Hydrogel-Based Fluorescent Dual pH and Oxygen Sensors Loaded in 96-Well Plates for High-Throughput Cell Metabolism Studies
The DOI matches its Crossref record.
Abstract
In this study, we developed fluorescent dual pH and oxygen sensors loaded in multi-well plates for in-situ and high-throughput monitoring of oxygen respiration and extracellular acidification during microbial cell growth for understanding metabolism. Biocompatible PHEMA-co-PAM materials were used as the hydrogel matrix. A polymerizable oxygen probe (OS2) derived from PtTFPP and a polymerizable pH probe (S2) derived from fluorescein were chemically conjugated into the matrix to solve the problem of the probe leaching from the matrix. Gels were allowed to cure directly on the bottom of 96-well plates at room-temperature via redox polymerization. The influence of matrix’s composition on the sensing behaviors was investigated to optimize hydrogels with enough robustness for repeatable use with good sensitivity. Responses of the dual sensing hydrogels to dissolved oxygen (DO) and pH were studied. These dual oxygen-pH sensing plates were successfully used for microbial cell-based screening assays, which are based on the measurement of fluorescence intensity changes induced by cellular oxygen consumption and pH changes during microbial growth. This method may provide a real-time monitoring of cellular respiration, acidification, and a rapid kinetic assessment of multiple samples for cell viability as well as high-throughput drug screening. All of these assays can be carried out by a conventional plate reader.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because of the influence of bioactive chitosan and trimethyl chitosan, cellular oxygen consumption in a microaerophilic environment [68] can be correlated to microbial growth inhibition via cell lysis [74].”
From Antimicrobial Efficiency of Chitosan and Its Methylated Derivative against Lentilactobacillus parabuchneri Biofilms (2022) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 36
- Beal, 1993, Do defecs in mitochondrial energy metabolism underlie the pathology of neurodegenerative diseases?, Trends Neurosci., 16, 125, 10.1016/0166-2236(93)90117-5 · DOI · Paper page
- Rosas, 1999, The effect of dissolved oxygen and salinity on oxygen consumption, ammonia excretion and osmotic pressure of Penaeus setiferus (Linnaeus) juveniles, J. Exp. Mar. Biol. Ecol., 234, 41, 10.1016/S0022-0981(98)00139-7 · DOI
- Morrison, 2000, Culture in reduced levels of oxygen promotes clonogenic sympathoadrenal differentiation by isolated neural crest stem cells, J. Neurosci., 20, 7370, 10.1523/JNEUROSCI.20-19-07370.2000 · DOI · Paper page
- Amon, 1996, Photochemical and microbial consumption of dissolved organic carbon and dissolved oxygen in the Amazon River system, Geochim. Cosmochim. Acta, 60, 1783, 10.1016/0016-7037(96)00055-5 · DOI · Paper page
- Bandyopadhyay, 1999, Reactive oxygen species: Oxidative damage and pathogenesis, Curr. Sci., 77, 658
- Apel, 2004, Reactive oxygen species: Metabolism, oxidative stress, and signal transduction, Annu. Rev. Plant Biol., 55, 373, 10.1146/annurev.arplant.55.031903.141701 · DOI · Paper page
- Su, 2011, Catechol polymers for pH-responsive, targeted drug delivery to cancer cells, J. Am. Chem. Soc., 133, 11850, 10.1021/ja203077x · DOI · Paper page
- Hansen, 2016, Influence of extracellular pH on growth, viability, cell size, acidification activity, and intracellular pH of lactococcus lactis in batch fermentations, Appl. Microbiol. Biotechnol., 100, 5965, 10.1007/s00253-016-7454-3 · DOI
- Hainaut, 2013, Targeting the hallmarks of cancer: Towards a rational approach to next-generation cancer therapy, Curr. Opin. Oncol., 25, 50, 10.1097/CCO.0b013e32835b651e · DOI · Paper page
- Hanahan, 2011, Hallmarks of cancer: The next generation, Cell, 144, 646, 10.1016/j.cell.2011.02.013 · DOI · Paper page
- Wang, 2014, Optical methods for sensing and imaging oxygen: Materials, spectroscopies and applications, Chem. Soc. Rev., 43, 3666, 10.1039/C4CS00039K · DOI · Paper page
- Wolfbeis, 2005, Materials for fluorescence-based optical chemical sensors, J. Mater. Chem., 15, 2657, 10.1039/b501536g · DOI · Paper page
- Wolfbeis, 2000, Fiber-optic chemical sensors and biosensors, Anal. Chem., 72, 81, 10.1021/a1000013k · DOI · Paper page
- Zou, 2017, Luminescence materials for pH and oxygen sensing in microbial cells-structures, optical properties, and biological applications, Crit. Rev. Biotechnol., 37, 723, 10.1080/07388551.2016.1223011 · DOI
- Nagl, 2007, Optical multiple chemical sensing: Status and current challenges, Analyst, 132, 507, 10.1039/b702753b · doi:10.1039/b702753b
- Vasylevska, 2006, Indicator-loaded permeation-selective microbeads for use in fiber optic simultaneous sensing of pH and dissolved oxygen, Chem. Mater., 18, 4609, 10.1021/cm060967n · DOI
