Cited by 84Ultrasonics and Acoustic Wave PropagationAcoustic Wave Resonator TechnologiesAdvanced MEMS and NEMS Technologies

The DOI matches its Crossref record.

Piezoelectric Micromachined Ultrasonic Transducers (PMUTs): Performance Metrics, Advancements, and Applications

Open access

Abstract

With the development of technology, systems gravitate towards increasing in their complexity, miniaturization, and level of automation. Amongst these systems, ultrasonic devices have adhered to this trend of advancement. Ultrasonic systems require transducers to generate and sense ultrasonic signals. These transducers heavily impact the system’s performance. Advancements in microelectromechanical systems have led to the development of micromachined ultrasonic transducers (MUTs), which are utilized in miniaturized ultrasound systems. Piezoelectric micromachined ultrasonic transducers (PMUTs) exhibit higher capacitance and lower electrical impedance, which enhances the transducer’s sensitivity by minimizing the effect of parasitic capacitance and facilitating their integration with low-voltage electronics. PMUTs utilize high-yield batch microfabrication with the use of thin piezoelectric films. The deposition of thin piezoelectric material compatible with complementary metal-oxide semiconductors (CMOS) has opened novel avenues for the development of miniaturized compact systems with the same substrate for application and control electronics. PMUTs offer a wide variety of applications, including medical imaging, fingerprint sensing, range-finding, energy harvesting, and intrabody and underwater communication links. This paper reviews the current research and recent advancements on PMUTs and their applications. This paper investigates in detail the important transduction metrics and critical design parameters for high-performance PMUTs. Piezoelectric materials and microfabrication processes utilized to manufacture PMUTs are discussed. Promising PMUT applications and outlook on future advancements are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s22239151

