Utilizing a Wristband Sensor to Measure the Stress Level for People with Dementia
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Stress is a common problem that affects most people with dementia and their caregivers. Stress symptoms for people with dementia are often measured by answering a checklist of questions by the clinical staff who work closely with the person with the dementia. This process requires a lot of effort with continuous observation of the person with dementia over the long term. This article investigates the effectiveness of using a straightforward method, based on a single wristband sensor to classify events of “Stressed” and “Not stressed” for people with dementia. The presented system calculates the stress level as an integer value from zero to five, providing clinical information of behavioral patterns to the clinical staff. Thirty staff members participated in this experiment, together with six residents suffering from dementia, from two nursing homes. The residents were equipped with the wristband sensor during the day, and the staff were writing observation notes during the experiment to serve as ground truth. Experimental evaluation showed relationships between staff observations and sensor analysis, while stress level thresholds adjusted to each individual can serve different scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As for the assessment of personality profile and mood disturbances, there are groups that have monitored physiological signals such as heart rate variability and skin conductance to assess psychological function in different populations (116–118).”
From Could Wearable and Mobile Technology Improve the Management of Essential Tremor? (2018) · cites this paper as [118]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Global Measure of Perceived Stress
Cohen, S., Kamarck, T., & Mermelstein, R. (1983) · Journal of Health and Social Behavior · doi:10.2307/2136404 · Cited by 32,807
Hirono, N., Mori, E., Ikejiri, Y., Imamura, T., Shimomura, T., Hashimoto, M., Yamashita, H., & Ikeda, M. (1997) · Brain and nerve · Cited by 21,038
Kok, J. S., Berg, I. J., & Scherder, E. J. A. (2013) · Dementia and Geriatric Cognitive Disorders Extra · doi:10.1159/000353441 · Cited by 20,589
The Neuropsychiatric Inventory: Comprehensive assessment of psychopathology in dementia
Cummings, J. L., Mega, M., Gray, K., Rosenberg-Thompson, S., Carusi, D. A., & Gornbein, J. (1994) · Neurology · doi:10.1212/wnl.44.12.2308 · Cited by 7,568 · cited 1×
“The NPI-NH instrument, however, requires a lot of effort with continuous observation of the resident over long periods of time in order for the caregiver to get an understanding of the behavior [9].”
BackgroundSalivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532 · cited 1×
“[17] measured the cortisol in saliva to investigate the hypothalamus-pituitary-adrenal (HPA) axis activity.”
BackgroundEncyclopedia of Behavioral Medicine
(2013) · Springer eBooks · doi:10.1007/978-1-4419-1005-9 · Cited by 927
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742 · cited 1×
“Many studies suggested the use of physiological signals to detect stress and measure emotions of people, such as Skin Conductance [14], Blood Volume Pulse (BVP) [15] and Electroencephalography (EGG) [16].”
BackgroundAn inventory for the measurement of self‐reported stress and arousal
Mackay, C., Cox, T., Burrows, G., & Lazzerini, T. (1978) · British Journal of Social and Clinical Psychology · doi:10.1111/j.2044-8260.1978.tb00280.x · Cited by 533 · cited 2×
“Sensors 2016, 16, 1989 5 of 17 (Perala et al., 2007) Armband worn on the back of the upper arm: Galvanic Skin Response (GSR) Calculate the stress level based on GSR data Stress monitoring system (Hernandez et al., 2011) Wrist skin conductance sensor:Galvanic Skin Response (GSR) Calculate the stress level based on GSR…”
MethodChronic stress in elderly carers of dementia patients and antibody response to influenza vaccination
Vedhara, K., Cox, N. K., Wilcock, G. K., Perks, P., Hunt, M., Anderson, S., Lightman, S. L., & Shanks, N. M. (1999) · The Lancet · doi:10.1016/s0140-6736(98)06098-x · Cited by 496 · cited 3×
“[27] to investigate the effect of the stress on the immune system for people with dementia and their caregivers.”
