Determination of Hydrophilic UV Filters in Real Matrices Using New-Generation Bar Adsorptive Microextraction Devices
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
In the present contribution, new-generation bar adsorptive microextraction devices combined with microliquid desorption, followed by high-performance liquid chromatography–diode array detection (BAµE-µLD/HPLC–DAD) are proposed for the determination of two very polar ultraviolet (UV) filters (2-phenylbenzimidazole-5-sulfonic acid (PBS) and 5-benzoyl-4-hydroxy-2-methoxybenzenesulfonic acid (BZ4)) in aqueous media. Different sorbents were evaluated as BAµE coating phases, in which polystyrene–divinylbenzene polymer showed the best selectivity for the analysis of both UV filters, with average extraction efficiency of 61.8 ± 9.1% for PBS and 69.5 ± 4.8% for BZ4. The validated method showed great reproducibility for the analysis of PBS and BZ4 UV filters, providing suitable limits of detection (0.04 µg L−1 and 0.20 µg L−1), as well as good linear dynamic ranges (0.16–16.0 and 0.8–80.0 µg L−1), respectively. The proposed methodology was applied for monitoring the target analytes in several real matrices, including tap, sea, and estuarine waters, as well as wastewater samples. Despite some matrix effects being observed for some real samples, good selectivity and linearity were obtained. The present contribution showed an innovative analytical cycle that includes the use of disposable devices, which make BAµE much more user-friendly and suitable for the routine work, being a remarkable analytical alternative for trace analysis of priority compounds in real matrices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 9
Research works printed but not linked: 14
- Arthur, 1990, Solid phase microextraction with thermal desorption using fused silica optical fibers, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- Baltussen, 1999, Stir bar sorptive extraction (SBSE), a novel extraction technique for aqueous samples: Theory and principles, J. Microcolumn., 11, 737, 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO;2-4 · DOI · Paper page
- Neng, 2010, Adsorptive micro-extraction techniques-novel analytical tools for trace levels of polar solutes in aqueous media, J. Chromatogr. A, 1217, 7303, 10.1016/j.chroma.2010.09.048 · DOI
- Nogueira, 2012, Novel sorption-based methodologies for static microextraction analysis: A review on sbse and related techniques, Anal. Chim. Acta, 757, 1, 10.1016/j.aca.2012.10.033 · DOI
- Ide, 2018, New-generation bar adsorptive microextraction (BAμE) devices for a better eco-user-friendly analytical approach–Application for the determination of antidepressant pharmaceuticals in biological fluids, J. Pharm. Biomed. Anal., 153, 126, 10.1016/j.jpba.2018.02.001 · DOI
- Kameda, 2011, Occurrence and profiles of organic sun-blocking agents in surface waters and sediments in japanese rivers and lakes, Environ. Pollut., 159, 1570, 10.1016/j.envpol.2011.02.055 · DOI · Paper page
- Tsui, 2014, Occurrence, distribution and ecological risk assessment of multiple classes of UV filters in surface waters from different countries, Water Res., 67, 55, 10.1016/j.watres.2014.09.013 · DOI · Paper page
- Alberto, 2011, Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter determination in water samples, J. Chromatogr. A, 1218, 2467, 10.1016/j.chroma.2011.02.047 · DOI · Paper page
- Nguyen, 2011, Rapid and selective determination of UV filters in seawater by liquid chromatography-tandem mass spectrometry combined with stir bar sorptive extraction, Talanta, 85, 2375, 10.1016/j.talanta.2011.07.085 · DOI
- Zhang, 2012, Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of ultraviolet filters in environmental water samples, Anal. Chim. Acta, 750, 120, 10.1016/j.aca.2012.04.014 · DOI
- Vila, 2016, Determination of fourteen UV filters in bathing water by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry, Anal. Methods, 8, 7069, 10.1039/C6AY01787H · DOI
- Negreira, 2009, Solid-phase extraction followed by liquid chromatography-tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samples, Anal. Chim. Acta, 654, 162, 10.1016/j.aca.2009.09.033 · DOI
- Bratkovics, 2011, Determination of seven commonly used organic UV filters in fresh and saline waters by liquid chromatography-tandem mass spectrometry, Anal. Methods, 3, 2943, 10.1039/c1ay05390f · DOI · Paper page
- Chisvert, 2016, Stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticles-nylon 6 composite for the extraction of hydrophilic organic compounds in aqueous media, Anal. Chim. Acta, 926, 63, 10.1016/j.aca.2016.04.042 · DOI
Metadata
- Authors
- Ide, A. H., & Nogueira, J. M. F.
- Venue
- Separations
- Publisher
- MDPI AG
- Published
- 2019-09-25
- Volume
- 6
- Issue
- 4
- Pages
- 45
- ISSN
- 2297-8739
- Cited by
- 9
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Hydrophilic UV Filters in Real Matrices Using New-Generation Bar Adsorptive Microextraction Devices. https://app.cochat.ai/papers/10.3390/separations6040045
- The paper
- Ide, A. H., & Nogueira, J. M. F. (2019). Determination of Hydrophilic UV Filters in Real Matrices Using New-Generation Bar Adsorptive Microextraction Devices. Separations. https://doi.org/10.3390/separations6040045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.