Cites

Statistics

Figures

Figure 1 Schematic view of Electric dipole moments in (a) unpolarized piezoelectric material and (b) polarized piezoelectric material in the presence of an electric field.
Figure 1 Schematic view of Electric dipole moments in (a) unpolarized piezoelectric material and (b) polarized piezoelectric material in the presence of an electric field.CC BY · PubMed Central
Figure 2 Schematic side view of a piezoelectric micromachined ultrasonic transducer (PMUT) cell.
Figure 2 Schematic side view of a piezoelectric micromachined ultrasonic transducer (PMUT) cell.CC BY · PubMed Central
Figure 3 (a,b) Three-dimensional perspectives of PMUT cell.
Figure 3 (a,b) Three-dimensional perspectives of PMUT cell.CC BY · PubMed Central
Figure 4 Mass–spring–damper system.
Figure 4 Mass–spring–damper system.CC BY · PubMed Central
Figure 5 PMUT-equivalent circuit model.
Figure 5 PMUT-equivalent circuit model.CC BY · PubMed Central
Figure 6 PMUT fabrication using the back-side etching process. (a) (100) Si wafer as a substrate, (b) Wet oxidation, (c) SiO2 etching using BOE, (d) Boron diffusion, (e) Formation of sacrificial layer by LTO, (f) Oxide etch using BOE, (g) Si etching by EDP, (h) Bottom electrode Ti–Pt deposition by e-beam evaporation, (i) PZT deposition by sol-gel technique, (j) Top electrode TiW–Au deposition by sputtering, (k) Top electrode etching using KI3 and H2, (l) PZT etching using HCl:HF:H2O.
Figure 6 PMUT fabrication using the back-side etching process. (a) (100) Si wafer as a substrate, (b) Wet oxidation, (c) SiO2 etching using BOE, (d) Boron diffusion, (e) Formation of sacrificial layer by LTO, (f) Oxide etch using BOE, (g) Si etching by EDP, (h) Bottom electrode Ti–Pt deposition by e-beam evaporation, (i) PZT deposition by sol-gel technique, (j) Top electrode TiW–Au deposition by sputtering, (k) Top electrode etching using KI3 and H2, (l) PZT etching using HCl:HF:H2O.CC BY · PubMed Central
Figure 7 PMUT fabrication procedure for defining diaphragm via front-side etching technique. (a) RF sputter deposition applies a thick coat of PZT and a Pt electrode top-layer on a silicon wafer layered with SiO2 and Ti/Pt. (b) Reactive ion etching (RIE) exposes the Ti/Pt electrode and patterns the Pt top-layer along with contact lithography. (c) A layer of SiO2 is applied as an insulation pad via sputter deposition and lift-off to prepare for the fabrication of the electrode fan-out. (d) A conformal connection is formed using sputtered and patterned Ti/Pt. (e) Access to the bottom Si layer diaphragm is created by means of an etch via through the Pt, PZT, Ti/Pt, and SiO2 stack. (f) The diaphragm is then laminated with negative photoresist film (MX5015) and coated with parylene to seal the vias.
Figure 7 PMUT fabrication procedure for defining diaphragm via front-side etching technique. (a) RF sputter deposition applies a thick coat of PZT and a Pt electrode top-layer on a silicon wafer layered with SiO2 and Ti/Pt. (b) Reactive ion etching (RIE) exposes the Ti/Pt electrode and patterns the Pt top-layer along with contact lithography. (c) A layer of SiO2 is applied as an insulation pad via sputter deposition and lift-off to prepare for the fabrication of the electrode fan-out. (d) A conformal connection is formed using sputtered and patterned Ti/Pt. (e) Access to the bottom Si layer diaphragm is created by means of an etch via through the Pt, PZT, Ti/Pt, and SiO2 stack. (f) The diaphragm is then laminated with negative photoresist film (MX5015) and coated with parylene to seal the vias.CC BY · PubMed Central
Figure 8 Multiple-electrode PMUT. (a) Top view of four-electrode PMUT, (b) Cross section side view of four-electrode PMUT.
Figure 8 Multiple-electrode PMUT. (a) Top view of four-electrode PMUT, (b) Cross section side view of four-electrode PMUT.CC BY · PubMed Central
Figure 9 (a) Cross-sectional side view of dome-shaped PMUT; (b) 3D view of dome-shaped PMUT.
Figure 9 (a) Cross-sectional side view of dome-shaped PMUT; (b) 3D view of dome-shaped PMUT.CC BY · PubMed Central
Figure 10 (a) PMUT with differential transduction; (b) PMUT with series transduction.
Figure 10 (a) PMUT with differential transduction; (b) PMUT with series transduction.CC BY · PubMed Central
Figure 11 Rectangular PMUT with a large aspect ratio (mode-merging PMUT).
Figure 11 Rectangular PMUT with a large aspect ratio (mode-merging PMUT).CC BY · PubMed Central
Figure 12 Three-dimensional cross-sectional side view of PMUT with backing layer.
Figure 12 Three-dimensional cross-sectional side view of PMUT with backing layer.CC BY · PubMed Central
Figure 13 (a) Three-dimensional cross-sectional view of PMUT with venting rings. (b) Cross-sectional view of PMUT with venting rings with MEMS bond on CMOS.
Figure 13 (a) Three-dimensional cross-sectional view of PMUT with venting rings. (b) Cross-sectional view of PMUT with venting rings with MEMS bond on CMOS.CC BY · PubMed Central
Figure 14 (a) Cross-sectional view of curved PMUT with concave diaphragm. (b) Cross-sectional view of stress engineered self-curved PMUT with concave diaphragm.
Figure 14 (a) Cross-sectional view of curved PMUT with concave diaphragm. (b) Cross-sectional view of stress engineered self-curved PMUT with concave diaphragm.CC BY · PubMed Central
Figure 15 Three-dimensional schematic of a PMUT array based on cavity SOI.
Figure 15 Three-dimensional schematic of a PMUT array based on cavity SOI.CC BY · PubMed Central
Figure 16 (a) Top view of PMUT cells with release holes on the edges, (b) cross-sectional view of fabricated PMUT cells with SOI substrate.
Figure 16 (a) Top view of PMUT cells with release holes on the edges, (b) cross-sectional view of fabricated PMUT cells with SOI substrate.CC BY · PubMed Central
Figure 17 Three-dimensional cross-sectional view of PMUT array illustrating structure details and magnified view of etch holes.
Figure 17 Three-dimensional cross-sectional view of PMUT array illustrating structure details and magnified view of etch holes.CC BY · PubMed Central
Figure 18 Beamforming using sub-array groups of 15 PMUT elements.
Figure 18 Beamforming using sub-array groups of 15 PMUT elements.CC BY · PubMed Central
Figure 19 Schematic view of a PMUT array structure functionalized with a graphene oxide sensing layer.
Figure 19 Schematic view of a PMUT array structure functionalized with a graphene oxide sensing layer.CC BY · PubMed Central
Figure 20 Schematic view of a PDMS-microchannel-integrated structure comprising dual-electrode PMUT elements.
Figure 20 Schematic view of a PDMS-microchannel-integrated structure comprising dual-electrode PMUT elements.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 108