- Polerecky, 2007, Time-resolved pH/pO2 mapping with luminescent hybrid sensors, Anal. Chem., 79, 60, 10.1021/ac0606047 · DOI
- Nagl, 2008, Multiplex bacterial growth monitoring in 24-well microplates using a dual optical sensor for dissolved oxygen and pH, Biotechnol. Bioeng., 100, 430, 10.1002/bit.21793 · DOI
- Lu, 2011, New ratiometric optical oxygen and pH dual sensors with three emission colors for measuring photosynthetic activity in cyanobacteria, J. Mater. Chem., 21, 19293, 10.1039/c1jm13754a · DOI
- Wang, 2012, Ultra-small, highly stable, and sensitive dual nanosensors for imaging intracellular oxygen and pH in cytosol, J. Am. Chem. Soc., 134, 17011, 10.1021/ja308830e · DOI · Paper page
- Meier, 2011, Simultaneous photographing of oxygen and pH in vivo using sensor films, Angew. Chem. Int. Ed., 50, 10893, 10.1002/anie.201104530 · DOI
- Zhou, X.F., Su, F.Y., Tian, Y.Q., and Meldrum, D.R. (2014). Dually fluorescent core-shell microgels for ratiometric imaging in live antigen-presenting cells. PLoS ONE, 9. · DOI
- Borchert, 2011, O2/pH multisensor based on one phosphorescent dye, Anal. Chem., 83, 18, 10.1021/ac1025754 · doi:10.1021/ac1025754
- Wang, 2013, Fluorescent pH-sensitive nanoparticles in an agarose matrix for imaging of bacterial growth and metabolism, Angew. Chem. Int. Ed., 52, 406, 10.1002/anie.201205715 · DOI
- Birmele, 2006, Characterization of methods for determining sterilization efficacy and reuse efficiency of oxygen biosensor multiwell plates, J. Microbiol. Meth., 67, 619, 10.1016/j.mimet.2006.06.003 · doi:10.1016/j.mimet.2006.06.003
- Chen, 2002, Characterization of ormosil film for dissolved oxygen-sensing, Sens. Actuators B Chem., 87, 233, 10.1016/S0925-4005(02)00241-1 · DOI
- Strobl, 2016, Design and application of an optical sensor for simultaneous imaging of pH and dissolved O2 with low cross-talk, ACS Sens., 1, 681, 10.1021/acssensors.6b00071 · doi:10.1021/acssensors.6b00071
- Tian, 2010, A series of naphthalimide derivatives as intra and extracellular pH sensors, Biomaterials, 31, 7411, 10.1016/j.biomaterials.2010.06.023 · DOI
- Tian, 2010, Influence of matrices on oxygen sensing of three sensing films with chemically conjugated platinum porphyrin probes and preliminary application for monitoring of oxygen consumption of Escherichia coli (E. coli), Sens. Actuators B Chem., 150, 579, 10.1016/j.snb.2010.08.036 · DOI · Paper page
- Tian, 2010, A new cross-linkable oxygen sensor covalently bonded into poly(2-hydroxyethyl methacrylate)-co-polyacrylamide thin film for dissolved oxygen sensing, Chem. Mater., 22, 2069, 10.1021/cm903361y · doi:10.1021/cm903361y
- Tian, 2010, Dually fluorescent sensing of pH and dissolved oxygen using a membrane made from polymerizable sensing monomers, Sens. Actuators B Chem., 147, 714, 10.1016/j.snb.2010.03.029 · doi:10.1016/j.snb.2010.03.029
- Sarac, 1999, Redox polymerization, Prog. Polym. Sci., 24, 1149, 10.1016/S0079-6700(99)00026-X · DOI · Paper page
- Fornasiero, 2005, Steady-state diffusion of water through soft-contact-lens materials, Biomaterials, 26, 5704, 10.1016/j.biomaterials.2005.02.028 · doi:10.1016/j.biomaterials.2005.02.028
- Wang, 2008, Influence of water states in hydrogels on the transmissibility and permeability of oxygen in contact lens materials, Appl. Surf. Sci., 255, 604, 10.1016/j.apsusc.2008.06.178 · DOI
- Buckley, 2000, A cell viability assay based on monitoring respiration by optical oxygen sensing, Anal. Biochem., 278, 221, 10.1006/abio.1999.4431 · DOI
- West, 1974, Proton/sodium ion antiport in Escherichia coli, Biochem. J., 144, 87, 10.1042/bj1440087 · DOI · Paper page
Cited by
Hydrogel-Based Sensor Networks: Compositions, Properties, and Applications—A Review
Sun, X., Agate, S., Salem, K. S., Lucia, L., & Pal, L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01011 · Cited by 279
Bajrami, D., Fischer, S., Barth, H., Hossain, S. I., Cioffi, N., & Mizaikoff, B. (2022) · Molecules · doi:10.3390/molecules27248647 · Cited by 20
Cost-Effective Real-Time Metabolic Profiling of Cancer Cell Lines for Plate-Based Assays
Blaszczak, W., Tan, Z., & Swietach, P. (2021) · Chemosensors · doi:10.3390/chemosensors9060139 · Cited by 10
Metadata
- Authors
- Wu, S., Wu, S., Yi, Z., Zeng, F., Wu, W., Qiao, Y., Zhao, X., Cheng, X., & Tian, Y.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-02-13
- Volume
- 18
- Issue
- 2
- Pages
- 564
- ISSN
- 1424-8220
- Cited by
- 41
- References
- 0
- Language
- en
- Funders
- National Science Foundation of China (21574061 and 21604036)
- Shenzhen fundamental research programs (JCYJ20150630145302243)
- start fund of SUSTech (FRG-SUSTC1501A-01, Y01256009)
- Shenzhen Science and Technology Innovation Committee for key laboratory (ZDSYS20140509142721431)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.