Cited by 30Neuroscience and Neural EngineeringRetinal and Macular SurgeryRetinal Development and Disorders

Implantation of modular photovoltaic subretinal prosthesis

Open access
Lee, Dae Yeong, Lorach, Henri, Huie, Phil, Palanker, Daniel·2016·Ophthalmic Surgery, Lasers and Imaging Retina

Abstract

BACKGROUND AND OBJECTIVE: Establish the surgical procedure for subretinal implantation of multiple photovoltaic arrays for the restoration of sight. MATERIALS AND METHODS: Multiple silicon photovoltaic arrays of 1 mm in diameter and 30 µm in thickness were implanted subretinally via single retinotomy in rabbits. Ophthalmoscopic imaging and optical coherence tomography (OCT) were used to validate the implants' placement. RESULTS: Vitrectomy, followed by subretinal fluid injection for retinal detachment and retinotomy, allowed accurate placement of seven modules in the bleb, covering approximately a 3.5-mm diameter area on the retina via a single 1.5-mm retinotomy. OCT confirmed complete reattachment of the retina over the implants. CONCLUSION: Subretinal implantation of multiple photovoltaic arrays via a single retinotomy, followed by their tiling, minimizes the scleral and retinal incisions and provides better fit to the spherical shape of the eye ball, compared to a single, larger module. Such minimally traumatic procedure can be performed with 20-gauge intraocular instruments.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/23258160-20160126-11

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 9 · Cited by 30

Authors
Lee, D. Y., Lorach, H., Huie, P., & Palanker, D.
Affiliations
Gachon University Gil Medical Center (KR)
Corresponding author
Lorach, Henri
Venue
Ophthalmic Surgery, Lasers and Imaging Retina
Publisher
SLACK, Inc.
Published
2016-02
Volume
47
Issue
2
Pages
171-174
ISSN
  • 1542-8877 (ISSN-L)
  • 2325-8160
  • 2325-8179
OpenAlex
W2263889128
Cited by
30
References
9
Citations by year
2025: 3 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 7 · 2019: 2 · 2018: 5 · 2017: 1 · 2016: 3
FWCI
2.06
Type
journal article
Language
en
Open access
Locations
  • Ophthalmic surgery, lasers & imaging retina (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • U.S. Department of Defense (W81XWH-15–1-, W81XWH, W81XWH1510009)
  • National Institutes of Health (W81XWH)
  • National Eye Institute (R01-EY-18608, R01EY018608)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
Keywords
retinotomy, vitrectomy, retinal detachment, optical coherence tomography, rabbit model, vision restoration, minimally invasive surgery
MeSH terms
Animals, Electrodes, Implanted, Electric Stimulation Therapy, Microelectrodes, Rabbits, Retina, Retinal Detachment, Vitrectomy, Prosthesis Implantation, Tomography, Optical Coherence, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review