Wearable Biosensors for Monitoring Wound Healing
Open accessThe DOI matches its Crossref record.
Abstract
Continuous health monitoring often requires hospitalization, which can become an expensive and inconvenient choice for the patient. In this perspective, wearable sensors that allow in situ biosensing constitute a very promising technology. This work aims to develop immunosensors for continuous monitoring of the wound healing process, based on pH changes, as well as on the concentrations of inflammatory proteins such as the C-reactive protein (CRP). Sensing principles include the use of responsive hydrogels that swell in response to changes in the surroundings, and the use of functional surfaces that specifically recognize the target protein. The detection principle is based on an optical signal, using the evanescent field of light propagating along a waveguide, probing refractive index changes. An optical sensing system that can be integrated in a wound dressing patch has been designed, including a white light source (LED), and a spectrometer for detection. The sensor was successfully tested in the laboratory with biological samples (blood serum), demonstrating reversible pH measurements between pH 6-8, and detection of changes in the concentration of CRP between 1 and 100 μg/ml. The sensor will later be integrated into wound dressings or bandages, forming a sensing patch that is connected via optical fibres and electrical wires to the detection system and power supply. This novel technology will be particularly valuable in applications such as the supervision of skin grafts and ulcer treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
A review of stimuli-responsive shape memory polymer composites
Meng, H., & Li, G. (2013) · Polymer · doi:10.1016/j.polymer.2013.02.023 · Cited by 1,190
A survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
Towards fog-driven IoT eHealth: Promises and challenges of IoT in medicine and healthcare
Farahani, B., Firouzi, F., Chang, V., Badaroglu, M., Constant, N., & Mankodiya, K. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2017.04.036 · Cited by 983
A review of stimuli-responsive polymers for smart textile applications
Hu, J., Meng, H., Li, G., & Ibekwe, S. I. (2012) · Smart Materials and Structures · doi:10.1088/0964-1726/21/5/053001 · Cited by 639
Metadata
- Authors
- Pasche, S., Angeloni, S., Ischer, R., Liley, M., Luprano, J., & Voirin, G.
- Venue
- Advances in Science and Technology
- Publisher
- Trans Tech Publications Ltd
- Published
- 2008-09-02
- Volume
- 57
- Pages
- 80-87
- ISSN
- 1661-819X (ISSN-L)
- 1662-0356
- OpenAlex
- W2022473400
- Cited by
- 60
- References
- 0
- FWCI
- 3.79
- Type
- conference paper
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Biosensors for Monitoring Wound Healing. https://app.cochat.ai/papers/10.4028/www.scientific.net/ast.57.80
- The paper
- Pasche, S., Angeloni, S., Ischer, R., Liley, M., Luprano, J., & Voirin, G. (2008). Wearable Biosensors for Monitoring Wound Healing. Advances in Science and Technology. https://doi.org/10.4028/www.scientific.net/ast.57.80
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.