The DOI matches its Crossref record.
Estimation of Signal-to-Noise Ratios in Realistic Sound Scenarios
Abstract
Background:Both in the design of hearing-device features, such as noise reduction, and in the evaluation measurements of such features, there is a need for more information about the sound scenarios hearing-device users encounter. The limitations of adaptive speech tests as outcome measures in the evaluation of hearing-device features have been discussed. The obvious alternative to adaptive speech testing is to test at a fixed signal-to-noise ratio (SNR). However, the question is which SNRs should be used if the test reflects real-life situations.Purpose:The purpose of this study was to estimate SNRs in realistic sound environments encountered by hearing aid users.Research Design:Research design was a descriptive study where recorded sound files were statistically analyzed.Study Sample:A total of 20 experienced, bilaterally fitted hearing aid users, all satisfied with their current hearing aids, made recordings for 3‐4 days. The informants were instructed to record different situations in daily life and were told that all situations were of equal importance. The informants ranged in age from 18‐81 yr old, and they had various occupations and varying hearing-loss configurations.Data Collection and Analysis:The total duration of the recorded material for each informant was, on average, 84 min; the number of recordings was, on average, 17 per informant. The sound files were categorized based on the type of background noise and were analyzed with use of a manual noise estimation procedure. Segments of speech with noise present were cut out from the original recordings. Corresponding noise-only segments were also extracted. On the basis of power calculations for these two types of recorded segments, the SNR was estimated. Frequency-specific and overall SNRs, calculated both based on unweighted and A-weighted speech and noise levels, were derived. An estimation uncertainty measure was also developed.Results:The range of SNRs found in the material was large. The most striking finding was that there were very few recorded situations where the SNR was negative or even close to 0 dB. For speech-in-babble noise, the average SNR was approximately 5 dB. The estimation uncertainty was generally low but became higher in highly fluctuating noises and at very low SNRs.Conclusions:The estimated SNRs were higher than previously reported. The results can be used in the design and evaluation of hearing-device features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Using speech recall in hearing aid fitting and outcome evaluation under ecological test conditions.
Lunner, T., Rudner, M., Rosenbom, T., Ågren, J., & Ng, E. H. N. (2016) · Ear & Hearing · doi:10.1097/aud.0000000000000294 · Cited by 61
Cognitive spare capacity as an index of listening effort
Rudner, M. (2016) · Ear & Hearing · doi:10.1097/aud.0000000000000302 · Cited by 52
“In everyday communication, we can often hear the words that are being said (Smeds et al. 2015) even though external factors such as background noise or the demands of multitasking and internal factors such as cognitive load may combine to make listening seem effortful (Rudner & Lunner 2013, 2014)…”
BackgroundChristensen, J. H., Whiston, H., Lough, M., Gil-Carvajal, J. C., Rumley, J., & Saunders, G. H. (2024) · American Journal of Audiology · doi:10.1044/2023_aja-23-00149 · Cited by 19
Metadata
- Authors
- Smeds, K., Wolters, F., & Rung, M.
- Venue
- Journal of the American Academy of Audiology
- Publisher
- American Academy of Audiology
- Published
- 2015-02-01
- Volume
- 26
- Issue
- 2
- Pages
- 183-196
- ISSN
- 1050-0545 (ISSN-L)
- OpenAlex
- W2312966647
- Cited by
- 278
- References
- 0
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.