Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record.

Heterogeneity among T cells in intracellular free calcium responses after mitogen stimulation with PHA or anti-CD3. Simultaneous use of indo-1 and immunofluorescence with flow cytometry.

Rabinovitch, P S, June, C H, Grossmann, A, Ledbetter, J A·1986·The Journal of Immunology

Abstract

Measurement of intracellular ionized calcium concentrations ([Ca2+]i) has been indispensable in elucidating the central role of [Ca2+]i as a trigger of cellular responses to activating stimuli. Such studies have employed the dye quin2, which has not been readily adapted to analysis of individual small cells. We show here that the calcium response of large numbers of single cells can be analyzed with the use of flow cytometry and the recently described dye, indo-1. Such analyses demonstrate for the first time the heterogeneous nature of the [Ca2+]i response to mitogenic stimuli within populations of peripheral blood lymphocytes (PBL). By simultaneous quantitation of one- or two-color surface immunofluorescence labels, some of this heterogeneity of [Ca2+]i response in PBL is shown to be related to cellular immunophenotype. Almost all T cells responded to anti-CD3 antibody; however, the response is greater among CD4+ than CD8+ cells, and within the CD4+ population the rate of response to stimulation by antibody to CD3 differed between subpopulations defined by expression of the common leukocyte marker p220. In contrast, not all T cells responded to phytohemagglutinin (PHA), even at very high doses. As with anti-CD3, after stimulation with PHA, CD4+ cells showed a larger proportion of responding cells than did CD8+ cells. In separate experiments, indo-1 was found not to impair reproductive viability of PBL, thereby providing the potential for analysis of functional activity after the separation of cells by sorting on the basis of the [Ca2+]i response to stimuli. Mixing experiments indicated that a response of a subpopulation representing as little as 0.3% of total cells could be readily detected. Thus, the flow cytometric assay with indo-1 is the first technique that allows the quantitative analysis of response differences of small subpopulations of cells and intercellular variation in [Ca2+]i.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4049/jimmunol.137.3.952

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 362

Metadata

Authors
Rabinovitch, P. S., June, C. H., Grossmann, A., & Ledbetter, J. A.
Venue
The Journal of Immunology
Published
1986-08-01
Volume
137
Issue
3
Pages
952-961
ISSN
  • 0022-1767 (ISSN-L)
  • 1550-6606
OpenAlex
W1662473501
Cited by
362
References
0
FWCI
10.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heterogeneity among T cells in intracellular free calcium responses after mitogen stimulation with PHA or anti-CD3. Simultaneous use of indo-1 and immunofluorescence with flow cytometry. https://app.cochat.ai/papers/10.4049/jimmunol.137.3.952
The paper
Rabinovitch, P. S., June, C. H., Grossmann, A., & Ledbetter, J. A. (1986). Heterogeneity among T cells in intracellular free calcium responses after mitogen stimulation with PHA or anti-CD3. Simultaneous use of indo-1 and immunofluorescence with flow cytometry. The Journal of Immunology. https://doi.org/10.4049/jimmunol.137.3.952

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.