CoChat

Medical-Grade ECG Sensor for Long-Term Monitoring

Rashkovska, Aleksandra, Depolli, Matjaž, Tomašić, Ivan, Avbelj, Viktor, Trobec, Roman · 2020 · Sensors
Cited by 65

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The recent trend in electrocardiogram (ECG) device development is towards wireless body sensors applied for patient monitoring. The ultimate goal is to develop a multi-functional body sensor that will provide synchronized vital bio-signs of the monitored user. In this paper, we present an ECG sensor for long-term monitoring, which measures the surface potential difference between proximal electrodes near the heart, called differential ECG lead or differential lead, in short. The sensor has been certified as a class IIa medical device and is available on the market under the trademark Savvy ECG. An improvement from the user’s perspective—immediate access to the measured data—is also implemented into the design. With appropriate placement of the device on the chest, a very clear distinction of all electrocardiographic waves can be achieved, allowing for ECG recording of high quality, sufficient for medical analysis. Experimental results that elucidate the measurements from a differential lead regarding sensors’ position, the impact of artifacts, and potential diagnostic value, are shown. We demonstrate the sensors’ potential by presenting results from its various areas of application: medicine, sports, veterinary, and some new fields of investigation, like hearth rate variability biofeedback assessment and biometric authentication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20061695

