CoChat

Effects of Ethanol on the Supercritical Carbon Dioxide Extraction of Cannabinoids from Near Equimolar (THC and CBD Balanced) Cannabis Flower

Open access
Qamar, Sadia, Torres, Yady, Parekh, Harendra, Falconer, James · 2021 · Separations

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

In this study, supercritical carbon dioxide (scCO2) extractions of cannabinoids were conducted at four different densities (231, 590, 818, and 911 kg/m3) using ethanol (5% w/v) as a co-solvent. The chemical profiles of these cannabinoids were analysed via reverse-phase high-performance liquid chromatography (RP-HPLC). It was determined that scCO2, at low density (231 kg/m3), produced an extract yield of 6.1% w/v. At high scCO2 density (~818 kg/m3), the yield was 16.1% w/v. More specifically, the amounts of tetrahydrocannabinol (THC) and cannabidiol (CBD) in the scCO2 extract at 818 kg/m3 were 10.8 and 15.6% w/v, respectively. It was also found that the use of 5% w/v ethanol increased scCO2 extract yields at both low and high densities (7.6% w/v and 18.2% w/v, respectively). Additionally, the use of co-solvent increased this yield further under both low- and high-density conditions, to 13.7 and 19.1% w/v, respectively. Interestingly, higher scCO2 density (911 kg/m3) with and without ethanol did not improve the scCO2 extract yield or the amount of cannabinoids. Although this study provides new insights into the correlation between scCO2 density and ethanol co-extraction of CBD and THC, more studies are needed to determine how different scCO2 densities and co-solvents influence the extraction of cannabinoids.

Overview

Integrity signals

Registry

Crossref · 10.3390/separations8090154

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. King, M., and Bott, T.R. (2012). Extraction of Natural Products Using Near-Critical Solvents, Springer Science & Business Media.
  2. Brunner, G. (2013). Gas Extraction: An Introduction to Fundamentals of Supercritical Fluids and the Application to Separation Processes, Springer Science & Business Media. [1st ed.].

Cited by

See all 27

Metadata

Authors
Qamar, S., Torres, Y., Parekh, H., & Falconer, J.
Affiliations
  • The University of Queensland (AU)
  • School of Pharmacy, Pharmacy Australia Centre of Excellence, The University of Queensland, Brisbane 4000, Australia
Corresponding author
  • Qamar, Sadia
  • Falconer, James
Venue
Separations
Publisher
MDPI AG
Published
2021-09-15
Volume
8
Issue
9
Pages
154
ISSN
2297-8739 (ISSN-L)
OpenAlex
W3201419180
Cited by
26
References
20
Citations by year
2026: 7 · 2025: 5 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 1
FWCI
1.06
Type
journal article
Language
en
Open access
Locations
  • Separations (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Australian Government
  • University of Queensland
Topics
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Phase Equilibria and Thermodynamics
  • Health Sciences › Medicine › Pharmacology (medical) › Cannabis and Cannabinoid Research
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
Keywords
supercritical CO2 extraction, ethanol co-solvent, cannabinoids, tetrahydrocannabinol, cannabidiol, cannabis flower, extraction yield, co-extraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.