CoChat

Robustness of Physiological Synchrony in Wearable Electrodermal Activity and Heart Rate as a Measure of Attentional Engagement to Movie Clips

Open access
Stuldreher, Ivo V., van Erp, Jan B. F., Brouwer, Anne-Marie · 2023 · Sensors

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Individuals that pay attention to narrative stimuli show synchronized heart rate (HR) and electrodermal activity (EDA) responses. The degree to which this physiological synchrony occurs is related to attentional engagement. Factors that can influence attention, such as instructions, salience of the narrative stimulus and characteristics of the individual, affect physiological synchrony. The demonstrability of synchrony depends on the amount of data used in the analysis. We investigated how demonstrability of physiological synchrony varies with varying group size and stimulus duration. Thirty participants watched six 10 min movie clips while their HR and EDA were monitored using wearable sensors (Movisens EdaMove 4 and Wahoo Tickr, respectively). We calculated inter-subject correlations as a measure of synchrony. Group size and stimulus duration were varied by using data from subsets of the participants and movie clips in the analysis. We found that for HR, higher synchrony correlated significantly with the number of answers correct for questions about the movie, confirming that physiological synchrony is associated with attention. For both HR and EDA, with increasing amounts of data used, the percentage of participants with significant synchrony increased. Importantly, we found that it did not matter how the amount of data was increased. Increasing the group size or increasing the stimulus duration led to the same results. Initial comparisons with results from other studies suggest that our results do not only apply to our specific set of stimuli and participants. All in all, the current work can act as a guideline for future research, indicating the amount of data minimally needed for robust analysis of synchrony based on inter-subject correlations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s23063006

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Participant-to-group physiological synchrony for each participant’s HR (a) and EDA (b). In each window, each marker refers to a participant. Filled markers depict inter-subject correlations exceeding chance-level correlations based on 500 trials of circular shuffle (depicted by the grey distributions); open markers depict inter-subject correlations not exceeding chance level. x depicts missing data.
Figure 1 Participant-to-group physiological synchrony for each participant’s HR (a) and EDA (b). In each window, each marker refers to a participant. Filled markers depict inter-subject correlations exceeding chance-level correlations based on 500 trials of circular shuffle (depicted by the grey distributions); open markers depict inter-subject correlations not exceeding chance level. x depicts missing data.CC BY · PubMed Central
Figure 2 Percentage of participants with significant inter-subject correlations for HR (top; a,b) and EDA (bottom; c,d) as a function of stimulus duration (left; a,c) and participant group size (right; b,d), averaged over the six movie orders and 50 subsets of participant combinations. The color of the lines refers to the group size in the left plots and to the stimulus duration in the right plots, as do the numbers on the right side of some of the lines.
Figure 2 Percentage of participants with significant inter-subject correlations for HR (top; a,b) and EDA (bottom; c,d) as a function of stimulus duration (left; a,c) and participant group size (right; b,d), averaged over the six movie orders and 50 subsets of participant combinations. The color of the lines refers to the group size in the left plots and to the stimulus duration in the right plots, as do the numbers on the right side of some of the lines.CC BY · PubMed Central
Figure 3 Standard deviation across movies (left a,c) and subgroups (right; b,d) of the percentage of participants with significant inter-subject correlations for HR (top); (a,b) and EDA (bottom; c,d) as a function of stimulus duration (left; a,c) and participant group size (right; b,d). The color of the lines refers to the group size in the left plots and to the stimulus duration in the right plots.
Figure 3 Standard deviation across movies (left a,c) and subgroups (right; b,d) of the percentage of participants with significant inter-subject correlations for HR (top); (a,b) and EDA (bottom; c,d) as a function of stimulus duration (left; a,c) and participant group size (right; b,d). The color of the lines refers to the group size in the left plots and to the stimulus duration in the right plots.CC BY · PubMed Central
Figure 4 Fraction of participants with significant inter-subject correlations for HR (a) and EDA (b) as a function of the total minutes of data included in analysis, varied through varying stimulus duration and group size. For each datapoint, the stimulus duration is reflected by the marker size and the group size is reflected by the marker color.
Figure 4 Fraction of participants with significant inter-subject correlations for HR (a) and EDA (b) as a function of the total minutes of data included in analysis, varied through varying stimulus duration and group size. For each datapoint, the stimulus duration is reflected by the marker size and the group size is reflected by the marker color.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Borovac, A., Stuldreher, I.V., Thammasan, N., and Brouwer, A.M. (2021, January 13–15). Validation of Wearables for Electrodermal Activity (EdaMove) and Heart Rate (Wahoo Tickr). Proceedings of the 12th International Conference on Methods and Techniques in Behavioral Research and 6th Seminar on Behavioral Methods, Kraków, Poland.

Cited by

See all 20

Metadata

Authors
Stuldreher, I. V., van Erp, J. B. F., & Brouwer, A.-M.
Affiliations
  • Netherlands Organisation for Applied Scientific Research (NL)
  • Human Media Interaction, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, 7522 NB Enschede, The Netherlands
  • Radboud University Nijmegen (NL)
Corresponding author
Stuldreher, Ivo V.
Venue
Sensors
Publisher
MDPI AG
Published
2023-03-10
Volume
23
Issue
6
Pages
3006
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4324066780
Cited by
18
References
36
Citations by year
2026: 8 · 2025: 2 · 2024: 4 · 2023: 4
FWCI
3.54
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TNO Repository (submittedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Twente Research Information (submittedVersion, cc-by)
Funders
TNO’s Early Research Program Body-Brain Interaction
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
physiological synchrony, electrodermal activity, heart rate, attentional engagement, inter-subject correlation, wearable sensors, film clips, group size, stimulus duration, data robustness
MeSH terms
Wearable Electronic Devices, Galvanic Skin Response, Heart Rate, Humans, Motion Pictures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.