  1. Lethiecq, M., Levassort, F., Certon, D., and Tran-Huu-Hue, L.P. (2008). Piezoelectric Transducer Design for Medical Diagnosis and NDE. Piezoelectric and Acoustic Materials for Transducer Applications, Springer. · DOI
  2. Akasheh, 2004, Development of Piezoelectric Micromachined Ultrasonic Transducers, Sens. Actuators A Phys., 111, 275, 10.1016/j.sna.2003.11.022 · DOI
  3. Aldrich, 2007, Basic Physics of Ultrasound Imaging, Crit. Care Med., 35, S131, 10.1097/01.CCM.0000260624.99430.22 · DOI
  4. Zhou, 2014, Piezoelectric Single Crystal Ultrasonic Transducers for Biomedical Applications, Prog. Mater. Sci., 66, 87, 10.1016/j.pmatsci.2014.06.001 · DOI
  5. Muralt, P., and Baborowski, J. (2004). Micromachined Ultrasonic Transducers and Acoustic Sensors Based on Piezoelectric Thin Films, Kluwer Academic Publishers. · DOI
  6. 2002, Piezoelectrically Actuated Flextensional Micromachined Ultrasound Transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 49, 585, 10.1109/TUFFC.2002.1002457 · DOI
  7. Heywang, W., Lubitz, K., and Wersing, W. (2008). Piezoelectricity, Springer. · DOI
  8. Dangi, 2015, Complete Development of a Single Cell PMUT Transducer: Design, Fabrication, Characterization, and Integration, J. Inst. Smart Struct. Syst., 4, 61
  9. Jung, 2017, Review of Piezoelectric Micromachined Ultrasonic Transducers and Their Applications, J. Micromech. Microeng., 27, 113001, 10.1088/1361-6439/aa851b · DOI
  10. Sherman, C.H., and Butler, J.L. (2007). Transducers and Arrays for Underwater Sound, Springer. · DOI
  11. Sadeghpour, S., Pobedinskas, P., Haenen, K., and Puers, R. (2017). A Piezoelectric Micromachined Ultrasound Transducers (PMUT) Array, for Wide Bandwidth Underwater Communication Applications. Proceedings, 1. · DOI
  12. Qiu, 2015, Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging, Sensors, 15, 8020, 10.3390/s150408020 · DOI
  13. Yamashita, 2002, Arrayed Ultrasonic Microsensors with High Directivity for In-Air Use Using PZT Thin Film on Silicon Diaphragms, Sens. Actuators A Phys., 97–98, 302, 10.1016/S0924-4247(02)00037-7 · DOI
  14. Kusano, 2018, Effects of DC Bias Tuning on Air-Coupled PZT Piezoelectric Micromachined Ultrasonic Transducers, J. Microelectromech. Syst., 27, 296, 10.1109/JMEMS.2018.2797684 · DOI
  15. Mitchell, 1987, A Simple Frequency Formula for Clamped Rectangular Plates, J. Sound Vib., 118, 271, 10.1016/0022-460X(87)90525-6 · DOI
  16. Shelton, S., Chan, M.L., Park, H., Horsley, D., Boser, B., Izyumin, I., Przybyla, R., Frey, T., Judy, M., and Nunan, K. (2009, January 20–23). CMOS-Compatible AlN Piezoelectric Micromachined Ultrasonic Transducers. Proceedings of the 2009 IEEE International Ultrasonics Symposium, Rome, Italy. · DOI
  17. Cho, 2005, Optimization of Electromechanical Coupling for a Thin-Film PZT Membrane: II. Experiment, J. Micromech. Microeng., 15, 1804, 10.1088/0960-1317/15/10/003 · DOI
  18. Cho, 2005, Optimization of Electromechanical Coupling for a Thin-Film PZT Membrane: I. Modeling, J. Micromech. Microeng., 15, 1797, 10.1088/0960-1317/15/10/002 · DOI
  19. Jung, 2013, Fabrication of a Two-Dimensional Piezoelectric Micromachined Ultrasonic Transducer Array Using a Top-Crossover-to-Bottom Structure and Metal Bridge Connections, J. Micromech. Microeng., 23, 125037, 10.1088/0960-1317/23/12/125037 · DOI
  20. Amar, 2017, Modeling and Process Design Optimization of a Piezoelectric Micromachined Ultrasonic Transducers (PMUT) Using Lumped Elements Parameters, Microsyst. Technol., 23, 4659, 10.1007/s00542-016-3205-8 · DOI
  21. Mo, 1990, Micromachining for Improvement of Integrated Ultrasonic Transducer Sensitivity, IEEE Trans. Electron. Devices, 37, 134, 10.1109/16.43810 · DOI
  22. Guedes, A., Shelton, S., Przybyla, R., Izyumin, I., Boser, B., and Horsley, D.A. (2011, January 5–9). Aluminum Nitride PMUT Based on a Flexurally-Suspended Membrane. Proceedings of the 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, Beijing, China. · DOI
  23. Zhou, 2011, Piezoelectric Films for High Frequency Ultrasonic Transducers in Biomedical Applications, Prog. Mater. Sci., 56, 139, 10.1016/j.pmatsci.2010.09.001 · DOI
  24. Holz, 2014, Integration of PVDF (Polyvinylidene Fluoride) in MEMS Production, ECS Trans., 64, 189, 10.1149/06401.0189ecst · DOI
  25. Setter, 2006, Ferroelectric Thin Films: Review of Materials, Properties, and Applications, J. Appl. Phys., 100, 051606, 10.1063/1.2336999 · DOI
  26. Tadigadapa, 2009, Piezoelectric MEMS Sensors: State-of-the-Art and Perspectives, Meas. Sci. Technol., 20, 092001, 10.1088/0957-0233/20/9/092001 · DOI
