A Comparison of the Energy Saving and Carbon Reduction Performance between Reinforced Concrete and Cross-Laminated Timber Structures in Residential Buildings in the Severe Cold Region of China
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper aims to investigate the energy saving and carbon reduction performance of cross-laminated timber residential buildings in the severe cold region of China through a computational simulation approach. The authors selected Harbin as the simulation environment, designed reference residential buildings with different storeys which were constructed using reinforced concrete (RC) and cross-laminated timber (CLT) systems, then simulated the energy performance using the commercial software IESTM and finally made comparisions between the RC and CLT buildings. The results show that the estimated energy consumption and carbon emissions for CLT buildings are 9.9% and 13.2% lower than those of RC buildings in view of life-cycle assessment. This indicates that the CLT construction system has good potential for energy saving when compared to RC in the severe cold region of China. The energy efficiency of residential buildings is closely related to the height for both RC and CLT buildings. In spite of the higher cost of materials for high-rise buildings, both RC and CLT tall residential buildings have better energy efficiency than low-rise and mid-rise buildings in the severe cold region of China.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross-Laminated Timber for Seismic Regions: Progress and Challenges for Research and Implementation
Pei, S., van de Lindt, J. W., Popovski, M., Berman, J. W., Dolan, J. D., Ricles, J., Sause, R., Blomgren, H., & Rammer, D. R. (2016) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001192 · Cited by 150 · cited 3×
“also indicated that the use of CLT as the construction material for a 10-storey building may result in a slightly lower cost than the concrete alternative (4%) [28].”
BackgroundInfluential
Cited by
Cross-laminated timber for building construction: a life-cycle-assessment overview
Younis, A., & Dodoo, A. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104482 · Cited by 175
Chen, C. X., Pierobon, F., & Ganguly, I. (2019) · Sustainability · doi:10.3390/su11051278 · Cited by 115
Dodoo, A., Nguyen, T., Dorn, M., Olsson, A., & Bader, T. K. (2022) · Wood Material Science & Engineering · doi:10.1080/17480272.2021.1974937 · Cited by 46
Metadata
- Authors
- Guo, H., Liu, Y., Meng, Y., Huang, H., Sun, C., & Shao, Y.
- Venue
- Sustainability
- Publisher
- MDPI AG
- Published
- 2017-08-12
- Volume
- 9
- Issue
- 8
- Pages
- 1426
- ISSN
- 2071-1050 (ISSN-L)
- OpenAlex
- W2745026209
- Cited by
- 112
- References
- 1
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of the Energy Saving and Carbon Reduction Performance between Reinforced Concrete and Cross-Laminated Timber Structures in Residential Buildings in the Severe Cold Region of China. https://app.cochat.ai/papers/10.3390/su9081426
- The paper
- Guo, H., Liu, Y., Meng, Y., Huang, H., Sun, C., & Shao, Y. (2017). A Comparison of the Energy Saving and Carbon Reduction Performance between Reinforced Concrete and Cross-Laminated Timber Structures in Residential Buildings in the Severe Cold Region of China. Sustainability. https://doi.org/10.3390/su9081426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.