High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone
Open accessAbstract
In this paper, a smartphone-based lung function test, developed to estimate lung function parameters using a high-resolution time-frequency spectrum from a smartphone built-in microphone is presented. A method of estimation of the forced expiratory volume in 1 s divided by forced vital capacity (FEV1/FVC) based on the variable frequency complex demodulation method (VFCDM) is first proposed. We evaluated our proposed method on 26 subjects, including 13 healthy subjects and 13 chronic obstructive pulmonary disease (COPD) patients, by comparing with the parameters clinically obtained from pulmonary function tests (PFTs). For the healthy subjects, we found that an absolute error (AE) and a root mean squared error (RMSE) of the FEV1/FVC ratio were 4.49% ± 3.38% and 5.54%, respectively. For the COPD patients, we found that AE and RMSE from COPD patients were 10.30% ± 10.59% and 14.48%, respectively. For both groups, we compared the results using the continuous wavelet transform (CWT) and short-time Fourier transform (STFT), and found that VFCDM was superior to CWT and STFT. Further, to estimate other parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF), regression analysis was conducted to establish a linear transformation. However, the parameters FVC, FEV1, and PEF had correlation factor r values of 0.323, 0.275, and −0.257, respectively, while FEV1/FVC had an r value of 0.814. The results obtained suggest that only the FEV1/FVC ratio can be accurately estimated from a smartphone built-in microphone. The other parameters, including FVC, FEV1, and PEF, were subjective and dependent on the subject’s familiarization with the test and performance of forced exhalation toward the microphone.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Various sensors such as camera sensor, microphone sensor, accelerometer sensor, and gyroscope sensor were used in healthcare-based applications.
“Various sensors such as camera sensor [53–55], microphone sensor [56–58], accelerometer sensor [59–61], and gyroscope sensor [59, 62] were used in the healthcare-based applications.”
From Applications of Artificial Intelligence and Big Data Analytics in m-Health: A Healthcare System Perspective (2020) · cites this paper as [58]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cited by
Sorted by citations
khan, Z. F., & Alotaibi, S. R. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/8894694 · Cited by 235 · see citing works
- Authors
- Thap, T., Chung, H., Jeong, C., Hwang, K.-E., Kim, H.-R., Yoon, K.-H., & Lee, J.
- Affiliations
- Wonkwang University (KR)
- Department of Biomedical Engineering, Wonkwang University School of Medicine, 460 Iksandeaero, Iksan, Jeonbuk 570-749, Korea
- Imaging Science based Lung and Bone Disease Research Center, Wonkwang University, 460 Iksandeaero, Iksan, Jeonbuk 570-749, Korea
- Corresponding author
- Yoon, Kwon-Ha
- Lee, Jinseok
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-08-17
- Volume
- 16
- Issue
- 8
- Pages
- 1305
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC5017470
- OpenAlex
- W2517119194
- Cited by
- 34
- References
- 0
- Citations by year
- 2026: 2 · 2025: 5 · 2023: 4 · 2022: 7 · 2021: 4 · 2020: 5 · 2019: 4 · 2018: 2 · 2017: 1
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministry of Health and Welfare, Republic of Korea (HI12C0110)
- National Research Foundation of Korea (NRF) (NRF-2015M3A9D7067211, NRF-2013R1A1A1005775)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- smartphone microphone, time-frequency spectrum, FEV1/FVC ratio, forced vital capacity, forced expiratory volume, peak expiratory flow, chronic obstructive pulmonary disease, continuous wavelet transform, short-time Fourier transform, non-invasive respiratory monitoring
- MeSH terms
- Smartphone, Forced Expiratory Volume, Humans, Lung, Respiratory Function Tests, Spirometry, Tidal Volume, Vital Capacity, Pulmonary Disease, Chronic Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review