  27. Dausch, 2014, In Vivo Real-Time 3-D Intracardiac Echo Using PMUT Arrays, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 61, 1754, 10.1109/TUFFC.2014.006452 · DOI
  28. Muralt, 2004, Thin Film Piezoelectrics for MEMS, J. Electroceram., 12, 7, 10.1023/B:JECR.0000033998.72845.51 · DOI
  29. Dangi, 2020, A Photoacoustic Imaging Device Using Piezoelectric Micromachined Ultrasound Transducers (PMUTs), IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 67, 801, 10.1109/TUFFC.2019.2956463 · DOI
  30. Wang, 2021, Development of Dual-Frequency PMUT Arrays Based on Thin Ceramic PZT for Endoscopic Photoacoustic Imaging, J. Microelectromech. Syst., 30, 770, 10.1109/JMEMS.2021.3096733 · DOI
  31. Liu, 2022, Fabrication and Characterization of Row-Column Addressed PMUT Array with Monocrystalline PZT Thin Film toward Creating Ultrasonic Imager, Sens. Actuators A Phys., 342, 113666, 10.1016/j.sna.2022.113666 · DOI
  32. Safari, A., and Akdoǧan, E.K. (2008). Piezoelectric and Acoustic Materials for Transducer Applications, Springer. · DOI
  33. Kholkin, 2013, Piezoelectric Materials and DevicesApplications in Engineering and Medical Science, Mater. Today, 16, 94, 10.1016/j.mattod.2013.03.001 · DOI
  34. Ledesma, E., Zamora, I., Uranga, A., Torres, F., and Barniol, N. (2021). Enhancing Aln Pmuts’ Acoustic Responsivity within a Mems-on-Cmos Process. Sensors, 21. · DOI
  35. Pandian, M.S., Ferrer, E.M., Tay, W.S., Madhaven, V., Kantimahanti, A.K., Sobreviela, G., Uranga, A., and Barniol, N. (2016, January 21–24). Thin Film Piezoelectric Devices Integrated on CMOS. Proceedings of the 2016 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA), Xi’an, China.
  36. Tsai, J.M., Daneman, M., Boser, B., Horsley, D., Rais-Zadeh, M., Tang, H.Y., Lu, Y., Rozen, O., Liu, F., and Lim, M. (2015, January 21–25). Versatile CMOS-MEMS Integrated Piezoelectric Platform. Proceedings of the 2015 Transducers—2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS, Anchorage, AK, USA. · DOI
  37. Dubois, 1999, Properties of Aluminum Nitride Thin Films for Piezoelectric Transducers and Microwave Filter Applications, Appl. Phys. Lett., 74, 3032, 10.1063/1.124055 · DOI
  38. Ballato, A., Gualtieri, J.G., and Kosinski, J.A. (1994, January 7–10). Ferroelectric Materials for Thin-Film and Membrane Resonators. Proceedings of the IEEE International Symposium on Applications of Ferroelectrics, University Park, PA, USA.
  39. Wang, 2005, Fabrication and Characterization of Piezoelectric Micromachined Ultrasonic Transducers with Thick Composite PZT Films, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 52, 2289, 10.1109/TUFFC.2005.1563271 · DOI
  40. Muralt, 2005, Piezoelectric Micromachined Ultrasonic Transducers Based on PZT Thin Films, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 52, 2276, 10.1109/TUFFC.2005.1563270 · DOI
  41. Dausch, 2008, Theory and Operation of 2-D Array Piezoelectric Micromachined Ultrasound Transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 55, 2484, 10.1109/TUFFC.956 · DOI
  42. Griggio, F., Demore, C.E.M., Kim, H., Gigliotti, J., Qiu, Y., Jackson, T.N., Choi, K., Tutwiler, R.L., Cochran, S., and Trolier-Mckinstry, S. (2012, January 7–10). Micromachined Diaphragm Transducers for Miniaturised Ultrasound Arrays. Proceedings of the IEEE International Ultrasonics Symposium, Dresden, Germany. · DOI
  43. Akai, D., Yogi, T., Kamja, I., Numata, Y., Ozaki, K., Sawada, K., Okada, N., Higuchi, K., and Ishida, M. (2011, January 5–9). Miniature Ultrasound Acoustic Imaging Devices Using 2-D PMUTs Array on Epitaxial PZT/SrRuO3/Pt/-Al2O3/Si Structure. Proceedings of the 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, Beijing, China.
  44. Atalar, 1998, Micromachined Two-Dimensional Array Piezoelectrically Actuated Transducers, Appl. Phys. Lett., 72, 1397, 10.1063/1.121067 · DOI
  45. Percin, G., and Khuri-Yakub, B.T. (1997, January 5–8). Micromachined 2-D Array Piezoelectrically Actuated Flextensional Transducers. Proceedings of the IEEE Ultrasonics Symposium, Toronto, ON, Canada. · DOI
  46. Smyth, K.M., Sodini, C.G., and Kim, S.G. (2017, January 18–22). High Electromechanical Coupling Piezoelectric Micro-Machined Ultrasonic Transducer (PMUT) Elements for Medical Imaging. Proceedings of the TRANSDUCERS 2017—19th International Conference on Solid-State Sensors, Actuators and Microsystems, Kaohsiung, Taiwan. · DOI
