CoChat

Investigating the Vulnerabilities of Structures to Ignition From a Firebrand Attack

Open access
Manzello, S., Shields, J., Hayashi, Y., Nii, Daisaku · 2008 · Fire Safety Science
Cited by 36

The DOI matches its Crossref record.

Abstract

A unique experimental apparatus, known as the Firebrand Generator, was used to generate a controlled and repeatable size and mass distribution of glowing firebrands.The size and mass distribution of firebrands produced from the generator was selected to be representative of firebrands produced from burning vegetation.The vulnerability of roofing materials to firebrand attack was ascertained using fluxes of firebrands produced using this device.The experiments were performed at the Fire Research Wind Tunnel Facility (FRWTF) at the Building Research Institute (BRI) in Tsukuba, Japan.A custom mounting assembly was constructed to support full scale sections of common roofing materials inside the FRWTF.The sections constructed for testing included full roofing assemblies (base layer, tar paper, and shingles) as well as only the base layer material, such as oriented strand board (OSB).The custom mounting assembly allowed for the construction of flat roofs as well as the construction of angled roofs (valleys).Results of this study are presented and discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3801/iafss.fss.9-143

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Manzello, S., Shields, J., Hayashi, Y., & Nii, D.
Venue
Fire Safety Science
Published
2008
Volume
9
Pages
143-154
ISSN
1817-4299 (ISSN-L)
OpenAlex
W1975007986
Cited by
36
References
0
FWCI
10.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.