BackgroundMethodA Stress Sensor Based on Galvanic Skin Response (GSR) Controlled by ZigBee
Villarejo, M. V., Zapirain, B. G., & Zorrilla, A. M. (2012) · Sensors · doi:10.3390/s120506075 · Cited by 315 · cited 1×
“[19] introduced a stress sensor based on Galvanic Skin Response (GSR), also known as skin conductance, and controlled by ZigBee.”
Background
Research works printed but not linked: 1
- Lupien, S.J. (2013). How to Measure Stress in Humans, Centre for Studies on Human Stress, Cambridge University Press. [2nd ed.].
Cited by
Electrodermal Activity Sensor for Classification of Calm/Distress Condition
Zangróniz, R., Martínez-Rodrigo, A., Pastor, J., López, M., & Fernández-Caballero, A. (2017) · Sensors · doi:10.3390/s17102324 · Cited by 186
Building pipelines for educational data using AI and multimodal analytics: A “grey‐box” approach
Sharma, K., Papamitsiou, Z., & Giannakos, M. (2019) · British Journal of Educational Technology · doi:10.1111/bjet.12854 · Cited by 130
“…the data sources (eg, number of fixations, blink presence, BVP) that have been commonly used in literature (D’Mello et al., 2018; Huang et al., 2007; Kikhia et al., 2016; Reichle et al., 2009), to add ground truth contextual knowledge (Di Mitri et al., 2018), that would be necessary for the…”
MethodLeng, M., Liu, P., Zhang, P., Hu, M., Zhou, H., Li, G., Yin, H., & Chen, L. (2019) · Psychiatry Research · doi:10.1016/j.psychres.2018.12.032 · Cited by 119
Delmastro, F., Martino, F. D., & Dolciotti, C. (2020) · IEEE Access · doi:10.1109/access.2020.2985301 · Cited by 112
“Reference [54] is the only study we found aimed at detecting stressful and non-stressful events in activity of daily living (ADL) of 6 older subjects with dementia, and it is based only on EDAmonitoring.”
BackgroundPortable System for Real-Time Detection of Stress Level
Minguillon, J., Perez, E., Lopez-Gordo, M. A., Pelayo, F., & Sanchez-Carrion, M. J. (2018) · Sensors · doi:10.3390/s18082504 · Cited by 97
“Examples include wearable assessment of mental stress of combatants [35], wristband sensor to measure stress level for people with dementia [36], and stress detection in drivers [37–39].”
Background
Metadata
- Authors
- Kikhia, B., Stavropoulos, T., Andreadis, S., Karvonen, N., Kompatsiaris, I., Sävenstedt, S., Pijl, M., & Melander, C.
- Affiliations
- Luleå University of Technology (SE)
- Information Technologies Institute (GR)
- Philips (Netherlands) (NL)
- Corresponding author
- Kikhia, Basel
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-11-24
- Volume
- 16
- Issue
- 12
- Pages
- 1989
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC5190970
- OpenAlex
- W2557195412
- Cited by
- 89
- References
- 31
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 9 · 2023: 10 · 2022: 8 · 2021: 14 · 2020: 14 · 2019: 9 · 2018: 11 · 2017: 3
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Health Sciences › Medicine › Psychiatry and Mental health › Dementia and Cognitive Impairment Research
- Keywords
- dementia, stress measurement, wrist-worn sensors, wearable sensors, stress classification, behavioral patterns, nursing homes, caregiver observation
- MeSH terms
- Wearable Electronic Devices, Dementia, Humans, Monitoring, Physiologic, Nursing Homes, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Utilizing a Wristband Sensor to Measure the Stress Level for People with Dementia. https://app.cochat.ai/papers/10.3390/s16121989
- The paper
- Kikhia, B., Stavropoulos, T., Andreadis, S., Karvonen, N., Kompatsiaris, I., Sävenstedt, S., Pijl, M., & Melander, C. (2016). Utilizing a Wristband Sensor to Measure the Stress Level for People with Dementia. Sensors. https://doi.org/10.3390/s16121989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.