Cited by 8Gas Sensing Nanomaterials and SensorsAdvanced Chemical Sensor TechnologiesSensor Technology and Measurement Systems

A Low-Current and Multi-Channel Chemiresistor Array Sensor Device

Open access
Wang, Zaiqi, Shang, Guojun, Dinh, Dong, Yan, Shan, Luo, Jin, Huang, Aimin, Yang, Lefu, Lu, Susan, Zhong, Chuan-Jian·2022·Sensors

Abstract

This paper describes the design of a low-current, multichannel, handheld electronic device integrated with nanostructured chemiresistor sensor arrays. A key design feature of the electronic circuit board is its low excitation current for achieving optimal performance with the arrays. The electronics can rapidly acquire the resistances for different sensors, not only spanning several orders of magnitude, but also as high as several hundreds of megaohms. The device tested is designed using a chemiresistor array with nanostructured sensing films prepared by molecularly-mediated assemblies of gold nanoparticles for detection. The low-current, wide-range, and auto-locking capabilities, along with the effective coupling with the nanostructured chemiresistor arrays, meet the desired performances of a low excitation current and low power consumption, and also address the potential instability of the sensors in a complex sensing environment. The results are promising for potential applications of the device as a portable sensor for the point-of-need monitoring of air quality and as a biosensor for point-of-care human breath screening for disease biomarkers.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s22072781

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 26 · Cited by 8

Authors
Wang, Z., Shang, G., Dinh, D., Yan, S., Luo, J., Huang, A., Yang, L., Lu, S., & Zhong, C.-J.
Affiliations
  • Xiamen Institute of Measurement and Testing, Xiamen 361004, China
  • Binghamton University (US)
  • Xiamen Smart NanoSensing Technologies, Xiamen 361021, China
Corresponding author
Zhong, Chuan-Jian
Venue
Sensors
Publisher
MDPI AG
Published
2022-04-05
Volume
22
Issue
7
Pages
2781
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4223585884
Cited by
8
References
26
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 1
FWCI
0.41
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Science Foundation (2102482 and IIP 1640669)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
  • Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
Keywords
gold nanoparticles, low power consumption, air quality monitoring, point-of-care biosensing, disease biomarkers
MeSH terms
Electronics, Gold, Humans, Biosensing Techniques, Metal Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›