  47. Lu, Y., Heidari, A., Shelton, S., Guedes, A., and Horsley, D.A. (2014, January 26–30). High Frequency Piezoelectric Micromachined Ultrasonic Transducer Array for Intravascular Ultrasound Imaging. Proceedings of the IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS), San Francisco, CA, USA. · DOI
  48. Meyers, 2019, High-Frequency Oscillatory Ventilation: A Narrative Review, Can. J. Respir. Ther., 55, 40, 10.29390/cjrt-2019-004 · DOI
  49. Ledesma, E., Tzanov, V., Zamora, I., Torres, F., Uranga, A., Barniol, N., Marigo, E., and Soundara-Pandian, M. (2019, January 23–27). ALN Pmut with Crossed-Cavity for Better Acoustic Pressure Outputs in Liquid at High Frequency. Proceedings of the 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (Transducers & Eurosensors XXXIII), Berlin, Germany. · DOI
  50. Smyth, 2015, Experiment and Simulation Validated Analytical Equivalent Circuit Model for Piezoelectric Micromachined Ultrasonic Transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 62, 744, 10.1109/TUFFC.2014.006725 · DOI
  51. Wang, Q., Lu, Y., Fung, S., Jiang, X., Mishin, S., Oshmyansky, Y., and Horsley, D.A. (2016, January 5–9). Scandium Doped Aluminum Nitride Based Piezoelectric Micromachined Ultrasound Transducers. Proceedings of the 2016 Solid-State Sensors, Actuators and Microsystems Workshop, Hilton Head, SC, USA. · DOI
  52. Guo, J.Q., Liu, C.C., Han, T., and Miao, J.M. (2017, January 27–30). Model of Scandium Doped Aluminum Nitride Based PMUT with High Transmitting Performance. Proceedings of the 2017 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications, SPAWDA, Chengdu, China. · DOI
  53. Sammoura, F., Akhari, S., Aqab, N., Mahmoud, M., and Lin, L. (2014, January 3–6). Multiple Electrode Piezoelectric Micromachined Ultrasonic Transducers. Proceedings of the IEEE International Ultrasonics Symposium, Chicago, IL, USA. · DOI
  54. Akhbari, S., Sammoura, F., Shelton, S., Yang, C., Horsley, D., and Lin, L. (2014, January 26–30). Highly Responsive Curved Aluminum Nitride PMUT. Proceedings of the IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS), San Francisco, CA, USA. · DOI
  55. Feng, 2005, Fabrication of MEMS ZnO Dome-Shaped-Diaphragm Transducers for High-Frequency Ultrasonic Imaging, J. Micromech. Microeng., 15, 586, 10.1088/0960-1317/15/3/021 · DOI
  56. Hajati, 2012, Three-Dimensional Micro Electromechanical System Piezoelectric Ultrasound Transducer, Appl. Phys. Lett., 101, 253101, 10.1063/1.4772469 · DOI
  57. Sammoura, 2014, An Analytical Solution for Curved Piezoelectric Micromachined Ultrasonic Transducers with Spherically Shaped Diaphragms, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 61, 1533, 10.1109/TUFFC.2014.3067 · DOI
  58. Lu, Y., Wang, Q., and Horsley, D.A. (2015, January 21–24). Piezoelectric Micromachined Ultrasonic Transducers with Increased Coupling Coefficient via Series Transduction. Proceedings of the 2015 IEEE International Ultrasonics Symposium, Taipei, Taiwan. · DOI
  59. Lu, 2015, Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers, J. Microelectromech. Syst., 24, 1142, 10.1109/JMEMS.2014.2387154 · DOI
  60. Wang, T., Kobayashi, T., and Lee, C. (2015, January 7–11). Broadband Piezoelectric Micromachined Ultrasonic Transducer (PMUT) Using Mode-Merged Design. Proceedings of the 2015 IEEE 10th International Conference on Nano/Micro Engineered and Molecular Systems, Xi’an, China.
  61. Eovino, B.E., Akhbari, S., and Lin, L. (2017, January 22–26). Broadband Ring-Shaped PMUTS Based on an Acoustically Induced Resonance. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Las Vegas, NV, USA. · DOI
  62. Wang, X.B., He, L.M., Ma, Y.C., Liu, W.J., Xu, W.J., Ren, J.Y., Riaud, A., and Zhou, J. (2021). Development of Broadband High-Frequency Piezoelectric Micromachined Ultrasonic Transducer Array. Sensors, 21. · DOI
  63. Horsley, D., Lu, Y., and Rozen, O. (2017). Flexural Piezoelectric Resonators. Piezoelectric MEMS Resonators, Springer. · DOI
  64. Wang, 2016, Enhancement of the Transmission of Piezoelectric Micromachined Ultrasonic Transducer with an Isolation Trench, J. Microelectromech. Syst., 25, 691, 10.1109/JMEMS.2016.2577038 · DOI
  65. Liang, Y., Eovino, B.E., and Lin, L. (2019, January 27–31). Pinned Boundary Piezoelectric Micromachined Ultrasonic Transducers. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Seoul, Republic of Korea. · DOI
  66. Rozen, O., Block, S.T., Shelton, S.E., and Horsley, D.A. (2015, January 21–25). Piezoelectric Micromachined Ultrasonic Transducer with Increased Output Pressure via Concentric Venting Rings. Proceedings of the 2015 Transducers—18th International Conference on Solid-State Sensors, Actuators and Microsystems, Anchorage, AK, USA. · DOI
