The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Bowel preparation quality scales for colonoscopy
Open accessAbstract
Colorectal cancer (CRC) is the third most common cancer and second leading cause of cancer-related death in the United States. Colonoscopy is widely preferred for CRC screening and is the most commonly used method in the United States. Adequate bowel preparation is essential for successful colonoscopy CRC screening. However, up to one-quarter of colonoscopies are associated with inadequate bowel preparation, which may result in reduced polyp and adenoma detection rates, unsuccessful screens, and an increased likelihood of repeat procedure. In addition, standardized criteria and assessment scales for bowel preparation quality are lacking. While several bowel preparation quality scales are referred to in the literature, these differ greatly in grading methodology and categorization criteria. Published reliability and validity data are available for five bowel preparation quality assessment scales, which vary in several key attributes. However, clinicians and researchers continue to use a variety of bowel preparation quality measures, including nonvalidated scales, leading to potential confusion and difficulty when comparing quality results among clinicians and across clinical trials. Optimal clinical criteria for bowel preparation quality remain controversial. The use of validated bowel preparation quality scales with stringent but simple scoring criteria would help clarify clinical trial data as well as the performance of colonoscopy in clinical practice related to quality measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability and Validity Assessment
Carmines, E., & Zeller, R. (1979) · doi:10.4135/9781412985642 · Cited by 5,884
Screening for Colorectal Cancer: US Preventive Services Task Force Recommendation Statement
US Preventive Services Task Force, Bibbins-Domingo, K., Grossman, D. C., Curry, S. J., Davidson, K. W., Epling, J. W., García, F. A. R., Gillman, M. W., Harper, D. M., Kemper, A. R., et al. (2016) · JAMA · doi:10.1001/jama.2016.5989 · Cited by 2,509
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Metadata
- Authors
- Kastenberg, D., Bertiger, G., & Brogadir, S.
- Venue
- World Journal of Gastroenterology
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2018-07-14
- Volume
- 24
- Issue
- 26
- Pages
- 2833-2843
- ISSN
- 1007-9327 (ISSN-L)
- OpenAlex
- W2851918126
- Cited by
- 240
- References
- 3
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bowel preparation quality scales for colonoscopy. https://app.cochat.ai/papers/10.3748/wjg.v24.i26.2833
- The paper
- Kastenberg, D., Bertiger, G., & Brogadir, S. (2018). Bowel preparation quality scales for colonoscopy. World Journal of Gastroenterology. https://doi.org/10.3748/wjg.v24.i26.2833
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.