PIN TRACT INFECTIONS: SILVER VS UNCOATED PINS
The DOI matches its Crossref record.
Abstract
To test the hypothesis that coating external fixation pins with a silver-containing compound (Spi-Argent, Spire Corp, Bedford, Mass) will reduce bacterial colonization and/ or pin tract infection, 36 silver-coated and 12 conventional stainless steel pins were placed in the iliac crest of six sheep and inoculated with Staphylococcus aureus. After 2 ½ weeks the pin sites were examined for motion and inflammation, and the pin tips were quantitatively cultured and examined with scanning electron microscopy (SEM). We found that 84% of the uncoated pins were infected, while 62% of the silver-coated pins were infected. Silver-coated pins were less frequently infected than uncoated pins (confidence interval [CI] >85%). Also, silver-coated pins were loose less frequently than uncoated pins. Pin motion was closely correlated with infection: 28 of 32 infected pins (88%) had motion, while only 9 of 16 uninfected pins (56%) had motion (CI >80%). SEM study of the pin tips showed a decreased level of glycocalyx-protected colonization on the surface of the silver-coated pins. Clinically, these results suggest that silver-coated pins will result in less infection and motion at the pin site, the most significant problems in external fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Silver coated materials for external fixation devices: in vitro biocompatibility and genotoxicity
Bosetti, M., Massè, A., Tobin, E., & Cannas, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00198-3 · Cited by 557
Gosheger, G., Hardes, J., Ahrens, H., Streitburger, A., Buerger, H., Erren, M., Gunsel, A., Kemper, F. H., Winkelmann, W., & von Eiff, C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.008 · Cited by 441
Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings
Zhang, B., Myers, D., Wallace, G., Brandt, M., & Choong, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711878 · Cited by 394
Hardes, J., von Eiff, C., Streitbuerger, A., Balke, M., Budny, T., Henrichs, M. P., Hauschild, G., & Ahrens, H. (2010) · Journal of Surgical Oncology · doi:10.1002/jso.21498 · Cited by 337
Studies of photokilling of bacteria using titanium dioxide nanoparticles
Tsuang, Y., Sun, J., Huang, Y., Lu, C., Chang, W. H., & Wang, C. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00530.x · Cited by 247
Pin Tract Infection With Contemporary External Fixation: How Much of a Problem?
Parameswaran, A. D., Roberts, C. S., Seligson, D., & Voor, M. (2003) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200308000-00005 · Cited by 231
“Other factors that are important in pin tract problems include motion at the pin tract site and tissue necrosis.(4,10) Collinge et al(4) noted a close relationship between the motion of loose pins and infection.”
BackgroundSelf-citationBi, Y., Seabold, J. M., Kaar, S. G., Ragab, A. A., Goldberg, V. M., Anderson, J. M., & Greenfield, E. M. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.11.2082 · Cited by 227
Use of Silver in the Prevention and Treatment of Infections: Silver Review
Politano, A. D., Campbell, K. T., Rosenberger, L. H., & Sawyer, R. G. (2013) · Surgical Infections · doi:10.1089/sur.2011.097 · Cited by 204
“Early studies of external fixation pins demonstrated decreased bacterial presence on the intra-corporeal tips of silver-coated pins than on stainless steel pins, as well as less motion with silver pins in animal models [136].”
Prevention of pin tract infection with titanium‐copper alloys
Shirai, T., Tsuchiya, H., Shimizu, T., Ohtani, K., Zen, Y., & Tomita, K. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31412 · Cited by 199
“In particular, many silver-coated medical materials have been reported, such as cardiac and urinary catheters, heart valves, dialysis units, and orthopedic devices.(26-31) However, silver has been found to have toxic effects towards human cells.”
BackgroundWafa, H., Grimer, R. J., Reddy, K., Jeys, L., Abudu, A., Carter, S. R., & Tillman, R. M. (2015) · The Bone & Joint Journal · doi:10.1302/0301-620x.97b2.34554 · Cited by 196
Anti-Infective Efficacy of Silver-Coated Medical Prostheses
Darouiche, R. O. (1999) · Clinical Infectious Diseases · doi:10.1086/313561 · Cited by 195
“84%) [52].”
Silver nanoparticles and their orthopaedic applications
Brennan, S. A., Ní Fhoghlú, C., Devitt, B. M., O’Mahony, F. J., Brabazon, D., & Walsh, A. (2015) · The Bone & Joint Journal · doi:10.1302/0301-620x.97b5.33336 · Cited by 187
“The authors postulated that bacterial adherence to the surface of the silver-coated pins was prevented by inhibition of the formation of a bacterial glycocalyx membrane on the surface of the pin, rather than by local leaching of silver ions.(36) Coester et al(37) performed a prospective randomised study in patients to…”
Background
Metadata
- Authors
- Collinge, C. A., Goll, G., Seligson, D., & Easley, K. J.
- Venue
- Orthopedics
- Publisher
- SLACK, Inc.
- Published
- 1994-05
- Volume
- 17
- Issue
- 5
- Pages
- 445-448
- ISSN
- 0147-7447 (ISSN-L)
- 1938-2367
- OpenAlex
- W2249500842
- Cited by
- 109
- References
- 0
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.