CoChat

An Efficiency Evaluation of Protocols for Tight Glycemic Control in Intensive Care Units

Malesker, Mark A., Foral, Pamela A., McPhillips, Ann C., Christensen, Keith J., Chang, Julie A., Hilleman, Daniel E. · 2007 · American Journal of Critical Care
Cited by 52

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background The efficiency of protocols for tight glycemic control is uncertain despite their adoption in hospitals. Objectives To evaluate the efficiency of protocols for tight glycemic control used in intensive care units. Methods Three separate studies were performed: (1) a third-party observer used a stopwatch to do a time-motion analysis of patients being treated with a protocol for tight glycemic control in 3 intensive care units, (2) charts were retrospectively reviewed to determine the frequency of deviations from the protocol, and (3) a survey assessing satisfaction with and knowledge of the protocol was administered to full-time nurses. Results Time-motion data were collected for 454 blood glucose determinations from 38 patients cared for by 47 nurses. Mean elapsed times from blood glucose result to therapeutic action were 2.24 (SD, 1.67) minutes for hypoglycemia and 10.65 (SD, 3.24) minutes for hyperglycemia. Mean elapsed time to initiate an insulin infusion was 32.56 (SD, 12.83) minutes. Chart review revealed 734 deviations from the protocol in 75 patients; 57% (n = 418) were deviations from scheduled times for blood glucose measurements. The mean number of deviations was approximately 9 per patient. Of 60 nurses who responded to the workload survey, 42 (70%) indicated that the protocol increased their workload; frequency of blood glucose determinations was the most common reason. Conclusions Nurses spend substantial time administering protocols for tight glycemic control, and considerable numbers of deviations occur during that process. Further educational efforts and ongoing assessment of the impact of such protocols are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4037/ajcc2007.16.6.589

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 52

Metadata

Authors
Malesker, M. A., Foral, P. A., McPhillips, A. C., Christensen, K. J., Chang, J. A., & Hilleman, D. E.
Venue
American Journal of Critical Care
Published
2007-11-01
Volume
16
Issue
6
Pages
589-598
ISSN
  • 1062-3264 (ISSN-L)
  • 1937-710X
OpenAlex
W2160766334
Cited by
52
References
3
FWCI
3.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Efficiency Evaluation of Protocols for Tight Glycemic Control in Intensive Care Units. https://app.cochat.ai/papers/10.4037/ajcc2007.16.6.589
The paper
Malesker, M. A., Foral, P. A., McPhillips, A. C., Christensen, K. J., Chang, J. A., & Hilleman, D. E. (2007). An Efficiency Evaluation of Protocols for Tight Glycemic Control in Intensive Care Units. American Journal of Critical Care. https://doi.org/10.4037/ajcc2007.16.6.589

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.