Implantation of modular photovoltaic subretinal prosthesis
Open accessAbstract
BACKGROUND AND OBJECTIVE: Establish the surgical procedure for subretinal implantation of multiple photovoltaic arrays for the restoration of sight. MATERIALS AND METHODS: Multiple silicon photovoltaic arrays of 1 mm in diameter and 30 µm in thickness were implanted subretinally via single retinotomy in rabbits. Ophthalmoscopic imaging and optical coherence tomography (OCT) were used to validate the implants' placement. RESULTS: Vitrectomy, followed by subretinal fluid injection for retinal detachment and retinotomy, allowed accurate placement of seven modules in the bleb, covering approximately a 3.5-mm diameter area on the retina via a single 1.5-mm retinotomy. OCT confirmed complete reattachment of the retina over the implants. CONCLUSION: Subretinal implantation of multiple photovoltaic arrays via a single retinotomy, followed by their tiling, minimizes the scleral and retinal incisions and provides better fit to the spherical shape of the eye ball, compared to a single, larger module. Such minimally traumatic procedure can be performed with 20-gauge intraocular instruments.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Multiple PRIMA devices have been placed in the rabbit eye to increase the visual angle.
“Multiple PRIMA devices have been placed in the rabbit eye to increase the visual angle [123].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [123]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 9 · Cited by 30
- Authors
- Lee, D. Y., Lorach, H., Huie, P., & Palanker, D.
- Affiliations
- Gachon University Gil Medical Center (KR)
- Corresponding author
- Lorach, Henri
- Venue
- Ophthalmic Surgery, Lasers and Imaging Retina
- Publisher
- SLACK, Inc.
- Published
- 2016-02
- Volume
- 47
- Issue
- 2
- Pages
- 171-174
- ISSN
- 1542-8877 (ISSN-L)
- 2325-8160
- 2325-8179
- PMC
- PMC6492552
- OpenAlex
- W2263889128
- Cited by
- 30
- References
- 9
- Citations by year
- 2025: 3 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 7 · 2019: 2 · 2018: 5 · 2017: 1 · 2016: 3
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Ophthalmic surgery, lasers & imaging retina (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Defense (W81XWH-15–1-, W81XWH, W81XWH1510009)
- National Institutes of Health (W81XWH)
- National Eye Institute (R01-EY-18608, R01EY018608)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
- Keywords
- retinotomy, vitrectomy, retinal detachment, optical coherence tomography, rabbit model, vision restoration, minimally invasive surgery
- MeSH terms
- Animals, Electrodes, Implanted, Electric Stimulation Therapy, Microelectrodes, Rabbits, Retina, Retinal Detachment, Vitrectomy, Prosthesis Implantation, Tomography, Optical Coherence, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review