The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Linearization of the Bradford Protein Assay
Open accessAbstract
Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Zor, T., & Selinger, Z. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0171 · Cited by 1,038
Self-citationMechanism of dye response and interference in the Bradford protein assay
Compton, S. J., & Jones, C. G. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90190-3 · Cited by 640
The Binding Interaction of Coomassie Blue with Proteins
Congdon, R. W., Muth, G. W., & Splittgerber, A. G. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1439 · Cited by 324
A Spectral Study of the Charge Forms of Coomassie Blue G
Chial, H. J., Thompson, H. B., & Splittgerber, A. G. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1117 · Cited by 76
A Comparison of the Binding of Coomassie Brilliant Blue to Proteins at Low and Neutral pH
Chial, H. J., & Splittgerber, A. G. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1433 · Cited by 59
Cited by
Paukkonen, H., Kunnari, M., Laurén, P., Hakkarainen, T., Auvinen, V.-V., Oksanen, T., Koivuniemi, R., Yliperttula, M., & Laaksonen, T. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.09.002 · Cited by 109
Gut microbiome catabolites as novel modulators of muscle cell glucose metabolism
Houghton, M. J., Kerimi, A., Mouly, V., Tumova, S., & Williamson, G. (2019) · The FASEB Journal · doi:10.1096/fj.201801209r · Cited by 92
Zirpel, B., Stehle, F., & Kayser, O. (2015) · Biotechnology Letters · doi:10.1007/s10529-015-1853-x · Cited by 83
West, J. K., Franz, J. L., Hein, S. M., Leverentz-Culp, H. R., Mauser, J. F., Ruff, E. F., & Zemke, J. M. (2023) · Journal of Chemical Education · doi:10.1021/acs.jchemed.3c00581 · Cited by 79
Qiu, D., Pei, J. V., Rosling, J. E. O., Thathy, V., Li, D., Xue, Y., Tanner, J. D., Penington, J. S., Aw, Y. T. V., Aw, J. Y. H., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33403-9 · Cited by 70
Metadata
- Authors
- Ernst, O., & Zor, T.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2010-04-12
- Issue
- 38
- ISSN
- 1940-087X (ISSN-L)
- DOI
- 10.3791/1918
- OpenAlex
- W2049210214
- Cited by
- 287
- References
- 6
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.