Comparison of Pulse Rate Variability and Heart Rate Variability for Hypoglycemia Syndrome
Abstract
Summary: Background: Heart rate variability (HRV) is a signal obtained from RR intervals of electro -cardiography (ECG) signals to evaluate the balance between the sympathetic nervous system and the parasympathetic nervous system; not only HRV but also pulse rate va -riability (PRV) extracted from finger pulse plethysmography (PPG) can reflect irregularities that may occur in heart rate and control procedures. Objectives: The purpose of this study is to compare the HRV and PRV during hypogly -cemia in order to evaluate the features that computed from PRV that can be used in detection of hypoglycemia. Methods: To this end, PRV and HRV of 10 patients who required testing with insulininduced hypoglycemia (IIHT) in Clinics of Endocrinology and Metabolism Diseases of Bezm-i Alem University (Istanbul, Turkey), were obtained. The recordings were done at three stages: prior to IIHT, during the IIHT, and after the IIHT. We used Bland-Altman analysis for comparing the parameters and to evaluate the correlation between HRV and PRV if exists. Results: Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, the root-mean square of the difference of successive intervals, standard deviation of successive intervals and the ratio of the low-to-high frequency power. Conclusions: In conclusion, all the features computed from PRV and HRV have close agreement and correlation according to Bland-Altman analyses’ results and features computed from PRV can be used in detection of hypoglycemia.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Prior works developed approaches from at most 100 individuals and in most cases recorded less than a day of data.
“These works developed approaches from at most 100 individuals and in most cases, recorded less than a day of data.”
From Sleep and temperature data from wearable devices support noninvasive detection of diabetes mellitus in a large-scale, retrospective analysis (2026) · cites this paper as [20]
The citation lists haven’t been fetched yet
References 38 · Cited by 11
- Authors
- Çelik, G., Yıldırım, M., Ilhan, M., Karaman, Ö., Taşan, E., Kara, S., & Okkesim, Ş.
- Affiliations
- Fatih University (TR)
- Bezmiâlem Vakıf Üniversitesi (TR)
- Venue
- Methods of Information in Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2016
- Volume
- 55
- Issue
- 03
- Pages
- 250-257
- ISSN
- 0026-1270 (ISSN-L)
- 2511-705X
- OpenAlex
- W2330621213
- Cited by
- 11
- References
- 38
- Citations by year
- 2026: 1 · 2024: 1 · 2022: 3 · 2020: 2 · 2019: 4
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Methods of Information in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- pulse rate variability, heart rate variability, hypoglycemia, insulin-induced hypoglycemia, sympathovagal balance, hypoglycemia detection, RR interval
- MeSH terms
- Algorithms, Female, Heart Rate, Humans, Hypoglycemia, Insulin, Male, Middle Aged, Pulse, Signal Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review