Influence of outside temperature on the operation of the adsorption chiller
Open accessAbstract
Adsorption refrigeration systems are characterized by a lower coefficient of performance than the compressor type device or even absorption, but can utilize waste heat at lower temperature. The aim of the study was to determine which external parameter has the greatest impact on the efficiency of the adsorption device. As a result of experimental studies there was found that this is not the temperature of the feed but particularly the temperature of external air. For this reason, it is recommended that the adsorption device should cooperate with evaporative spray coolers, instead of with popular dry coolers. This solution will increase annual efficiency of adsorption unit approx. by 25% and significantly reduce the costs of cold generation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Outdoor air temperature plays an important role in the efficiency of absorption refrigeration.
“Grzebielec et al. [206] confirmed that the outdoor air temperature plays an important role in the efficiency of absorption refrigeration.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [206]
Desiccant cooling technology could be categorized in TRL 9 according to the Technology Readiness Assessment Guide issued by the U.S. Department of Energy.
“Desiccant cooling technology could be categorized in TRL 9 according to the Technology Readiness Assessment Guide issued by the U.S. Department of Energy [207].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [207]
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180 · see citing works
- Authors
- Grzebielec, A., Laskowski, R., & Ruciński, A.
- Affiliations
- Warsaw University of Technology (PL)
- Venue
- International Conference “Environmental Engineering”
- Published
- 2017-01-01
- Pages
- 1-6
- ISSN
- 2029-7092 (ISSN-L)
- OpenAlex
- W2759165525
- Cited by
- 2
- References
- 0
- Citations by year
- 2023: 1 · 2021: 1
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Environmental engineering (publishedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Carbon Dioxide Capture Technologies
- Keywords
- adsorption chiller, adsorption refrigeration, ambient temperature, coefficient of performance, dry coolers, waste heat recovery
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review