  67. Akhbari, 2016, Equivalent Circuit Models for Large Arrays of Curved and Flat Piezoelectric Micromachined Ultrasonic Transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 63, 432, 10.1109/TUFFC.2016.2525802 · DOI
  68. Lu, 2015, A High Fill-Factor Annular Array of High Frequency Piezoelectric Micromachined Ultrasonic Transducers, J. Microelectromech. Syst., 24, 904, 10.1109/JMEMS.2014.2358991 · DOI
  69. Akhbari, S., Sammoura, F., Yang, C., Heidari, A., Horsley, D., and Lin, L. (2015, January 18–22). Self-Curved Diaphragms by Stress Engineering for Highly Responsive PMUT. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Estoril, Portugal. · DOI
  70. Chen, 2017, Large-Scale and High-Density PMUT Array Based on Isolated Sol-Gel PZT Membranes for Fingerprint Imaging, J. Electrochem. Soc., 164, B377, 10.1149/2.0891707jes · DOI
  71. Jiao, 2020, High Fill Factor Array of Piezoelectric Micromachined Ultrasonic Transducers with Large Quality Factor, Sens. Mater., 32, 1785
  72. Rozen, O., Block, S.T., Mo, X., Bland, W., Hurst, P., Tsai, J.M., Daneman, M., Amirtharajah, R., and Horsley, D.A. (2016, January 24–28). Monolithic MEMS-CMOS Ultrasonic Rangefinder Based on Dual-Electrode PMUTs. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China. · DOI
  73. Wang, T., and Lee, C. (2016, January 24–28). Electrically Switchable Multi-Frequency Piezoelectric Micromachined Ultrasonic Transducer (PMUT). Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China. · DOI
  74. Kazari, 2019, Multi-Frequency Piezoelectric Micromachined Ultrasonic Transducers, IEEE Sens. J., 19, 11090, 10.1109/JSEN.2019.2935158 · DOI
  75. Liu, 2021, A Dual-Frequency Piezoelectric Micromachined Ultrasound Transducer Array with Low Inter-Element Coupling Effects, J. Micromech. Microeng., 31, 045005, 10.1088/1361-6439/abde8f · DOI
  76. Lu, 2015, Ultrasonic Fingerprint Sensor Using a Piezoelectric Micromachined Ultrasonic Transducer Array Integrated with Complementary Metal Oxide Semiconductor Electronics, Appl. Phys. Lett., 106, 3503, 10.1063/1.4922915 · DOI
  77. Wang, 2015, Zero-Bending Piezoelectric Micromachined Ultrasonic Transducer (PMUT) With Enhanced Transmitting Performance, J. Microelectromech. Syst., 24, 2083, 10.1109/JMEMS.2015.2472958 · DOI
  78. Lu, 2016, Pulse-Echo Ultrasound Imaging Using an AlN Piezoelectric Micromachined Ultrasonic Transducer Array with Transmit Beam-Forming, J. Microelectromech. Syst., 25, 179, 10.1109/JMEMS.2015.2503336 · DOI
  79. Jiang, 2017, Ultrasonic Fingerprint Sensor with Transmit Beamforming Based on a PMUT Array Bonded to CMOS Circuitry, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 64, 1401, 10.1109/TUFFC.2017.2703606 · DOI
  80. Sun, 2019, Investigation of Broadband Characteristics of Multi-Frequency Piezoelectric Micromachined Ultrasonic Transducer (MF-PMUT), IEEE Sens. J., 19, 860, 10.1109/JSEN.2018.2878785 · DOI
  81. Wang, H., Yang, H., Jiang, H., Chen, Z., Feng, P.X.L., and Xie, H. (2021, January 20–24). A Multi-Frequency PMUT Array Based on Ceramic PZT for Endoscopic Photoacoustic Imaging. Proceedings of the 21st International Conference on Solid-State Sensors, Actuators and Microsystems, Orlando, FL, USA. · DOI
  82. Kim, E.S., Muller, R.S., and Gray, P.R. (1989, January 3–6). Integrated Microphone with CMOS Circuits on a Single Chip. Proceedings of the International Technical Digest on Electron Devices Meeting, Washington, DC, USA.
  83. Zamora, I., Ledesma, E., Uranga, A., and Barniol, N. (2020). Miniaturized 0.13-μm CMOS Front-End Analog for AlN PMUT Arrays. Sensors, 20. · DOI
  84. Zamora, 2020, Monolithic Single PMUT-on-CMOS Ultrasound System with +17 DB SNR for Imaging Applications, IEEE Access, 8, 142785, 10.1109/ACCESS.2020.3013763 · DOI
  85. Oralkan, 2009, Next-Gen Ultrasound, IEEE Spectr., 46, 44, 10.1109/MSPEC.2009.4907385 · DOI
  86. Billen, M., Gao, H., Tabruyn, D., Marigo, E., Soundara-Pandian, M., Helin, P., and Rochus, V. (2021, January 25–29). Multi-Frequency Imaging with a CMOS Compatible Scandium Doped Aluminum Nitride PMUT Array. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Gainesville, FL, USA. · DOI
  87. Savoia, A.S., Casavola, M., Boni, E., Ferrera, M., Prelini, C., Tortoli, P., Giusti, D., and Quaglia, F. (2021, January 11–16). Design, Fabrication, Characterization, and System Integration of a 1-D PMUT Array for Medical Ultrasound Imaging. Proceedings of the IEEE International Ultrasonics Symposium, IUS, Xi’an, China. · DOI
