CoChat

Solvent demulsification-dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with gas chromatography-mass spectrometry for simultaneous determination of organochlorine pesticides in aqueous samples

WANG, Yu, ZHU, Chenghua, ZOU, Xiaoli, HUANG, Lizhi, YAN, Dong · 2013 · Chinese Journal of Chromatography
Cited by 9

The DOI matches its Crossref record.

Abstract

A novel method for simultaneous determination of eight organochlorine pesticides in solidification of floating organic drop coupled with gas chromatography-mass spectrometry (GC-MS) was established. A mixture of extractant (n-hexadecane) and dispersive agent (acetone) at the ratio of 1/5 (v/v) was injected into aqueous sample to form an emulsion and an extraction process was accomplished. The demulsifier (750 microL acetone) was then injected to break up the emulsion. The two phases were separated quickly without centrifugation. After being solidified in an ice-bath, the upper layer (n-hexadecane) was transferred into an Eppendorf tube and analyzed by GC-MS after melted at room temperature. Factors affecting extraction efficiency such as the type and volume of extractant, dispersive agent and demulsifier, also ionic strength and pH value of extraction system were studied. Under the optimized conditions, the working curve of the proposed method provided a good linearity in the range of 0.025-2.00 microg/L (r = 0.999 5-0.999 9). The detection limits of the organochlorine pesticides calculated by Hubaux-Vos method were 0.012-0.024 microg/L and the relative standard deviations (RSDs) ranged from 3.15% to 4.53%. The enrichment factors (EF) were 96-101. When the method was applied to the determination of farmland water, the average spiked recoveries were 96.77%-102.93% with the relative standard deviations of 2.68%-4.86%. The proposed method is sensitive and fast. It also has the advantage of little organic solvent consumption so that it is friendly to environment and suitable for batch analysis of organochlorine pesticides in aqueous samples. Meanwhile, it provides technical and methodological support for achieving the automation of sample pretreatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3724/sp.j.1123.2013.06008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
WANG, Y., ZHU, C., ZOU, X., HUANG, L., & YAN, D.
Venue
Chinese Journal of Chromatography
Published
2013
Volume
31
Issue
11
Pages
1076
ISSN
1000-8713 (ISSN-L)
OpenAlex
W1537803550
Cited by
9
References
0
FWCI
0.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.