Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2006) · Wiley eBooks · doi:10.1002/9780470612071 · Cited by 462
Li, S., Laima, S., & Li, H. (2017) · Engineering Structures · doi:10.1016/j.engstruct.2017.02.024 · Cited by 96 · cited 6×
“The processor board, a customized Mini4357 developed by Embest Technology (Shenzhen, China), features an LPC4357 microprocessor from NXP (Eindhoven, The Netherlands) that operates with a dual Cortex M4/M0 core (ARM, Cambridge, UK) at frequencies up to 204 MHz.”
BackgroundInfluential
Cited by
Abdulkarem, M., Samsudin, K., Rokhani, F. Z., & A Rasid, M. F. (2020) · Structural Health Monitoring · doi:10.1177/1475921719854528 · Cited by 424
Tibaduiza Burgos, D. A., Gomez Vargas, R. C., Pedraza, C., Agis, D., & Pozo, F. (2020) · Sensors · doi:10.3390/s20030733 · Cited by 174
“It is also possible to take advantage of other attractive features [125], such as their small size [126] or their ability to easily connect to a wireless sensor network [127].”
BackgroundMethodInfluentialKeshmiry, A., Hassani, S., Mousavi, M., & Dackermann, U. (2023) · Buildings · doi:10.3390/buildings13040918 · Cited by 117
Structural Health Monitoring Damage Detection Systems for Aerospace
(2021) · Springer Aerospace Technology · doi:10.1007/978-3-030-72192-3 · Cited by 92
Wondra, B., Malek, S., Botz, M., Glaser, S. D., & Grosse, C. U. (2019) · Data-Enabled Discovery and Applications · doi:10.1007/s41688-018-0029-y · Cited by 28
Metadata
- Authors
- Zhu, L., Fu, Y., Chow, R., Spencer, B., Park, J., & Mechitov, K.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-01-17
- Volume
- 18
- Issue
- 1
- Pages
- 262
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2793434078
- Cited by
- 119
- References
- 2
- FWCI
- 11.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.