CoChat

Efficacy of the Antioxidant N-acetylcysteine (NAC) in Protecting Ears Exposed to Loud Music

Kramer, Steven, Dreisbach, Laura, Lockwood, Jill, Baldwin, Kristy, Kopke, Richard, Scranton, Shawn, O'Leary, Michael · 2006 · Journal of the American Academy of Audiology
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Antioxidants have been reported to be effective in reducing acoustic trauma in animal models but have not been studied in humans. In this study, the antioxidant N-acetylcysteine (NAC) was evaluated to determine if it would reduce temporary changes in auditory function as a result of exposure to loud music in humans. Pure-tone thresholds and distortion product otoacoustic emissions (DPOAEs) were collected in 31 normal-hearing participants, using a randomized, double-blind, placebo-controlled design, before and after two hours of live music in a nightclub. Using repeated measures analysis of variance, no statistically significant differences were found between participants who received NAC versus a placebo for any of the outcome measures. Across all subjects, the largest pure-tone threshold shift occurred at 4 kHz. DPOAE measures were characterized by reductions in amplitude and a trend for shorter group delay values. When the 3 and 4 kHz data were examined by imposing specific criteria of greater than 2 dB DPOAE amplitude reductions and 10 dB or greater pure-tone threshold shifts, DPOAE reductions occurred more often at 3 kHz, and pure-tone shifts occurred more often at 4 kHz. Se ha reportado que los antioxidantes son efectivos en reducir el trauma acústico en modelos animales, pero ésto no han sido estudiados en humanos. En este estudio, se evaluó el antioxidante N-acetilcisteína (NAC) para determinar si podría reducir los cambios temporales en la función auditiva, como consecuencia de la exposición en humanos a música de alta intensidad. Se registraron umbrales para tonos puros y emisiones otoacústicas por productos de distorsión (DPOAE) en 31 participantes con audición normal, utilizando un diseño aleatorio, doble ciego, controlado por placebo, dos horas antes y después de la exposición a música en vivo en un club nocturno. Usando análisis de variancia de medidas repetidas, no se encontraron diferencias estadísticamente significativas entre los participantes que recibieron NAC versus placebo, en ninguna de las medidas de resultado. En todos los sujetos, el cambio de umbral tonal más grande ocurrió a 4 kHz. Las DPOAE mostraron reducciones en la amplitud y una tendencia a valores más cortos en retraso grupal. Cuando se examinaron las frecuencias de 3 y 4 KHz, imponiendo criterios específicos de reducción de más de 2 dB en la amplitud de las DPOAE y 10 dB o más en el cambio del umbral tonal, la reducción en las DPOAE ocurrió más a menudo en 3 kHz y los cambios tonales ocurrieron más a menudo en 4 kHz.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3766/jaaa.17.4.5

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 97

Metadata

Authors
Kramer, S., Dreisbach, L., Lockwood, J., Baldwin, K., Kopke, R., Scranton, S., & O'Leary, M.
Venue
Journal of the American Academy of Audiology
Published
2006-04-01
Volume
17
Issue
4
Pages
265-278
ISSN
1050-0545
Cited by
97
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.