The DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Electrochemical Sensors for Clinic Analysis
Open accessAbstract
Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for clinic analysis. This review addresses the principles behind electrochemical sensor design and fabrication, and introduces recent progress in the application of electrochemical sensors to analysis of clinical chemicals such as blood gases, electrolytes, metabolites, DNA and antibodies, including basic and applied research. Miniaturized commercial electrochemical biosensors will form the basis of inexpensive and easy to use devices for acquiring chemical information to bring sophisticated analytical capabilities to the non-specialist and general public alike in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Metabolic Basis of Inherited Disease.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-503_7 · Cited by 7,786
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214 · cited 1×
“Recent developments of immunoassay and DNA sensors will also be introduced [2-8].”
BackgroundApplication of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Home blood glucose biosensors: a commercial perspective
Newman, J. D., & Turner, A. P. F. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.012 · Cited by 900
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 768
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Gazdik, Z., Zitka, O., Petrlova, J., Adam, V., Zehnalek, J., Horna, A., Reznicek, V., Beklova, M., & Kizek, R. (2008) · Sensors · doi:10.3390/s8117097 · Cited by 170
Metadata
- Authors
- Wang, Y., Xu, H., Zhang, J., & Li, G.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-03-27
- Volume
- 8
- Issue
- 4
- Pages
- 2043-2081
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2108803958
- Cited by
- 398
- References
- 109
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Sensors for Clinic Analysis. https://app.cochat.ai/papers/10.3390/s8042043
- The paper
- Wang, Y., Xu, H., Zhang, J., & Li, G. (2008). Electrochemical Sensors for Clinic Analysis. Sensors. https://doi.org/10.3390/s8042043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.