The DOI matches its Crossref record.
Contrast-enhanced endoscopic ultrasound in discrimination between focal pancreatitis and pancreatic cancer
Open accessAbstract
AIM: To evaluate the contrast-enhanced endosonography as a method of differentiating inflammation from pancreatic carcinoma based on perfusion characteristics of microvessels. METHODS: In 86 patients with suspected chronic pancreatitis (age: 62+/-12 years; sex: f/m 38/48), pancreatic lesions were examined by conventional endoscopic B-mode, power Doppler ultrasound and contrast-enhanced power mode (Hitachi EUB 525, SonoVue, 2.4 mL, Bracco) using the following criteria for malignant lesions: no detectable vascularisation using conventional power Doppler scanning, irregular appearance of arterial vessels over a short distance using SonoVue contrast-enhanced technique and no detectable venous vessels inside the lesion. A malignant lesion was assumed if all criteria were detectable [gold standard endoscopic ultrasound (EUS)-guided fine needle aspiration cytology, operation]. The criteria of chronic pancreatitis without neoplasia were defined as no detectable vascularisation before injection of SonoVue, regular appearance of vessels over a distance of at least 20 mm after injection of SonoVue and detection of arterial and venous vessels. RESULTS: The sensitivity and specificity of conventional EUS were 73.2% and 83.3% respectively for pancreatic cancer. The sensitivity of contrast-enhanced EUS increased to 91.1% in 51 of 56 patients with malignant pancreatic lesion and the specificity increased to 93.3% in 28 of 30 patients with chronic inflammatory pancreatic disease. CONCLUSION: Contrast-enhanced endoscopic ultrasound improves the differentiation between chronic pancreatitis and pancreatic carcinoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Piscaglia, F., Nolsøe, C., Dietrich, C., Cosgrove, D., Gilja, O., Bachmann Nielsen, M., Albrecht, T., Barozzi, L., Bertolotto, M., Catalano, O., et al. (2011) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0031-1281676 · Cited by 1,082
Self-citationClaudon, M., Cosgrove, D., Albrecht, T., Bolondi, L., Bosio, M., Calliada, F., Correas, J.-M., Darge, K., Dietrich, C., D’Onofrio, M., et al. (2008) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2007-963785 · Cited by 764
Self-citationKitano, M., Kudo, M., Yamao, K., Takagi, T., Sakamoto, H., Komaki, T., Kamata, K., Imai, H., Chiba, Y., Okada, M., et al. (2012) · American Journal of Gastroenterology · doi:10.1038/ajg.2011.354 · Cited by 340
Săftoiu, A., Vilmann, P., Gorunescu, F., Gheonea, D. I., Gorunescu, M., Ciurea, T., Popescu, G. L., Iordache, A., Hassan, H., & Iordache, S. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.04.031 · Cited by 260
Săftoiu, A., Vilmann, P., Dietrich, C. F., Iglesias-Garcia, J., Hocke, M., Seicean, A., Ignee, A., Hassan, H., Streba, C. T., Ioncică, A. M., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.11.040 · Cited by 150
Self-citation
Metadata
- Authors
- Hocke, M., Schulze, E., Gottschalk, P., Topalidis, T., & Dietrich, C. F.
- Venue
- World Journal of Gastroenterology
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2006
- Volume
- 12
- Issue
- 2
- Pages
- 246
- ISSN
- 1007-9327 (ISSN-L)
- OpenAlex
- W2167452327
- Cited by
- 209
- References
- 0
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast-enhanced endoscopic ultrasound in discrimination between focal pancreatitis and pancreatic cancer. https://app.cochat.ai/papers/10.3748/wjg.v12.i2.246
- The paper
- Hocke, M., Schulze, E., Gottschalk, P., Topalidis, T., & Dietrich, C. F. (2006). Contrast-enhanced endoscopic ultrasound in discrimination between focal pancreatitis and pancreatic cancer. World Journal of Gastroenterology. https://doi.org/10.3748/wjg.v12.i2.246
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.