The DOI matches its Crossref record.
Quantitative Determination of Serum Immunoglobulins in Antibody-Agar Plates
Abstract
Summary: The antibody in agar plate test has proved valuable for the quantitative measurement of individual serum immunoglobulins. With this technique, specific antiserum is mixed uniformly in an agar gel plate. Antigen containing solutions are placed in small antigen wells cut in the agar. A concentric ring of antigen: antibody precipitate forms around the antigen well. By graphically comparing the ring diameters with those of appropriate standards, the protein concentration of the test sera can be determined. The probable error in measurement of normal serum immunoglobulins is ±10%. This procedure has been used to quantify protein concentrations as low as 0.003 mg/ml. Multiple samples can be easily tested and less than 0.1 ml of sample is required. The mean immunoglobulin levels in 20 normal human sera were found to be 12.4 mg/ml for IgG (7 S γ2-globulins); 2.8 mg/ml for IgA (γ1A or β2A-globulins) and 1.23 mg/ml for the IgM (18 S γ1M-globulins). Type K (I) and Type L (II) immunoglobulins were similarly determined. The results by the antibody-agar plate method are similar to those obtained by the isotopic immune inhibition technique, except for the serum IgA and Type K (I) and Type L (II) immunoglobulin levels. With each of these proteins the values obtained by the isotopic immune inhibition test are higher than those found by the antibody-agar plate test. The basis for this difference is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elevation of Cord over Maternal IgG Immunoglobulin: Evidence for an Active Placental IgG Transport
KOHLER, P. F., & FARR, R. S. (1966) · Nature · doi:10.1038/2101070a0 · Cited by 325
The isolation and bacteriostatic properties of lactoferrin from bovine milk whey
Law, B. A., & Reiter, B. (1977) · Journal of Dairy Research · doi:10.1017/s0022029900020550 · Cited by 139
Fetal and maternal immunoglobulin levels during pregnancy
Gusdon, J. P. (1969) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)34434-9 · Cited by 81
Serum protein levels in primary biliary cirrhosis
MacSween, R. N. M., Horne, C. H. W., Moffat, A. J., & Hughes, H. M. (1972) · Journal of Clinical Pathology · doi:10.1136/jcp.25.9.789 · Cited by 29
Ibeziako, P. A., & Williams, A. I. O. (1980) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1980.tb04461.x · Cited by 23
Metadata
- Authors
- Fahey, J. L., & McKelvey, E. M.
- Venue
- The Journal of Immunology
- Publisher
- Oxford University Press (OUP)
- Published
- 1965-01-01
- Volume
- 94
- Issue
- 1
- Pages
- 84-90
- ISSN
- 0022-1767 (ISSN-L)
- 1550-6606
- OpenAlex
- W1502953431
- Cited by
- 1,528
- References
- 0
- FWCI
- 132.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Determination of Serum Immunoglobulins in Antibody-Agar Plates. https://app.cochat.ai/papers/10.4049/jimmunol.94.1.84
- The paper
- Fahey, J. L., & McKelvey, E. M. (1965). Quantitative Determination of Serum Immunoglobulins in Antibody-Agar Plates. The Journal of Immunology. https://doi.org/10.4049/jimmunol.94.1.84
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.