  88. Boni, E., Bassi, L., Dallai, A., Giannini, G., Guidi, F., Meacci, V., Matera, R., Ramalli, A., Ricci, S., and Scaringella, M. (2015, January 21–24). ULA-OP 256: A Portable High-Performance Research Scanner. Proceedings of the 2015 IEEE International Ultrasonics Symposium, Taipei, Taiwan. · DOI
  89. Attia, 2019, A Review of Clinical Photoacoustic Imaging: Current and Future Trends, Photoacoustics, 16, 100144, 10.1016/j.pacs.2019.100144 · DOI
  90. Cai, J., Wang, Y., Jiang, D., Gu, Y., Lou, L., Gao, F., and Wu, T. (2022). Photoacoustic Imaging Based on AlN MF-PMUT with Broadened Bandwidth. arXiv.
  91. Nazemi, H., Balasingam, J.A., Swaminathan, S., Ambrose, K., Nathani, M.U., Ahmadi, T., Lopez, Y.B., and Emadi, A. (2020). Mass Sensors Based on Capacitive and Piezoelectric Micromachined Ultrasonic Transducers—CMUT and PMUT. Sensors, 20. · DOI
  92. Balasingam, J.A., Swaminathan, S., Nazemi, H., Love, C., Birjis, Y., and Emadi, A. (2021). Chemical Sensors: Gas Sensors, Acoustic Sensors. Reference Module in Biomedical Sciences, Elsevier.
  93. Sun, C., Shi, Q., Yazici, M.S., Lee, C., and Liu, Y. (2018). Development of a Highly Sensitive Humidity Sensor Based on a Piezoelectric Micromachined Ultrasonic Transducer Array Functionalized with Graphene Oxide Thin Film. Sensors, 18. · DOI
  94. Tang, 2015, Highly Sensitive Surface Acoustic Wave (SAW) Humidity Sensors Based on Sol-Gel SiO2 Films: Investigations on the Sensing Property and Mechanism, Sens. Actuators B Chem., 215, 283, 10.1016/j.snb.2015.03.069 · DOI
  95. Qiu, 2010, Experiment and Theoretical Analysis of Relative Humidity Sensor Based on Film Bulk Acoustic-Wave Resonator, Sens. Actuators B Chem., 147, 381, 10.1016/j.snb.2010.04.012 · DOI
  96. Roy, 2020, Fluid Density Sensing Using Piezoelectric Micromachined Ultrasound Transducers, IEEE Sens. J., 20, 6802, 10.1109/JSEN.2019.2936469 · DOI
  97. Roy, K., Gupta, H., Shastri, V., Dangi, A., and Pratap, R. (2018, January 28–31). Fluid Density Sensing Using PMUTs. Proceedings of the IEEE Sensors, New Delhi, India. · DOI
  98. Roy, K., Mandal, A., Ashok, A., Gupta, H., Shastri, V., and Pratap, R. (2020, January 7–11). A Single Cell PMUT as a Bio-Fluid Density Sensor. Proceedings of the IEEE International Ultrasonics Symposium, IUS, Las Vegas, NV, USA. · DOI
  99. Roy, 2021, A PMUT Integrated Microfluidic System for Fluid Density Sensing, J. Microelectromech. Syst., 30, 642, 10.1109/JMEMS.2021.3091651 · DOI
  100. Zhang, 1999, Electromechanical Properties of Lead Zirconate Titanate Piezoceramics under the Influence of Mechanical Stresses, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 46, 1518, 10.1109/58.808876 · DOI
  101. Chen, 2005, The Effective Electromechanical Coupling Coefficient of Piezoelectric Thin-Film Resonators, Appl. Phys. Lett., 86, 022904, 10.1063/1.1850615 · DOI
  102. Lonjon, 2016, Effectiveness of Virtual Reality Training in Orthopaedic Surgery, Arthrosc. J. Arthrosc. Relat. Surg., 32, 224, 10.1016/j.arthro.2015.07.023 · DOI
  103. Liu, Y.-H., Su, H.-Y., Lin, H.-C., Li, C.-Y., Wang, Y.-H., and Huang, C.-H. (2022). Investigation of Achieving Ultrasonic Haptic Feedback Using Piezoelectric Micromachined Ultrasonic Transducer. Electronics, 11. · DOI
  104. Herrera, B., Pop, F., Cassella, C., and Rinaldi, M. (2019, January 23–27). AlN PMUT-Based Ultrasonic Power Transfer Links for Implantable Electronics. Proceedings of the 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), Berlin, Germany. · DOI
  105. Dogheche, K., Cavallier, B., Delobelle, P., Hirsinger, L., Ballandras, S., Cattan, E., Rèmiens, D., Marzencki, M., Charlot, B., and Basrour, S. (2005, January 18–21). Piezoelectric Micro-Machined Ultrasonic Transducer (PMUT) for Energy Harvesting. Proceedings of the IEEE Ultrasonics Symposium, Rotterdam, The Netherlands.
  106. Cheng, 2019, Thin Film PZT-Based PMUT Arrays for Deterministic Particle Manipulation, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 66, 1606, 10.1109/TUFFC.2019.2926211 · DOI
  107. Sammoura, F., Smyth, K., and Kim, S.G. (2012, January 25–28). Working Equations of a Circular Multimorph Piezoelectric Micromachined Ultrasonic Transducer. Proceedings of the IECON 2012—38th Annual Conference on IEEE Industrial Electronics Society, Montreal, QC, Canada. · DOI
  108. Sammoura, 2013, Optimizing the Electrode Size of Circular Bimorph Plates with Different Boundary Conditions for Maximum Deflection of Piezoelectric Micromachined Ultrasonic Transducers, Ultrasonics, 53, 328, 10.1016/j.ultras.2012.06.015 · DOI

