Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Utility of serum CA19-9 in diagnosis of cholangiocarcinoma: In comparison with CEA

Open access
Qin, Xing-Lei, Wang, Zuo-Ren, Shi, Jing-Sen, Lu, Min, Wang, Lin, He, Quan-Ru · 2004 · World Journal of Gastroenterology

Abstract

AIM: The diagnosis of cholangiocarcinoma is often difficult, making management approaches problematic. A reliable serum marker for cholangiocarcinoma would be a useful diagnostic test. The aims of our study were to evaluate the usefulness of a serum CA19-9 determination in the diagnosis of cholangiocarcinoma. METHODS: We prospectively measured serum CA19-9 and CEA concentrations in patients with cholangiocarcinoma (n=35), benign biliary diseases (n=92), and healthy individuals (n=15). Serum CA19-9 and CEA concentrations were measured by an immunoradiometric assay without knowledge of the clinical diagnosis. RESULTS: The sensitivity of a CA19-9 value >37 KU/L(-1) and a CEA value >22 microg/L(-1) in diagnosing cholangiocarcinoma were 77.14% and 68.57%, respectively. When compared with the benign biliary diseases group, the true negative rates of serum CA19-9 and CEA were 84.78% and 81.52%, respectively. The false positive rates of serum CA19-9 and CEA were 15.22% and 18.48%, whereas the accuracy of serum CA19-9 and CEA were 82.68% and 77.95%, respectively. Serum CA19-9 and CEA concentrations were significantly elevated (P<0.001 and P<0.05) in patients with cholangiocarcinoma (290.31+/-5.34 KU/L(-1) and 36.46+/-18.03 microg/L(-1)) compared with patients with benign biliary diseases (13.38+/-2.59 KU/L(-1) and 13.84+/-3.85 microg/L(-1)) and healthy individuals (12.78+/-3.69 KU/L(-1) and 11.48+/-3.37 microg/L(-1)). In 15 patients undergoing curative resection of cholangiocarcinoma, the mean serum CA19-9 concentration was decreased from a preoperative level of 286.41+/-4.36 KU/L(-1) to a postoperative level of 62.01+/-17.43 KU/L(-1) (P<0.001), and the mean serum CEA concentration from 39.41+/-24.35 microg/L(-1) to 28.69+/-11.03 microg/L(-1) (P<0.05). In patients with cholangiocarcinoma, however, no correlation was found between serum CEA and CA19-9 concentrations (r=0.036). CONCLUSION: These data suggest that the serum CA19-9 determination is a useful addition to the available tests for the differential diagnosis of cholangiocarcinoma. Serum CA19-9 is an effective tumor marker in diagnosing cholangiocarcinoma, deciding whether the tumor has been radically resected and monitoring effect of treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3748/wjg.v10.i3.427

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 182

Metadata

Authors
Qin, X.-L., Wang, Z.-R., Shi, J.-S., Lu, M., Wang, L., & He, Q.-R.
Venue
World Journal of Gastroenterology
Published
2004
Volume
10
Issue
3
Pages
427
ISSN
1007-9327 (ISSN-L)
OpenAlex
W2135972280
Cited by
182
References
2
FWCI
4.85
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Utility of serum CA19-9 in diagnosis of cholangiocarcinoma: In comparison with CEA. https://app.cochat.ai/papers/10.3748/wjg.v10.i3.427
The paper
Qin, X.-L., Wang, Z.-R., Shi, J.-S., Lu, M., Wang, L., & He, Q.-R. (2004). Utility of serum CA19-9 in diagnosis of cholangiocarcinoma: In comparison with CEA. World Journal of Gastroenterology. https://doi.org/10.3748/wjg.v10.i3.427

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.