CoChat

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy

Reiberger, Thomas, Schwabl, Philipp, Trauner, Michael, Peck-Radosavljevic, Markus, Mandorfer, Mattias · 2020 · Journal of Visualized Experiments
Cited by 113

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Here we provide a detailed protocol describing the clinical procedure of hepatic venous pressure gradient (HVPG) measurement in patients with advanced chronic liver disease followed by an instruction for transjugular biopsy. Under local anesthesia and ultrasound guidance, a catheter introducer sheath is placed in the right internal jugular vein. Using fluoroscopic guidance, a balloon catheter is advanced into the inferior vena cava (IVC) and inserted into a large hepatic vein. Correct and sufficient wedge position of the catheter is ensured by injecting contrast media while the balloon is blocking the outflow of the cannulated hepatic vein. After calibrating the external pressure transducer, continuous pressure recordings are obtained with triplicate recordings of the wedged hepatic venous pressure (WHVP) and free hepatic venous pressure (FHVP). The difference between FHVP and WHVP is referred to as HVPG, with values ≥10 mm Hg indicating clinically significant portal hypertension (CSPH). Before removing the catheter, pressure readings obtained in the IVC at the same level, as well as the right atrial pressure are recorded. Finally, a transjugular liver biopsy can be obtained via the same vascular route. Different systems are available; however, core biopsy needles are preferred over aspiration needles, especially for cirrhotic livers. Again, under fluoroscopic guidance a biopsy needle introducer sheath is advanced into an hepatic vein. Next, the transjugular biopsy needle is gently advanced through the introducer sheath: (i) in case of aspiration biopsy, the needle is advanced into the liver parenchyma under aspiration and then removed quickly, or (ii) in case of a core biopsy, the cutting-mechanism is triggered inside the parenchyma. Several separate passages can be safely performed to obtain sufficient liver specimens via transjugular biopsy. In experienced hands, the combination of these procedures takes about 30-45 min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3791/58819

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Reiberger, T., Schwabl, P., Trauner, M., Peck-Radosavljevic, M., & Mandorfer, M.
Venue
Journal of Visualized Experiments
Published
2020-06-18
Issue
160
ISSN
1940-087X (ISSN-L)
OpenAlex
W3036992505
Cited by
113
References
3
FWCI
8.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.