Cited by 406Tissue Engineering and Regenerative Medicine3D Printing in Biomedical ResearchElectrospun Nanofibers in Biomedical Applications

Decellularized Native and Engineered Arterial Scaffolds for Transplantation

Open access
Dahl, Shannon L. M., Koh, Jennifer, Prabhakar, Vikas, Niklason, Laura E.·2003·Cell Transplantation

Abstract

More than 570,000 coronary artery bypass grafts are implanted each year, creating an important demand for small-diameter vascular grafts. For patients who lack adequate internal mammary artery or saphenous vein, tissue-engineered arteries may prove useful. However, the time needed to tissue engineer arteries (7 weeks or more) is too long for many patients. Decellularized cadaveric human arteries are another possible source of vascular conduit, but limited availability and the potential for disease transmission limit their widespread use. In contrast, decellularized tissue-engineered arteries could serve as grafts for immediate implantation, as scaffolds onto which patients' cells could be seeded, or as carriers for genetically engineered cells to aid cell transplantation. The goal of this study was to quantify the effects of decellularization on vascular matrix and mechanical properties. Specifically, we compared cellular elimination, extracellular matrix retention, and mechanical characteristics of porcine carotid arteries before and after treatment with three decellularization methods. In addition, for the first time, tissue-engineered arteries were decellularized. Decellularized native arteries were also used as a scaffold onto which vascular cells were seeded. These studies identified a decellularization method for native and engineered arteries that maximized cellular elimination, without greatly compromising mechanical integrity. We showed that engineered tissues could be decellularized, and demonstrated the feasibility of reseeding decellularized vessels with vascular cells.

Integrity signals

Registry

Crossref · 10.3727/000000003108747136

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Although hypertonic solutions are efficient in removing proteins and hypotonic solutions are efficient in removing nuclei and DNA, they may not completely eliminate cellular residues and may require additional treatment to facilitate removal of cellular debris.

    “Although hypertonic solutions are efficient in removing proteins and hypotonic solutions are efficient in removing nuclei and DNA, they may not completely eliminate cellular residues and may require additional treatment to facilitate the removal of cellular debris [117,119,120].”
  • Immersion and agitation constitute a relatively straightforward decellularization method commonly used for thin tissues and smaller organs lacking vascular access.

    “Immersion and agitation constitute a relatively straightforward decellularization method commonly used for thin tissues and smaller organs lacking vascular access, such as the esophagus, small intestine submucosa, urinary bladder, blood vessels, trachea, skin, cornea, and nerve [117,119,120,126,152,[163], [164], [165], [166], [167]].”

The citation lists haven’t been fetched yet

References 21 · Cited by 406

Authors
Dahl, S. L. M., Koh, J., Prabhakar, V., & Niklason, L. E.
Affiliations
  • Departments of Biomedical Engineering, Durham, NC 27708
  • University of California San Diego (US)
  • Massachusetts Institute of Technology (US)
  • Duke University (US)
Corresponding author
Niklason, Laura E.
Venue
Cell Transplantation
Published
2003-09
Volume
12
Issue
6
Pages
659-666
ISSN
  • 0963-6897 (ISSN-L)
  • 1555-3892
OpenAlex
W2103720021
Cited by
406
References
21
Citations by year
2026: 4 · 2025: 10 · 2024: 19 · 2023: 24 · 2022: 18 · 2021: 24 · 2020: 31 · 2019: 29 · 2018: 10 · 2017: 23 · 2016: 16 · 2015: 29 · 2014: 34 · 2013: 28 · 2012: 18
FWCI
4.49
Type
journal article
Language
en
Open access
Locations
  • Cell Transplantation (publishedVersion)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Heart, Lung, and Blood Institute (R01HL063766)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
Keywords
decellularization, coronary artery bypass grafting, small-diameter vascular grafts, mechanical properties, porcine carotid artery, decellularization methods, cell seeding
MeSH terms
Animals, Coronary Artery Bypass, Artificial Organs, Biocompatible Materials, Carotid Arteries, Cattle, Cell Separation, Collagen, DNA, Extracellular Matrix, Humans, Muscle, Smooth, Vascular, Stress, Mechanical, Transplantation, Heterologous, Tissue Transplantation, Weight-Bearing, Tissue Engineering, Sus scrofa

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review