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 30

  1. Einthoven, 1913, Über die Richtung und die manifeste Grösse der Potentialschwankungen im menschlichen Herzen und über den Einfluss der Herzlage auf die Form des Elektrokardiogramms, Pflüger’s Archiv für die gesamte Physiologie des Menschen und der Tiere, 150, 275, 10.1007/BF01697566 · DOI · Paper page
  2. Macfarlane, P.W., and Lawrie, T.D.V. (1989). Comprehensive Electrocardiology, Theory and Practice in Health and Disease, Pergamon Press.
  3. Trobec, 2003, Computer analysis of multichannel ECG, Comput. Biol. Med., 33, 215, 10.1016/S0010-4825(02)00088-4 · doi:10.1016/s0010-4825(02)00088-4
  4. Zellerhoff, 2000, How can we identify the best implantation site for an ECG event recorder?, Pacing Clin. Electrophysiol., 23, 1545, 10.1046/j.1460-9592.2000.01545.x · doi:10.1046/j.1460-9592.2000.01545.x
  5. Bifulco, P., Cesarelli, M., Fratini, A., Ruffo, M., Pasquariello, G., and Gargiulo, G. (2011, January 30–31). A wearable device for recording of biopotentials and body movements. Proceedings of the IEEE International Workshop on Medical Measurements and Applications (MeMeA), Bari, Italy. · DOI
  6. 2014, Embedded sensor systems for health - providing the tools in future healthcare, Stud. Health Technol. Inf., 200, 161
  7. Trobec, R., Tomašić, I., Rashkovska, A., Depolli, M., and Avbelj, V. (2018). Body Sensors and Electrocardiography, Springer. · DOI
  8. Meduri, 2010, A Smart ECG Measurement System Based on Web-Service-Oriented Architecture for Telemedicine Applications, IEEE Trans. Instrum. Meas., 59, 2530, 10.1109/TIM.2010.2057652 · DOI
  9. Trobec, 2014, Multi-functionality of wireless body sensors, IPSI BgD Trans. Internet Res., 10, 23
  10. Depolli, 2016, PCARD Platform for mHealth Monitoring, Informatica, 40, 117
  11. Trobec, R., Depolli, M., and Avbelj, V. (2010, January 3–5). Wireless network of bipolar body electrodes. Proceedings of the Seventh International Conference on Wireless On-demand Network Systems and Services (WONS), Kranjska Gora, Slovenia. · DOI
  12. Trobec, 2012, Two proximal skin electrodes–a respiration rate body sensor, Sensors, 12, 13813, 10.3390/s121013813 · doi:10.3390/s121013813
  13. Trobec, 2011, Synthesis of the 12-lead electrocardiogram from differential leads, IEEE Trans. Inf. Technol. Biomed., 15, 615, 10.1109/TITB.2011.2159236 · doi:10.1109/titb.2011.2159236
  14. Frljak, 2013, Estimating the universal positions of wireless body electrodes for measuring cardiac electrical activity, IEEE Trans. Inf. Technol. Biomed., 60, 3368, 10.1109/TBME.2013.2276291 · DOI
  15. Hansen, I.H., Hoppe, K., Gjerde, A., Kanters, J.K., and Sorensen, H.B.D. (2015, January 25–29). Comparing twelve-lead electrocardiography with close-to-heart patch based electrocardiography. Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy. · DOI
  16. Tomašić, I., Rashkovska, A., Trobec, R., and Lindén, M. (2018). The Implications of the Lead Theory on the Patch ECG Devices Positioning and Measurement. World Congress on Medical Physics and Biomedical Engineering, Springer. · DOI
  17. Rashkovska, A., and Avbelj, V. (2018, January 21–25). Three-year experience with a wireless ECG sensor. Proceedings of the 41st International Convention MIPRO, Opatija, Croatia. · DOI
  18. Rashkovska, A., and Avbelj, V. (2017, January 22–26). Abdominal fetal ECG measured with differential ECG Sensor. Proceedings of the 40th International Convention MIPRO, Opatija, Croatia. · doi:10.23919/mipro.2017.7973436
  19. Trobec, 2019, Quality of One-channel Telemetric ECG Sensor Signal in Maximum Exercise Stress Tests, Meas. Sci. Rev., 19, 79, 10.2478/msr-2019-0013 · DOI
  20. Porszasz, 2003, A treadmill ramp protocol using simultaneous changes in speed and grade, Med. Sci. Sports Exerc., 35, 1596, 10.1249/01.MSS.0000084593.56786.DA · DOI · Paper page
  21. Širaiy, B., Stanič, U.J., Poplas-Sušič, A., and Katkič, Z. (2018, January 21–25). Impact assessment of the morning gymnastics “1000 movements” via ECG and sport test. Proceedings of the 41st International Convention MIPRO, Opatija, Croatia. · DOI
  22. Krvavica, A., Likar, S., Brložnik, M., Domanjko-Petrič, A., and Avbelj, V. (June, January 30). Comparison of wireless electrocardiographic monitoring and standard ECG in dogs. Proceedings of the 39th International Convention MIPRO, Opatija, Croatia.
  23. Brložnik, M., and Avbelj, V. (2017, January 22–26). A case report of long-term wireless electrocardiographic monitoring in a dog with dilated cardiomyopathy. Proceedings of the 40th International Convention MIPRO, Opatija, Croatia. · DOI
  24. Likar, 2019, Wireless body sensor for electrocardiographic monitoring in dogs and cats, J. Small Anim. Pract., 60, 223, 10.1111/jsap.12963 · DOI
  25. Brložnik, M., Petric, A., Kos, V., Rashkovska, A., and Avbelj, V. (2019, January 20–24). Wireless body sensor for electrocardiographic monitoring in equine medicine. Proceedings of the 42nd International Convention MIPRO, Opatija, Croatia. · DOI
  26. Kocjančič, S., and Avbelj, V. (2018, January 8–12). Electrocardiographic sensor: How to use it among general physicians. Proceedings of the 21st International Multiconference Information Society-IS, Ljubljana, Slovenia.
  27. Čarman, D., Cvetkovič, T., Avbelj, V., and Kališnik, J. (2018, January 8–12). A study of postoperative atrial fibrillation. Proceedings of the 21st International Multiconference Information Society-IS, Ljubljana, Slovenia.
  28. Enova, D., Trobec, R., Mesarič, K., Slevec, K., Ambrožič, B., and Enova, T. (2018, January 8–12). New HRV biofeedback technique and monitoring its effects in a psychotherapeutic group of coronary patients with SAVVY mini ECG devices installed. Proceedings of the 21st International Multiconference Information Society-IS, Ljubljana, Slovenia.
  29. Šprager, S., Trobec, R., and Jurič, M. (2017, January 22–26). Feasibility of biometric authentication using wearable ECG body sensor based on higher-order statistics. Proceedings of the 40th International Convention MIPRO, Opatija, Croatia. · doi:10.23919/mipro.2017.7973431
  30. 2015, Inertial sensor-based gait recognition: A review, Sensors, 15, 22089, 10.3390/s150922089 · DOI · Paper page

Cited by

See all 65

Metadata

Authors
Rashkovska, A., Depolli, M., Tomašić, I., Avbelj, V., & Trobec, R.
Affiliations
  • Department of Communication Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
  • Division of Intelligent Future Technologies, Mälardalen University, Högskoleplan 1, 721 23 Västerås, Sweden
Venue
Sensors
Publisher
MDPI AG
Published
2020-03-18
Volume
20
Issue
6
Pages
1695
ISSN
1424-8220
Cited by
65
References
4
Language
en
Funders
  • Javna Agencija za Raziskovalno Dejavnost RS (P2-0095)
  • Stiftelsen för Kunskaps- och Kompetensutveckling (20180158)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical-Grade ECG Sensor for Long-Term Monitoring. https://app.cochat.ai/papers/10.3390/s20061695
The paper
Rashkovska, A., Depolli, M., Tomašić, I., Avbelj, V., & Trobec, R. (2020). Medical-Grade ECG Sensor for Long-Term Monitoring. Sensors. https://doi.org/10.3390/s20061695

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.