, Y., Serrano, J. C., Aratake, S., Yoshino, D., Kamm, R. D., & Funamoto, K. (2020) · APL Bioengineering · doi:10.1063/1.5127069 · Cited by 53
Berger Fridman, I., Ugolini, G. S., VanDelinder, V., Cohen, S., & Konry, T. (2021) · Biofabrication · doi:10.1088/1758-5090/abdb88 · Cited by 46
“Concentration gradient generators based on flow partition have been successfully coupled to bacterial or standard cell cultures [36, 37].”
Metadata
- Authors
- Grist, S., Schmok, J., Liu, M.-C., Chrostowski, L., & Cheung, K.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-08-14
- Volume
- 15
- Issue
- 8
- Pages
- 20030-20052
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2113099614
- Cited by
- 36
- References
- 3
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.