Cited by 25Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlEmotion and Mood Recognition

Comparison of Wearable and Clinical Devices for Acquisition of Peripheral Nervous System Signals

Open access
Bizzego, Andrea, Gabrieli, Giulio, Furlanello, Cesare, Esposito, Gianluca·2020·Sensors

Published version of a preprint

Abstract

A key access point to the functioning of the autonomic nervous system is the investigation of peripheral signals. Wearable devices (WDs) enable the acquisition and quantification of peripheral signals in a wide range of contexts, from personal uses to scientific research. WDs have lower costs and higher portability than medical-grade devices. However, the achievable data quality can be lower, and data are subject to artifacts due to body movements and data losses. It is therefore crucial to evaluate the reliability and validity of WDs before their use in research. In this study, we introduce a data analysis procedure for the assessment of WDs for multivariate physiological signals. The quality of cardiac and electrodermal activity signals is validated with a standard set of signal quality indicators. The pipeline is available as a collection of open source Python scripts based on the pyphysio package. We apply the indicators for the analysis of signal quality on data simultaneously recorded from a clinical-grade device and two WDs. The dataset provides signals of six different physiological measures collected from 18 subjects with WDs. This study indicates the need to validate the use of WDs in experimental settings for research and the importance of both technological and signal processing aspects to obtain reliable signals and reproducible results.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20236778

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Signal quality assessments have been done under more general circumstances, but wearable data quality in the context of epilepsy has not been a widely researched topic so far.

    “Signal quality assessments have been done under more general circumstances10,34–37, but wearable data quality in the context of epilepsy has not been a widely researched topic so far8,9,38.”

    From Data quality evaluation in wearable monitoring (2022) · cites this paper as [36]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 55 · Cited by 25

Research works printed but not linked: 1

  1. [23]Yadhuraj S. Harsha H. Motion Artifact Reduction in Photoplethysmographic Signals: A Review Int. J. Innov. Res. Dev. 2013 2 626 640

Authors
Bizzego, A., Gabrieli, G., Furlanello, C., & Esposito, G.
Affiliations
  • University of Trento (IT)
  • Nanyang Technological University (SG)
  • HK3 Lab, Rovereto, 38068 Trento, Italy
Corresponding author
Esposito, Gianluca
Venue
Sensors
Publisher
MDPI AG
Published
2020-11-27
Volume
20
Issue
23
Pages
6778
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3108311659
Cited by
25
References
55
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 8 · 2021: 9
FWCI
1.41
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Institutional Research Information System (Università degli Studi di Trento) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DR-NTU (Nanyang Technological University) (submittedVersion, cc-by)
Funders
Ministero dell'Istruzione, dell'Università e della Ricerca (Dipartimenti di Eccellenza)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
Keywords
wearable devices, autonomic nervous system, electrodermal activity, cardiac signals, signal quality assessment, signal quality indicators, device validation, body movement artifacts
MeSH terms
Wearable Electronic Devices, Autonomic Nervous System, Humans, Male, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review