Concise Historic Overview of Strain Sensors Used in the Monitoring of Civil Structures: The First One Hundred Years
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Strain is one of the most frequently monitored parameters in civil structural health monitoring (SHM) applications, and strain-based approaches were among the first to be explored and applied in SHM. There are multiple reasons why strain plays such an important role in SHM: strain is directly related to stress and deflection, which reflect structural performance, safety, and serviceability. Strain field anomalies are frequently indicators of unusual structural behaviors (e.g., damage or deterioration). Hence, the earliest concepts of strain sensing were explored in the mid-XIX century, the first effective strain sensor appeared in 1919, and the first onsite applications followed in the 1920′s. Today, one hundred years after the first developments, two generations of strain sensors, based on electrical and fiber-optic principles, firmly reached market maturity and established themselves as reliable tools applied in strain-based SHM. Along with sensor developments, the application methods evolved: the first generation of discrete sensors featured a short gauge length and provided a basis for local material monitoring; the second generation greatly extended the applicability and effectiveness of strain-based SHM by providing long gauge and one-dimensional (1D) distributed sensing, thus enabling global structural and integrity monitoring. Current research focuses on a third generation of strain sensors for two-dimensional (2D) distributed and quasi-distributed sensing, based on new advanced technologies. On the occasion of strain sensing centenary, and as an homage to all researchers, practitioners, and educators who contributed to strain-based SHM, this paper presents an overview of the first one hundred years of strain sensing technological progress, with the objective to identify relevant transformative milestones and indicate possible future research directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malekloo, A., Ozer, E., AlHamaydeh, M., & Girolami, M. (2022) · Structural Health Monitoring · doi:10.1177/14759217211036880 · Cited by 607
Cited by
Ju, M., Dou, Z., Li, J.-W., Qiu, X., Shen, B., Zhang, D., Yao, F.-Z., Gong, W., & Wang, K. (2023) · Sensors · doi:10.3390/s23010543 · Cited by 277
Digital Twin for Civil Engineering Systems: An Exploratory Review for Distributed Sensing Updating
Bado, M. F., Tonelli, D., Poli, F., Zonta, D., & Casas, J. R. (2022) · Sensors · doi:10.3390/s22093168 · Cited by 158
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review
Sun, Z., Mahmoodian, M., Sidiq, A., Jayasinghe, S., Shahrivar, F., & Setunge, S. (2025) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan14020022 · Cited by 53
Metadata
- Authors
- Glisic, B.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2022-03-20
- Volume
- 22
- Issue
- 6
- Pages
- 2397
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W4220857649
- Cited by
- 99
- References
- 1
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.