Interrater Reliability of the Star Excursion Balance Test
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Context: Dynamic postural control has gained popularity as a more useful assessment of function than static postural control. One measurement of dynamic postural control that has increased in frequency of use is the Star Excursion Balance Test (SEBT). Although the intrarater reliability of the SEBT is excellent, few authors have determined interrater reliability. Preliminary evidence has shown poor reliability between assessors. Objective: To determine interrater reliability using a group of investigators at 2 testing sites. A corollary purpose was to examine the interrater reliability when using normalized and nonnormalized performance scores on the SEBT. Design: Descriptive laboratory study. Setting: University research laboratory. Patients or Other Participants: A total of 29 healthy participants between 18 and 50 years of age. Intervention(s): Participants were evaluated by 5 raters at 2 testing sites. After participants performed 4 practice trials, each rater assessed 3 test trials in the anterior, posteromedial, and posterolateral reaching directions of the SEBT. Main Outcome Measure(s): Normalized and nonnormalized (leg-length) reaching distances were analyzed. Additionally, the mean and maximum values from the 3 test trials were analyzed, producing a total of 16 variables. Results: For all 16 measures, the interrater reliability was excellent. For the normalized maximum excursion distances, the intraclass correlation coefficients (1,1) ranged from 0.86 to 0.92. Reliability for the nonnormalized measurements was stronger, ranging from 0.89 to 0.94. Conclusions: When the raters have been trained by an experienced rater, the SEBT is a test with excellent reliability when used across multiple raters in different settings. This information adds to the body of knowledge that exists regarding the usefulness of the SEBT as an assessment tool in clinical and research practice. Establishing excellent interrater reliability with normalized and nonnormalized scores strengthens the evidence for using the SEBT, especially at multiple sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Reliability of the PEDro Scale for Rating Quality of Randomized Controlled Trials
Maher, C. G., Sherrington, C., Herbert, R. D., Moseley, A. M., & Elkins, M. (2003) · Physical Therapy · doi:10.1093/ptj/83.8.713 · Cited by 4,808 · cited 1×
“Using an ICC (1,1) model, we examined the reliability of a single assessment by a rater, wherein different sets of raters assessed different groups of participants.(13,23,24) The interrater reliability of the SEBT was determined by calculating ICCs (1,1) with 95% confidence intervals for each of the 4 primary variable…”
MethodPlisky, P. J., Rauh, M. J., Kaminski, T. W., & Underwood, F. B. (2006) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2006.2244 · Cited by 1,414 · cited 1×
“Although the SEBT consists of 8 directions, conventional testing procedures have adopted a condensed version of the test, using the ANT (Figure 1), PM (Figure 2), and PL (Figure 3) reaching directions.(11,18,22) For the ANT reach, the stance-foot position is to place the toes at the 0 mark position of the anterior-rea…”
MethodOlmsted, L. C., Carcia, C. R., Hertel, J. N., & Shultz, S. J. (2002) · PubMed Central · Cited by 727
Hertel, J. N., Braham, R. A., Hale, S. A., & Olmsted, L. C. (2006) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2006.36.3.131 · Cited by 632
Considerations for Normalizing Measures of the Star Excursion Balance Test
Gribble, P. A., & Hertel, J. (2003) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0702_3 · Cited by 600 · cited 13×
“One purpose of our investigation was to establish the interrater reliability using the normalized procedures that are now standard for the SEBT.19 Both normalized and nonnormalized reaching distances were associated with stronger interrater reliability than previously reported.14 Again, this is likely because we affor…”
BackgroundMethodInfluentialSelf-citationThe Reliability of the Star-Excursion Test in Assessing Dynamic Balance
Kinzey, S. J., & Armstrong, C. W. (1998) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1998.27.5.356 · Cited by 499 · cited 1×
“87.(15) Hertel et al(14) recruited 16 healthy women who performed all 8 directions of SEBT over 2 testing sessions, with 2 investigators evaluating each participant on each day.”
BackgroundIntratester and Intertester Reliability during the Star Excursion Balance Tests
Hertel, J., Miller, S. J., & Denegar, C. R. (2000) · Journal of Sport Rehabilitation · doi:10.1123/jsr.9.2.104 · Cited by 467 · cited 4×
“Although the intrarater reliability of the SEBT is excellent, few investigators have determined interrater reliability; preliminary evidence is for poor reliability between assessors.(14) Plisky et al(18) showed that the SEBT may be a useful, inexpensive tool to screen athletes for risk of lower extremity musculoskele…”
BackgroundResultInfluentialBalance Training Improves Function and Postural Control in Those with Chronic Ankle Instability
MCKEON, P. O., INGERSOLL, C. D., KERRIGAN, D. C., SALIBA, E., BENNETT, B. C., & HERTEL, J. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31817e0f92 · Cited by 443 · cited 2×
“Additionally, the SEBT can assess improvements in dynamic postural control after exercise interventions.(4,11,12) The limited literature available suggests that when a single investigator performs the assessments and the participant has had an adequate number of practice trials, the conventional categorization of reli…”
BackgroundMethod
Cited by
Powden, C. J., Dodds, T. K., & Gabriel, E. H. (2019) · International Journal of Sports Physical Therapy · doi:10.26603/ijspt20190683 · Cited by 191
Metadata
- Authors
- Gribble, P. A., Kelly, S. E., Refshauge, K. M., & Hiller, C. E.
- Venue
- Journal of Athletic Training
- Published
- 2013-10-01
- Volume
- 48
- Issue
- 5
- Pages
- 621-626
- ISSN
- 1062-6050 (ISSN-L)
- OpenAlex
- W2056866605
- Cited by
- 222
- References
- 19
- FWCI
- 27.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interrater Reliability of the Star Excursion Balance Test. https://app.cochat.ai/papers/10.4085/1062-6050-48.3.03
- The paper
- Gribble, P. A., Kelly, S. E., Refshauge, K. M., & Hiller, C. E. (2013). Interrater Reliability of the Star Excursion Balance Test. Journal of Athletic Training. https://doi.org/10.4085/1062-6050-48.3.03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.