Biomechanics of the Cornea and Wavefront-guided Laser Refractive Surgery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: Wavefront-guided laser refractive surgery induces postoperative optical aberrations that are not explained by the ablation profile. METHODS: A conceptual model is presented for a potential mechanism of surgically-induced corneal shape change that is dependent on structural modification, rather than ablation profile. RESULTS: Examples are provided from clinical and basic studies that are consistent with the proposed model. CONCLUSION: Corneal biomechanical response to ablative surgery may significantly affect outcomes, and should be taken into account when planning customized procedures. [J Refract Surg 2002;18:S589-S592]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical response to LASIK surgery for myopia from total and corneal aberration measurements.
Marcos, S. C., Barbero, S., Llorente, L., & Merayo-Llovés, J. (2001) · PubMed · Cited by 282
Effect of Acute Biomechanical Changes on Corneal Curvature After Photokeratectomy
Dupps, W. J., & Roberts, C. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20011101-05 · Cited by 212
Self-citationKatsube, N., Wang, R., Okuma, E., & Roberts, C. J. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20020901-19 · Cited by 28
Self-citation
Cited by
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Self-citationBiomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Corneal Biomechanics and Biomaterials
Ruberti, J. W., Sinha Roy, A., & Roberts, C. J. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105243 · Cited by 241
Self-citationEliasy, A., Chen, K.-J., Vinciguerra, R., Lopes, B. T., Abass, A., Vinciguerra, P., Ambrósio Jr., R., Roberts, C. J., & Elsheikh, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00105 · Cited by 221
“, 2015), 62 refractive surgery planning (Roberts, 2002;Pepose et al., 2007), keratoconus risk profiling 63 (Ortiz et al.”
BackgroundSelf-citationLASIK and PRK in hyperopic astigmatic eyes: is early retreatment advisable?
Frings, A., Richard, G., Steinberg, J., Linke, S., Katz, T., & Druchkiv, V. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s99098 · Cited by 29
“Powered by TCPDF (www.tcpdf.org) remodulation, 13 biomechanical changes, 14 and variation in the laser ablation depth per pulse across the treatment area in relation to corneal curvature.”
Metadata
- Authors
- Roberts, C.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2002-09
- Volume
- 18
- Issue
- 5
- Pages
- S589-92
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2400498618
- Cited by
- 171
- References
- 3
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.