The DOI matches its Crossref record.
Sensor-Driven Position-Adaptive Spinal Cord Stimulation for Chronic Pain
Open accessAbstract
Background: Variation in the intensity of neurostimulation due to body position is a practical problem for many patients implanted with spinal cord stimulation (SCS) systems because positional changes may result in overstimulation or understimulation that leads to frequent need for compensatory manual programming adjustments. Objectives: The purpose of this study was to assess the safety and effectiveness of a novel type of SCS therapy designed to automatically adapt stimulation amplitude in response to changes in a patient’s position or activity. The primary objective of the study was to demonstrate that automatic position-adaptive SCS benefited patients in terms of pain relief and/or convenience compared with neurostimulation adjusted with conventional manual programming. Secondary objectives included assessment of worsened pain relief with automatic adjustment; change in pain score; and the number of manual programming adjustments with position-adaptive neurostimulation compared with manual programming. Study Design: Prospective, multicenter, open-label, randomized crossover study. Setting: Ten interventional pain management centers in the US. Methods: Patients were enrolled a minimum of one week after a successful SCS screening trial. They were then implanted with the RestoreSensorTM neurostimulation device (Medtronic, Inc., Minneapolis, MN) that could be programmed to either automatic position-adaptive stimulation (AdaptiveStimTM) or manual adjustment of stimulation parameters. After implant, all devices were programmed to conventional manual adjustment for a 4-week postoperative period. The patients were then randomized to either conventional manual programming adjustment or position-adaptive stimulation with crossover to the opposite treatment arm occurring at 6 weeks after randomization. The patients were followed for another 6 weeks after crossover. This study was conducted under an FDA-approved Investigational Device Exemption (IDE) and approval of the responsible Institutional Review Boards (IRBs) of the study centers. Results: Seventy-nine patients were enrolled in the study. In an intent-to-treat analysis, 86.5% of patients achieved the primary objective of improved pain relief with no loss of convenience or improved convenience with no loss of pain relief using automatic position-adaptive stimulation compared with using conventional manual programming adjustment alone. This was statistically significantly greater than the predefined minimum success rate of 25%, P < 0.001 (exact one-sided 97.5% lower confidence limit was 76.5%). Only 2.8% of patients reported worsened pain relief during position-adaptive stimulation compared with manual programming. There was a statistically significant reduction in the mean numeric pain rating scale score compared with baseline scores in both treatment arms. Additionally, position-adaptive stimulation demonstrated a statistically significant 41% reduction in the daily average number of programming button presses for amplitude adjustment compared with manual programming (18.2 per day versus 30.7 per day, P = 0.002). Functional improvements reported with position-adaptive stimulation included: improved comfort during position changes (80.3%); improved activity (69%); and improved sleep (47.9%). Adverse events associated with uncomfortable sensations from stimulation did not differ significantly between treatment arms. The incidence of device-related serious adverse events was 3.9%. Limitations: Patients and physicians were not blinded to whether devices were programmed to automatic position-adaptive stimulation or manual adjustment. Responses to assessment questionnaires were based on patient recall. Conclusions: The study demonstrated that automatic position-adaptive stimulation is safe and effective in providing benefits in terms of patient-reported improved pain relief and convenience compared with using manual programming adjustment alone. Key words: spinal cord stimulation, neurostimulation, position sensing, physical activity accelerometer, neuromodulation, effectiveness, pain relief, position-adaptive stimulation, posture-adaptive stimulation, AdaptiveStim Clinical Trial: NCT01106404
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Kapural, L., Yu, C., Doust, M. W., Gliner, B. E., Vallejo, R., Sitzman, B. T., Amirdelfan, K., Morgan, D. M., Yearwood, T. L., Bundschu, R., et al. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001418 · Cited by 470
Mekhail, N., Levy, R. M., Deer, T. R., Kapural, L., Li, S., Amirdelfan, K., Hunter, C. W., Rosen, S. M., Costandi, S. J., Falowski, S. M., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30414-4 · Cited by 357
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Metadata
- Authors
- Schultz, D.
- Venue
- Pain Physician
- Published
- 2012-01-14
- Volume
- 1;15
- Issue
- 1;1
- Pages
- 1-12
- ISSN
- 1533-3159 (ISSN-L)
- 2150-1149
- OpenAlex
- W2340243459
- Cited by
- 179
- References
- 0
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.