The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types
Open accessAbstract
To investigate the influence of different fabrication methods of three-unit reinforced polyetheretherketone composite (PEEK/C) fixed dental prostheses (FDPs) on fracture load. Forty-five three-unit anatomically supported PEEK/C FDPs were fabricated as follows: i. milled using a CAD/CAM system from an industrially fabricated PEEK/C blank, ii. pressed from industrially fabricated PEEK/C pellets, and iii. pressed from granular PEEK/C. Fracture load was measured and data were statistically analysed (p<0.05). CAD/CAM fabricated FDPs (2,354 N) presented a higher mean fracture load than those pressed from granular PEEK/C material (1,738 N) (p<0.001). CAD/CAM milled FDPs and those pressed from PEEK/C-pellets showed spontaneous and brittle fractures near the pontic without deformation of the FDP. In contrast, granulate pressed FDPs showed some plastic deformation without fracture. CAD/CAM fabricated FDPs, and FDPs pressed from PEEK/C pellets showed higher Weibull moduli compared to FDPs pressed in granular form. Industrial pre-pressing of blanks (CAD/CAM/pellet) increased the stability and reliability of PEEK restorations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shock absorbing behavior of five restorative materials used on implants
Gracis, S. E., Nicholls, J. I., Chalupnik, J. D., & Yuodelis, R. A. (1992) · Implant Dentistry · doi:10.1097/00008505-199200110-00016 · Cited by 64
Cited by
Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb, S., Zafar, M. S., Khurshid, Z., & Siddiqui, F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2015.10.001 · Cited by 897
Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses
Alqurashi, H., Khurshid, Z., Syed, A. U. Y., Rashid Habib, S., Rokaya, D., & Zafar, M. S. (2021) · Journal of Advanced Research · doi:10.1016/j.jare.2020.09.004 · Cited by 300
The use of PEEK in digital prosthodontics: A narrative review
Papathanasiou, I., Kamposiora, P., Papavasiliou, G., & Ferrari, M. (2020) · BMC Oral Health · doi:10.1186/s12903-020-01202-7 · Cited by 279
Metadata
- Authors
- STAWARCZYK, B., EICHBERGER, M., UHRENBACHER, J., WIMMER, T., EDELHOFF, D., & SCHMIDLIN, P. R.
- Venue
- Dental Materials Journal
- Published
- 2015
- Volume
- 34
- Issue
- 1
- Pages
- 7-12
- ISSN
- 0287-4547 (ISSN-L)
- 1881-1361
- OpenAlex
- W1985165519
- Cited by
- 183
- References
- 1
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types. https://app.cochat.ai/papers/10.4012/dmj.2013-345
- The paper
- STAWARCZYK, B., EICHBERGER, M., UHRENBACHER, J., WIMMER, T., EDELHOFF, D., & SCHMIDLIN, P. R. (2015). Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types. Dental Materials Journal. https://doi.org/10.4012/dmj.2013-345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.