Cited by

Sorted by citations

See all 84

Metadata

Authors
Birjis, Y., Swaminathan, S., Nazemi, H., Raj, G. C. A., Munirathinam, P., Abu-Libdeh, A., & Emadi, A.
Affiliations
University of Windsor (CA)
Corresponding author
Emadi, Arezoo
Venue
Sensors
Publisher
MDPI AG
Published
2022-11-25
Volume
22
Issue
23
Pages
9151
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4310171752
Cited by
84
References
0
Citations by year
2026: 26 · 2025: 31 · 2024: 20 · 2023: 7
FWCI
1.53
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Scholarship at UWindsor (University of Windsor) (submittedVersion)
Funders
  • Windsor Cancer Centre Foundation
  • WE-SPARK Health Institute
  • Natural Sciences and Engineering Research Council of Canada (NSERC)
  • CMC Microsystems
  • University of Windsor Office
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Acoustic Wave Resonator Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
Keywords
piezoelectric micromachined ultrasonic transducers, microelectromechanical systems, microfabrication, parasitic capacitance, diagnostic imaging, range finding, energy harvesting, intra-body communication, underwater communication
MeSH terms
Equipment Design, Transducers, Ultrasonography, Ultrasonics, Micro-Electrical-Mechanical Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Piezoelectric Micromachined Ultrasonic Transducers (PMUTs): Performance Metrics, Advancements, and Applications. https://app.cochat.ai/papers/10.3390/s22239151
The paper
Birjis, Y., Swaminathan, S., Nazemi, H., Raj, G. C. A., Munirathinam, P., Abu-Libdeh, A., & Emadi, A. (2022). Piezoelectric Micromachined Ultrasonic Transducers (PMUTs): Performance Metrics, Advancements, and Applications. Sensors. https://doi.org/10.3390/s22239151