The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Non-Specific Adsorption Reduction Methods in Biosensing
Open accessAbstract
Non-specific adsorption (NSA) is a persistent problem that negatively affects biosensors, decreasing sensitivity, specificity, and reproducibility. Passive and active removal methods exist to remedy this issue, by coating the surface or generating surface forces to shear away weakly adhered biomolecules, respectively. However, many surface coatings are not compatible or effective for sensing, and thus active removal methods have been developed to combat this phenomenon. This review aims to provide an overview of methods of NSA reduction in biosensing, focusing on the shift from passive methods to active methods in the past decade. Attention is focused on protein NSA, due to their common use in biosensing for biomarker diagnostics. To our knowledge, this is the first review to comprehensively discuss active NSA removal methods. Lastly, the challenges and future perspectives of NSA reduction in biosensing are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Gref, R., Lück, M., Quellec, P., Marchand, M., Dellacherie, E., Harnisch, S., Blunk, T., & Müller, R. H. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00156-3 · Cited by 1,723
Prime, K. L., & Whitesides, G. M. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00076a032 · Cited by 1,620
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
A Review of Cell Adhesion Studies for Biomedical and Biological Applications
Khalili, A., & Ahmad, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160818149 · Cited by 951
Zwitteration: Coating Surfaces with Zwitterionic Functionality to Reduce Nonspecific Adsorption
Schlenoff, J. B. (2014) · Langmuir · doi:10.1021/la500057j · Cited by 951
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Ladd, J., Zhang, Z., Chen, S., Hower, J. C., & Jiang, S. (2008) · Biomacromolecules · doi:10.1021/bm701301s · Cited by 808
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Template-imprinted nanostructured surfaces for protein recognition
Shi, H., Tsai, W.-B., Garrison, M. D., Ferrari, S., & Ratner, B. D. (1999) · Nature · doi:10.1038/19267 · Cited by 684
Cited by
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Guselnikova, O., Lim, H., Kim, H., Kim, S. H., Gorbunova, A., Eguchi, M., Postnikov, P., Nakanishi, T., Asahi, T., Na, J., et al. (2022) · Small · doi:10.1002/smll.202107182 · Cited by 263
Self-citationSon, N., & Hong, S. (2025) · Materials Today · doi:10.1016/j.mattod.2025.06.021 · Cited by 9
Metadata
- Authors
- Lichtenberg, J. Y., Ling, Y., & Kim, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-05-31
- Volume
- 19
- Issue
- 11
- Pages
- 2488
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2946856772
- Cited by
- 296
- References
- 60
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-Specific Adsorption Reduction Methods in Biosensing. https://app.cochat.ai/papers/10.3390/s19112488
- The paper
- Lichtenberg, J. Y., Ling, Y., & Kim, S. (2019). Non-Specific Adsorption Reduction Methods in Biosensing. Sensors. https://doi.org/10.3390/s19112488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.